Ultrasound-assisted ionic liquid based dispersive liquid-liquid microextraction and flame atomic absorption spectrometry of cobalt, copper, and zinc in environmental water samples

被引:86
|
作者
Rajabi, Maryam [1 ]
Asemipour, Somayeh [1 ]
Barfi, Behruz [1 ]
Jamali, Mohammad Reza [2 ]
Behzad, Mandi [1 ]
机构
[1] Semnan Univ, Dept Chem, Semnan 35195363, Iran
[2] Payame Noor Univ, Dept Chem, Tehran 193953697, Iran
关键词
Ultrasound-assisted ionic liquid-based dispersive liquid-liquid microextraction; Flame atomic absorption spectrometry; Copper; Cobalt; Zinc; Environmental water sample; SOLID-PHASE EXTRACTION; CLOUD POINT EXTRACTION; INTRODUCTION SYSTEM; FOOD SAMPLES; SOLVENT; PLASMA; PRECONCENTRATION; CADMIUM; OPTIMIZATION; SPECIATION;
D O I
10.1016/j.molliq.2014.01.026
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In the present study, the simultaneous preconcentration of copper, cobalt and zinc based on ultrasound-assisted ionic liquid-based dispersive liquid-liquid microextraction as a prior step to their determination by flame atomic absorption spectrometry was developed. Some effective parameters such as type and volume of extraction and dispersive solvents, concentration of complexing agent, pH of sample solution, salting out effect, and sonication time were studied and optimized. Under the optimal conditions (including extraction solvent: 1-hexyl-3-methylimidazolium hexafluorophosphate [HMIM][PF6]], 90 mg; dispersive solvent: acetone, 220 mu L; complexing agent: N,N'-bis(2-salicylaldiminato)-1,8-diamino-3,6-dioxaoctane, 4.0 x 10(-2) mol L-1; pH of sample: 6.5; without salt addition; and sonication time: 2 min), limits of detection (LODs), linear ranges (LRs), preconcentration factor (PF), enhancement factor (EF) and consumptive index (Cl) were ranging from 1.9 to 4.4 mu g L-1, 6 to 500 mu g L-1, 50,48 to 56, and 0.18 to 0.21 for these ions in the real samples, respectively. The suggested procedure was successfully applied for the determination of the copper, cobalt and zinc ions in environmental water samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 50 条
  • [1] Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples
    Li, Shengqing
    Cai, Shun
    Hu, Wei
    Chen, Hao
    Liu, Hanlan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) : 666 - 671
  • [2] Surfactant-based dispersive liquid-liquid microextraction for the determination of zinc in environmental water samples using flame atomic absorption spectrometry
    Shrivas, Kamlesh
    Dewangan, Khemchand
    Ahmed, Asar
    ANALYTICAL METHODS, 2016, 8 (27) : 5519 - 5525
  • [3] Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with Flame Atomic Absorption Spectrometry for Determination of Silver in Water Samples
    Abadi, M. Dehghani Mohammad
    Chamsaz, M.
    Arbab-Zavar, M. H.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (07) : 3984 - 3988
  • [4] Combination of dispersive liquid-liquid microextraction and flame atomic absorption spectrometry for preconcentration and determination of copper in water samples
    Khani, Rouhollah
    Shemirani, Farzaneh
    Majidi, Behrooz
    DESALINATION, 2011, 266 (1-3) : 238 - 243
  • [5] Comparison of ultrasound-assisted, surfactant-assisted and conventional dispersive liquid-liquid microextraction coupled with flame atomic absorption spectrometry for the determination of copper
    Wen, Xiaodong
    Fan, Min
    Yang, Deqing
    Li, Min
    Li, Chunyan
    Zhang, Yanyan
    ANALYTICAL METHODS, 2013, 5 (21) : 6030 - 6036
  • [6] Determination of Copper in Food and Water by Dispersive Liquid-Liquid Microextraction and Flame Atomic Absorption Spectrometry
    Al Othman, Zeid
    Unsal, Yunus Emre
    Habila, Mohamed
    Shabaka, Aza
    Tuzen, Mustafa
    Soylak, Mustafa
    ANALYTICAL LETTERS, 2015, 48 (11) : 1738 - 1750
  • [7] Ionic liquids versus ionic liquid-based surfactants in dispersive liquid-liquid microextraction for determining copper in water by flame atomic absorption spectrometry
    Ayala-Cabrera, Juan F.
    Trujillo-Rodriguez, Maria J.
    Pino, Veronica
    Hernandez-Torres, Oscar M.
    Afonso, Ana M.
    Sirieix-Plenet, Juliette
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (02) : 101 - 118
  • [8] Ligandless, Task-Specific Ionic Liquid-Based Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction for the Determination of Cobalt Ions by Electrothermal Atomic Absorption Spectrometry
    Stanisz, Ewa
    Werner, Justyna
    ANALYTICAL LETTERS, 2017, 50 (18) : 2884 - 2899
  • [9] Dispersive liquid-liquid microextraction combined with flame atomic absorption spectrometry for determination of cadmium in environmental, water and food samples
    Sanchez Rojas, F.
    Bosch Ojeda, C.
    Cano Pavon, J. M.
    ANALYTICAL METHODS, 2011, 3 (07) : 1652 - 1655
  • [10] Supramolecular Dispersive Liquid-Liquid Microextraction and Determination of Copper by Flame Atomic Absorption Spectrometry
    Luo, Tao
    Li, Yingtang
    Liu, Chang
    Liu, Mousheng
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (15) : 4835 - 4838