APPROPRIATENESS AND QUALITY OF COMPOSITE ENDPOINT USE AND REPORTING IN SPINE SURGERY A Systematic Review

被引:0
|
作者
Pahuta, Markian [1 ]
Sarraj, Mohamed [1 ]
Muddaluru, Varun [2 ]
Gandhi, Pranjan [3 ]
Alshaalan, Fawaz [4 ]
Busse, Jason [5 ]
Guha, Daipayan [6 ]
Bhandari, Mohit [1 ]
机构
[1] McMaster Univ, Div Orthopaed, Fac Hlth Sci, Hamilton, ON, Canada
[2] Grad Entry Med Royal Coll Surg Ireland, Dublin, Ireland
[3] McMaster Univ, Med Sch, Hamilton, ON, Canada
[4] King Faisal Specialist Hosp & Res Ctr, Orthoped Surg Dept, Riyadh, Saudi Arabia
[5] McMaster Univ, Fac Hlth Sci, Dept Anesthesia & Hlth Evidence & Impact, Hamilton, ON, Canada
[6] McMaster Univ, Fac Hlth Sci, Div Neurosurg, Hamilton, ON, Canada
关键词
TOTAL DISC REPLACEMENT; INVESTIGATIONAL-DEVICE-EXEMPTION; INTERLAMINAR STABILIZATION; RANDOMIZED-TRIALS; ARTIFICIAL DISC; MULTICENTER; FUSION; OUTCOMES; DISKECTOMY; AUTOGRAFT;
D O I
10.2106/JBJS.RVW.24.00039
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: A composite endpoint (CEP) is a measure comprising 2 or more separate component outcomes. The use of these constructs is increasing. We sought to conduct a systematic review on the usage, quality of reporting, and appropriate use of CEPs in spine surgery research. Methods: A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Articles reporting randomized controlled trials of a spine surgery intervention using a CEP as a primary outcome were included. We assessed the quality of CEP reporting, appropriateness of CEP use, and correspondence between CEP treatment effect and component outcome treatment effect in the included trials. Results: Of 2,321 initial titles, 43 citations were included for analysis, which reported on 20 unique trials. All trials reported the CEP construct well. In 85% of trials, the CEP design was driven by US Food and Drug Administration guidance. In the majority of trials, the reporting of CEP results did not adhere to published recommendations: 43% of tests that reported statistically significant results on component outcomes were not statistically significant when adjusted for multiple testing. 67% of trials did not meet appropriateness criteria for CEP use. In addition, CEP treatment effect tended to be 6% higher than the median treatment effect for component outcomes. Conclusion: Given that CEP analysis was not appropriate for the majority of spine surgery trials and the inherent challenges in the reporting and interpretation of CEP analysis, CEP use should not be mandated by regulatory bodies in spine surgery trials.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Systematic review of the methodological and reporting quality of case series in surgery
    Agha, R. A.
    Fowler, A. J.
    Lee, S. -Y.
    Gundogan, B.
    Whitehurst, K.
    Sagoo, H. K.
    Jeong, K. J. L.
    Altman, D. G.
    Orgill, D. P.
    BRITISH JOURNAL OF SURGERY, 2016, 103 (10) : 1253 - 1258
  • [2] A systematic review of the methodological and reporting quality of case series in surgery
    Agha, R. A.
    Fowler, A. J.
    Lee, S.
    Gundogan, B.
    Whitehurst, K.
    Sagoo, H.
    Jeong, K.
    Altman, D. G.
    Orgill, D. P.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 32 - 33
  • [3] Complications Related to Osteobiologics Use in Spine Surgery A Systematic Review
    Mroz, Thomas E.
    Wang, Jeffrey C.
    Hashimoto, Robin
    Norvell, Daniel C.
    SPINE, 2010, 35 (09) : S86 - S104
  • [4] The reporting quality of systematic reviews in plastic surgery needs improvement: a systematic review
    Lee, S. Y.
    Sagoo, H. K.
    Whitehurst, K.
    Wellstead, G.
    Fowler, A. J.
    Agha, R.
    Orgill, D.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 50 - 50
  • [5] Assessing the quality of reporting on quality improvement initiatives in plastic surgery: A systematic review
    Pereira, D. Daniel
    Market, Marisa R.
    Bell, Stephanie A.
    Malic, Claudia C.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2023, 79 : 101 - 110
  • [6] Natural Language Processing in Spine Surgery: A Systematic Review of Applications, Bias, and Reporting Transparency
    Huang, Bonnie B.
    Huang, Jonathan
    Swong, Kevin N.
    WORLD NEUROSURGERY, 2022, 167 : 156 - +
  • [7] A Systematic Review of the Reporting Quality of Qualitative Research in Breast Plastic Surgery
    Hircock, Caroline
    Leveille, Cameron F.
    Chen, Jeffrey
    Lin, Xue-Wei
    Lansang, Rafael P.
    Kim, Patrick J.
    Huan, Peter W.
    Gallo, Lucas
    Thoma, Achilles
    PLASTIC SURGERY, 2025, 33 (01) : 44 - 50
  • [8] Randomised controlled trials in plastic surgery: A systematic review of reporting quality
    Agha R.A.
    Camm C.F.
    Doganay E.
    Edison E.
    Siddiqui M.R.S.
    Orgill D.P.
    European Journal of Plastic Surgery, 2014, 37 (2) : 55 - 62
  • [9] Preoperative Opioid Use and Clinical Outcomes in Spine Surgery: A Systematic Review
    Yerneni, Ketan
    Nichols, Noah
    Abecassis, Zachary A.
    Karras, Constantine L.
    Tan, Lee A.
    NEUROSURGERY, 2020, 86 (06) : E490 - E507
  • [10] Exoscope Use in Spine Surgery: A Systematic Review of Applications, Benefits, and Limitations
    Vattipally, Vikas N.
    Jiang, Kelly
    Weber-Levine, Carly
    Rosin, Richard
    Davidar, A. Daniel
    Hersh, Andrew M.
    Khalifeh, Jawad
    Ahmed, A. Karim
    Azad, Tej D.
    Ashayeri, Kimberly
    Lubelski, Daniel
    Mukherjee, Debraj
    Huang, Judy
    Theodore, Nicholas
    WORLD NEUROSURGERY, 2024, 184