Performance of a modified built-middle photovoltaic-thermocatalytic Trombe wall system by fins

被引:3
|
作者
Xiao, Lan [1 ,2 ]
Zhang, Yu-Qing [2 ]
Wu, Shuang-Ying [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Sch Energy & Power Engn, Chongqing 400044, Peoples R China
关键词
Photovoltaic; Thermocatalytic; Trombe wall; Vertical fins; Thermodynamic performance; VENETIAN BLIND; ENERGY; SIMULATION; PARAMETERS; OXIDATION; COLLECTOR; EXERGY;
D O I
10.1016/j.applthermaleng.2024.123124
中图分类号
O414.1 [热力学];
学科分类号
摘要
The photovoltaic-thermocatalytic Trombe wall is attracting attention due to the ability to generate electricity, heat and purify indoor air, while it has the disadvantages of low electrical and degradation performance. Also the overall performance evaluation method of multi -functional Trombe walls still needs to be further improved. To fill these gaps, a modified built -middle photovoltaic-thermocatalytic Trombe wall by vertical fins was proposed in this study. Based on the first and second laws of thermodynamics, the effects of fins spacing and fins height under different solar radiation intensities on the performance were investigated by numerical simulation method. In addition, the performance of this modified system was compared with other relevant systems. The results reveal that the existence of an optimal fins spacing or fins height can maximize the thermal efficiency. The narrower fins spacing and higher fins can enhance electrical efficiency and degradation rate. Without sacrificing or even improving thermal performance, the presence of fins with suitable structural parameters leads to higher electrical and purification performance. Compared with the system with no fins, when the solar radiation intensity is 400 W/m 2 and 800 W/m 2 respectively, the thermal efficiency, electrical efficiency, degradation rate, and overall exergy efficiency gain relative enhancements of 1.81 % and 2.71 %, 2.47 % and 5.18 %, 2.27 times and 2.19 times, and 3.53 % and 6.67 %; and the overall exergy efficiency reaches 12.26 % and 12.20 % at the fins spacing of 31.25 mm and fins height of 30 mm. The introduction of exergy concept provides an effective way for overall performance evaluation of multi -functional Trombe walls with different grades of energies (products). The obtained thermal exergy and electrical exergy dominate the overall exergy efficiency, and the diffusion exergy accounts for a negligible proportion due to the relatively low concentration of pollutant. In comparison with other relevant systems, the modified system shows the best comprehensive utilization of solar energy, and has great application potential. This study provides a new direction for the performance improvement and assessment of multi -functional Trombe wall systems.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Experimental and numerical study on the performance of a built-middle PV Trombe wall system
    Lin, Yuan
    Ji, Jie
    Zhou, Fan
    Ma, Yang
    Luo, Kun
    Lu, Xiangyou
    ENERGY AND BUILDINGS, 2019, 200 : 47 - 57
  • [2] Experimental and numerical study on the performance of a built-middle PV Trombe wall system
    Yuan Lin
    Jie Ji
    Fan Zhou
    侯恩哲
    建筑节能, 2019, 47 (10) : 145 - 145
  • [3] Thermal and electrical behavior of built-middle photovoltaic integrated Trombe wall: Experimental and numerical study
    Lin, Yuan
    Ji, Jie
    Lu, Xiangyou
    Luo, Kun
    Zhou, Fan
    Ma, Yang
    ENERGY, 2019, 189
  • [4] Numerical Simulation on Performance of Finned-Built-Middle Photovoltaic Trombe Wall
    Xiao, Lan
    Zhang, Yuqing
    Wu, Shuangying
    Xu, Shijie
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (07): : 1917 - 1923
  • [5] Numerical Simulation of Partially-covered and Built-out Photovoltaic-thermocatalytic-Trombe Wall Performance
    Xiao, Lan
    Zhang, Yuqing
    Wu, Shuangying
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (12): : 3193 - 3198
  • [6] Effects of the PCM layer position on the comprehensive performance of a built-middle PV-Trombe wall system for building application in the heating season
    Ke, Wei
    Ji, Jie
    Zhang, Chengyan
    Xie, Hao
    Tang, Yayun
    Wang, Chuyao
    ENERGY, 2023, 267
  • [7] Modeling of Natural Ventilation in built-in photovoltaic-Trombe wall
    Xu, Xiaowei
    Su, Yaxin
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1537 - 1541
  • [8] Numerical and experimental study on the performance of a Photovoltaic Trombe wall system with Venetian blinds
    Islam, Nazrul
    Irshad, Kashif
    Zahir, Md Hasan
    Islam, Saiful
    ENERGY, 2021, 218 (218)
  • [9] Performance comparison of multi-functional photovoltaic-Trombe wall with and without fins and their impacts on the removal of indoor infectious bioaerosols
    Qian, Yu
    Ji, Jie
    Xie, Hao
    Jia, Hengmin
    Meng, Hongju
    Li, Jiyao
    Mu, Yan
    SOLAR ENERGY, 2024, 282
  • [10] Enhancement of the performance of Photovoltaic/Trombe wall system using the porous medium: Experimental and theoretical study
    Ahmed, Omer K.
    Hamad, Khalaf I.
    Salih, Abdulrazzaq M.
    ENERGY, 2019, 171 : 14 - 26