Early monitoring for 3D-printed patient-specific mandible reconstructive implant biomechanical behavior under different occlusal conditions using a wireless module system

被引:0
|
作者
Wu, Cheng-Hsien [1 ,2 ]
Wu, Hsiao-Kuan [3 ]
Tsai, Pei-Jung [4 ]
Lin, Chun-Li [5 ]
机构
[1] Taipei Vet Gen Hosp, Dept Stomatol, Oral & Maxillofacial Surg, Taipei, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Sch Dent, Dept Dent, Taipei, Taiwan
[3] Natl Taipei Univ Nursing & Hlth Sci, Dept Exercise & Hlth Sci, Taipei, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Dept Biomed Engn, Taipei, Taiwan
[5] Natl Yang Ming Chaio Tung Univ, Med Device Innovat & Translat Ctr, Dept Biomed Engn, Hsinchu, Taiwan
关键词
3D-printed implant; Wireless; Biomechanics; Patient-specific; Mandibular defect;
D O I
10.36922/ijb.2553
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional (3D) printing technology used to manufacture patient -specific, large-scale medical implants has become increasingly prevalent. Nevertheless, early biomechanics monitoring can enhance the implantation success rate. This study developed a wireless module system (WMS) for strain gauge measurement that can be placed within the implant to achieve early biomechanical behavior detection for an experimental 3D -printed metal model of a patient -specific segmental implant (MMPSI) after surgery. This WMS includes a chip, a circuit board, and a battery, all with dimensions smaller than 20 mm x 12 mm x 8 mm. This system can connect to strain gauges and interface with a mobile application for measuring and transmitting strain data. The WMS functionality was confirmed through cantilever beam experiments. Premature failure was detected using this WMS installed in an experimental 3D -printed MMPSI and through in vitro fatigue biomechanical testing under different occlusal forces applied on the plastic -simulated mandibular model. The WMS validation results indicated that the strain gauge measurement error compared to theoretical values was within 17%. Biomechanical fatigue results addressed the higher strain received and greater cyclic loads were recorded when occlusal force was applied onto the premolar under identical force application conditions because the premolar was closer to the strain gauge attachment location, resulting in a longer lever arm compared to the molar. This study concluded that the developed WMS for strain measurement can be installed in a patient -specific 3D -printed implant with enough internal space to detect early biomechanical behavior after surgery. Current results of in vitro fatigue test for segmental defect indicated that occlusal situation can be adjusted to reduce implantation failure risk.
引用
收藏
页码:604 / 617
页数:14
相关论文
共 50 条
  • [1] Reconstruction of mandible using a computer-designed 3D-printed patient-specific titanium implant: a case report
    Khaldoun Darwich
    Mohamad Bilal Ismail
    Mohammed Yamen Al-Shurbaji Al-Mozaiek
    Abdulhadi Alhelwani
    Oral and Maxillofacial Surgery, 2021, 25 : 103 - 111
  • [2] Reconstruction of mandible using a computer-designed 3D-printed patient-specific titanium implant: a case report
    Darwich, Khaldoun
    Ismail, Mohamad Bilal
    Al-Mozaiek, Mohammed Yamen Al-Shurbaji
    Alhelwani, Abdulhadi
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2021, 25 (01): : 103 - 111
  • [3] Secondary Mandibular Reconstruction with Patient-Specific 3D-Printed Implant
    Sharma, Neha
    Singh, Harsimran
    Goyal, Anish
    Malhotra, Mandeep Singh
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024, 23 (02): : 258 - 260
  • [4] Secondary Mandibular Reconstruction with Patient-Specific 3D-Printed Implant
    Neha Sharma
    Harsimran Singh
    Anish Goyal
    Mandeep Singh Malhotra
    Journal of Maxillofacial and Oral Surgery, 2024, 23 : 258 - 260
  • [5] Patient-specific 3D-printed shelf implant for the treatment of hip dysplasia: Anatomical and biomechanical outcomes in a canine model
    Willemsen, Koen
    Tryfonidou, Marianna
    Sakkers, Ralph
    Castelein, Rene M.
    Zadpoor, Amir A.
    Seevinck, Peter
    Weinans, Harrie
    Meij, Bjorn
    Wal, Bart C. H.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (05) : 1154 - 1162
  • [6] Numerical and experimental investigation of a 3D-printed PCU patient-specific cranial implant
    Gregorio Pisaneschi
    Mattia Mele
    Andrea Zucchelli
    Maurizio Fiorini
    Giampaolo Campana
    Emanuela Marcelli
    Achille Tarsitano
    Elisabetta Lucchi
    Laura Cercenelli
    Progress in Additive Manufacturing, 2024, 9 : 299 - 313
  • [7] Numerical and experimental investigation of a 3D-printed PCU patient-specific cranial implant
    Pisaneschi, Gregorio
    Mele, Mattia
    Zucchelli, Andrea
    Fiorini, Maurizio
    Campana, Giampaolo
    Marcelli, Emanuela
    Tarsitano, Achille
    Lucchi, Elisabetta
    Cercenelli, Laura
    PROGRESS IN ADDITIVE MANUFACTURING, 2024, 9 (02) : 299 - 313
  • [8] Patient-Specific 3D-Printed Miniplates for Free Flap Fixation at the Mandible: A Feasibility Study
    Kreutzer, Kilian
    Steffen, Claudius
    Koerdt, Steffen
    Doll, Christian
    Ebker, Tobias
    Nahles, Susanne
    Fluegge, Tabea
    Heiland, Max
    Beck-Broichsitter, Benedicta
    Rendenbach, Carsten
    FRONTIERS IN SURGERY, 2022, 9
  • [9] Early Results of a Patient-Specific Total Knee Arthroplasty Implant Cast From a 3D-Printed Mold
    Roy, Adam E.
    Mestriner, Alexandre Barbieri
    Antonelli, Brielle
    Ackermann, Jakob
    Chen, Antonia F.
    Lange, Jeffrey K.
    ARTHROPLASTY TODAY, 2024, 30
  • [10] Patient-specific miniplates versus patient-specific reconstruction plate: A biomechanical comparison with 3D-printed plates in mandibular reconstruction
    Steffen, Claudius
    Sellenschloh, Kay
    Willsch, Magdalena
    Soares, Ana Prates
    Morlock, Michael M.
    Heiland, Max
    Kreutzer, Kilian
    Huber, Gerd
    Rendenbach, Carsten
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 140