High-fidelity, low-cost synthetic training model for fetoscopic spina bifida repair

被引:2
|
作者
Ahmad, Mirza A. [1 ,2 ,3 ]
Watananirun, Kanokwaroon [2 ,3 ]
De Bie, Felix [2 ,3 ]
Page, Ann-Sophie [2 ,3 ]
De Coppi, Paolo [4 ,5 ,6 ]
Vergote, Simen [2 ,3 ]
Vercauteren, Tom [2 ,3 ,6 ]
Vander Poorten, Emmanuel [1 ]
Joyeux, Luc [2 ,3 ]
Deprest, Jan [2 ,3 ,4 ]
机构
[1] Dept Mech Engn, KU Leuven, Leuven, Belgium
[2] Univ Hosp Leuven, Dept Obstet & Gynecol, Leuven, Belgium
[3] Katholieke Univ Leuven, Dept Dev & Regenerat, Grp Biomed Sci, Cluster Woman & Child, Leuven, Belgium
[4] UCL, Inst Child & Womens Hlth, London, England
[5] Great Ormond St Hosp Sick Children, Natl Inst Hlth & Care Res, Biomed Res Ctr, Specialist Neonatal & Paediat Surg, London, England
[6] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
基金
英国惠康基金;
关键词
fetal surgery; fetoscopic surgery; fetoscopy; myelomeningcoele; spina bifida aperta; SIMULATION FIDELITY; TECHNICAL SKILL; REFERENCE RANGE;
D O I
10.1016/j.ajogmf.2024.101278
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: Fetoscopic spina bifida repair is increasingly being practiced, but limited skill acquisition poses a barrier to widespread adoption. Extensive training in relevant models, including both ex vivo and in vivo models may help. To address this, a synthetic training model that is affordable, realistic, and that allows skill analysis would be useful. OBJECTIVE: This study aimed to create a high-fidelity model for training in the essential neurosurgical steps of fetoscopic spina bifida repair using synthetic materials. In addition, we aimed to obtain a cheap and easily reproducible model. STUDY DESIGN: We developed a 3-layered, silicon-based model that resemble the anatomic layers of a typical myelomeningocele lesion. It allows for filling of the cyst with fluid and conducting a water tightness test after repair. A compliant silicon ball mimics the uterine cavity and is fixed to a solid 3-dimensional printed base. The fetal back with the lesion (single-use) is placed inside the uterine ball, which is reusable and repairable to allow for practicing port insertion and fixation multiple times. Following cannula insertion, the uterus is insuff lated and a clinical fetoscopic or robotic or prototype instruments can be used. Three skilled endoscopic surgeons each did 6 simulated fetoscopic repairs using the surgical steps of an open repair. The primary outcome was surgical success, which was determined by water tightness of the repair, operation time <180 minutes and an Objective Structured Assessment of Technical Skills score of >= 18of 25. Skill retention was measured using a competence cumulative sum analysis of a composite binary outcome of surgical success. Secondary outcomes were cost and fabrication time of the model. RESULTS: We made a model that can be used to simulate the neurosurgical steps of spina bifida repair, including anatomic details, port insertion, placode release and descent, undermining of skin and muscular layer, and endoscopic suturing. The model was made using reusable 3-dimensional printed molds and easily accessible materials. The 1-time startup cost was <euro>211, and each single-use, simulated myelomeningocele lesion cost <euro>9.5 in materials and 50 minutes of working time. Two skilled endoscopic surgeons performed 6 simulated, 3-port fetoscopic repairs, whereas a third used a Da Vinci surgical robot. Operation times decreased by more than 30% from the first to the last trial. Six experiments per surgeon did not show an obvious Objective Structured Assessment of Technical Skills score improvement. Competence cumulative sum analysis confirmed competency for each surgeon. CONCLUSION: This high-fidelity, low-cost spina bifida model allows simulated dissection and closure of a myelomeningocele lesion.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Validation of a high-fidelity training model for fetoscopic spina bifida surgery
    Luc Joyeux
    Allan Javaux
    Mary P. Eastwood
    Felix R. De Bie
    Gert Van den Bergh
    Rebecca S. Degliuomini
    Simen Vergote
    Talita Micheletti
    Geertje Callewaert
    Sebastien Ourselin
    Paolo De Coppi
    Frank Van Calenbergh
    Emmanuel Vander Poorten
    Jan Deprest
    Scientific Reports, 11
  • [2] Validation of a high-fidelity training model for fetoscopic spina bifida surgery
    Joyeux, Luc
    Javaux, Allan
    Eastwood, Mary P.
    De Bie, Felix R.
    Van den Bergh, Gert
    Degliuomini, Rebecca S.
    Vergote, Simen
    Micheletti, Talita
    Callewaert, Geertje
    Ourselin, Sebastien
    De Coppi, Paolo
    Van Calenbergh, Frank
    Vander Poorten, Emmanuel
    Deprest, Jan
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [3] HIGH-FIDELITY, LOW-COST PORCINE TRAINING MODEL FOR ARTERIAL LINE PLACEMENT
    Ting, Andrewston
    Jiang, Tianyu
    ANESTHESIA AND ANALGESIA, 2023, 136 : 45 - 47
  • [4] A low-cost high-fidelity model for abscess simulation
    Done, Aaron J.
    Fairres, Marshall J.
    Heiler, Joseph C.
    Smith, Cody J.
    Rappaport, William
    AMERICAN JOURNAL OF SURGERY, 2020, 219 (04): : 628 - 631
  • [5] Design and validation of a low-cost, high-fidelity model for robotic pyeloplasty simulation training
    Timberlake, Matthew D.
    Garbens, Alaina
    Schlomer, Bruce J.
    Kavoussi, Nicholas L.
    Kern, Adam J. M.
    Peters, Craig A.
    Gahan, Jeffery C.
    JOURNAL OF PEDIATRIC UROLOGY, 2020, 16 (03) : 332 - 339
  • [6] Development of a Low-cost, High-fidelity Skin Model for Suturing
    Williams, Taylor P.
    Snyder, Clifford L.
    Hancock, Kevin J.
    Iglesias, Nicholas J.
    Sommerhalder, Christian
    DeLao, Shannon C.
    Chacin, Aisen C.
    Perez, Alexander
    JOURNAL OF SURGICAL RESEARCH, 2020, 256 : 618 - 622
  • [7] Creating a high-fidelity, low-cost cricoid pressure training device
    Duke, N.
    Parson, M.
    ANAESTHESIA, 2016, 71 : 78 - 78
  • [8] Low-cost high-fidelity anaesthetic simulation
    Hartwell, D. A.
    Grayling, M.
    Kennedy, R. R.
    ANAESTHESIA AND INTENSIVE CARE, 2014, 42 (03) : 371 - 377
  • [9] Application of a Low-cost, High-fidelity Proximal Phalangeal Dislocation Reduction Model for Clinician Training
    Lord, Spencer
    Geary, Sean
    Lord, Garrett
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2023, 24 (05) : 839 - 846
  • [10] A versatile low-cost, high-fidelity cystoscopy simulation
    Igeh, A.
    Maldonado, P. A.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2022, 226 (03) : S1345 - S1345