A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana

被引:0
|
作者
Kyei, Kofi Adesi [1 ,2 ]
Daniels, Joseph [2 ]
Adom, Ameyaw Kwame [2 ]
Odonkor, Philip [2 ]
Nyantakyi, Andrew Yaw [2 ]
Adjabu, Dorothy Ekua [3 ]
机构
[1] Univ Ghana, Dept Radiog, KB 143, Legon, Ghana
[2] Korle Bu Teaching Hosp, Natl Ctr Radiotherapy Oncol & Nucl Med, KB 369, Accra, Ghana
[3] Univ Ghana, Sch Biomed & Allied Hlth, Dept Physiotherapy, KB 143, Accra, Ghana
来源
ECANCERMEDICALSCIENCE | 2024年 / 18卷
关键词
radiotherapy; 3-D conformal radiotherapy; intensity-modulated radiotherapy; conformity index; homogeneity index; dosimetric evaluation; TOMOTHERAPY; RADIATION; ARC;
D O I
10.3332/ecancer.2024.1707
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
External beam radiotherapy incorporates treatment techniques such as three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), image-guided radiotherapy and volumetric modulated arc therapy to deliver high-energy radiation to cancer. The use of IMRT for cancer treatment is also associated with significant costs for patients in low-middle-income countries. The purpose of this study was to compare the dosimetric properties of 3DCRT and IMRT treatment plans for the external beam irradiation of patients with prostate cancer (Pca) to ascertain the superiority of IMRT in terms of dose homogeneity, conformity and dose limitation to organs at risk (OAR) in a resource-limited setting. One hundred and sixty treatment plans for 80 patients were created using 3DCRT and IMRT on the Eclipse treatment planning system (version 13.6). Data were collected and assessed from the dose -volume histogram of each plan. The conformity and homogeneity index (HI) for each of the plans were calculated. The doses to the OAR were also recorded and evaluated. The mean HIs for the IMRT and 3DCRT treatment techniques were 0.04 +/- 0.02 (range: 0.01-0.011) and 0.09 +/- 0.02 (range: 0.04-0.016), respectively. The mean conformity index (CI) for IMRT and 3DCRT techniques were 1.257 +/- 0.112 (range: 0.99-1.58) and 1.302 +/- 0.196 (range: 1.10-2.26). IMRT had a better significant mean HI and CI compared to 3DCRT. Generally, for this study, IMRT had better organ sparing compared to 3DCRT. The mean doses for the OARs ranged from 4.3-74.6 Gy for IMRT and 3.1-75.9 Gy for the 3DCRT technique. Overall, this study demonstrates that IMRT may offer an enhanced therapeutic profile, potentially reducing toxicity to the patient and ensuring more precise dose delivery to the target volume compared to 3DCRT in PCa external beam irradiation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer
    Adeneye, Samuel
    Akpochafor, Michael
    Habeebu, Muhammad
    Omojola, Akintayo
    Joseph, Adedayo
    Awhariado, John
    Durosinnmi-Etti, Abayomi
    Aweda, Moses
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 104 - 111
  • [2] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196
  • [3] Dosimetric effect of Elekta Beam Modulator micromultileaf in three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer
    Carosi, Alessandra
    Ingrosso, Gianluca
    Ponti, Elisabetta
    Tolu, Barbara
    Murgia, Alessandra
    di Cristino, Daniela
    Santoni, Riccardo
    MEDICAL DOSIMETRY, 2014, 39 (02) : 180 - 184
  • [4] A dosimetric comparison of intensity modulated radiotherapy versus three-dimensional conformal radiotherapy for esophageal carcinoma
    Jiang, Z.
    Zhou, L.
    Jiang, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S268 - S268
  • [5] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [6] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [7] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [8] Postoperative radiotherapy for prostate cancer - evaluation of target motion and treatment technique (intensity modulated versus three-dimensional conformal radiotherapy)
    Siluschek, J.
    Pinkawa, M.
    Piroth, M. D.
    Gagel, B.
    Eble, M. J.
    EJC SUPPLEMENTS, 2005, 3 (02): : 242 - 242
  • [9] Dosimetric analysis of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy-step and shoot, helical tomotherapy, and volumetric modulated arc therapy in prostate cancer radiotherapy
    Gozal, Fenny
    Gondhowiardjo, Soehartati Argadikoesoema
    Kodrat, Henry
    Wibowo, Wahyu Edy
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) : 893 - 900
  • [10] A comparison of clinical outcomes between three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer
    Shimizuguchi, Takuya
    Nihei, Keiji
    Okano, Tomoyuki
    Machitori, Yumiko
    Ito, Kei
    Karasawa, Katsuyuki
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2017, 22 (02) : 373 - 379