Neutron spectroscopy for Boron Neutron Capture Therapy beams characterization

被引:0
|
作者
Monti, V. [1 ,2 ]
Costa, M. [1 ,2 ]
Durisi, E. [1 ,2 ]
Mafucci, E. [1 ,2 ]
Calamida, A.
Campoy, A. I. Castro [3 ]
Fontanilla, A. [3 ]
Russo, L. [3 ]
Bedogni, R. [3 ]
机构
[1] Univ Torino, Via Pietro Giuria 1, I-10125 Turin, Italy
[2] INFN, Sez Torino, Via Pietro Giuria 1, I-10125 Turin, Italy
[3] INFN, Lab Nazl Frascati, Via Enrico Fermi 40, I-00044 Frascati, Italy
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 05期
关键词
Detector design and construction technologies and materials; Instrumentation for hadron therapy; NCT-WES; SPECTROMETER;
D O I
10.1088/1748-0221/19/05/C05036
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Boron Neutron Capture Therapy (BNCT) is a therapeutic treatment for malignant tumors that utilizes the nuclear reactions that happen when thermal neutrons are captured by boron-10 atoms to selectively destroy designated cells. Boron-10 atoms are biochemically accumulated inside the tumor target, which is then irradiated with thermal neutrons. In recent years, the possibility to obtain accelerator based intense neutron beams has given a boost to the diffusion of BNCT also in Europe, removing the need of nuclear reactors. In this contest, the monitoring and characterization of the epithermal neutron beams dedicated to BNCT becomes an important issue. The directional neutron spectrometer called NCT-WES (Neutron Capture Therapy Wide Energy Spectrometer) is a single moderator neutron spectrometer composed of a polyethylene cylinder embedding six semiconductor- based detectors positioned at different depths along the cylinder axes. The position of the six detectors is studied in order to maximize the response of each one in a selected neutron energy range. The unfolding of the six simultaneous readings allows to reconstruct the incoming neutron energy spectrum as in a parallelized Bonner Sphere System. A cylindrical collimator situated in the front of the spectrometer makes the instrument sensitive to neutrons coming only from a given direction, which allows to exclude the contribution of the room scattered radiation. The experimental validation of the spectrometer, obtained through several measuring campaigns, is reported and discussed.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fast Neutron Beams for Boron Neutron Capture Therapy?
    Wolber, Gerd
    Zeitschrift fur Medizinische Physik, 2004, 14 (01): : 55 - 63
  • [2] Characterization of neutron beams for boron neutron capture therapy: In-air radiobiological dosimetry
    Yamamoto, T
    Matsumura, A
    Yamamoto, K
    Kumada, H
    Hori, N
    Torii, Y
    Shibata, Y
    Nose, T
    RADIATION RESEARCH, 2003, 160 (01) : 70 - 76
  • [4] Design of neutron beams for boron neutron capture therapy for TRIGA reactor
    Musashi Inst of Technology, Kawasaki, Japan
    J Nucl Sci Technol, 2 (171-178):
  • [5] New data for the definition of neutron beams for Boron Neutron capture therapy
    Macias, M.
    Fernandez, B.
    Praena, J.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 185
  • [6] Optimized accelerator based epithermal neutron beams for boron neutron capture therapy
    Kudchadker, RJ
    MEDICAL PHYSICS, 1997, 24 (07) : 1182 - 1182
  • [7] Epithermal neutron beams for clinical studies of boron neutron capture therapy: A dosimetric comparison of seven beams
    Binns, PJ
    Riley, KJ
    Harling, OK
    RADIATION RESEARCH, 2005, 164 (02) : 212 - 220
  • [8] Designing accelerator-based epithermal neutron beams for boron neutron capture therapy
    Bleuel, DL
    Donahue, RJ
    Ludewigt, BA
    Vujic, J
    MEDICAL PHYSICS, 1998, 25 (09) : 1725 - 1734
  • [9] Neutron capture autoradiography for a study on boron neutron capture therapy
    Ogura, K
    Yamazaki, A
    Yanagie, H
    Eriguchi, M
    Lehmann, EH
    Küehne, G
    Bayon, G
    Maruyama, K
    Kobayashi, H
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 555 - 558
  • [10] Boron neutron capture therapy
    Kato, I
    ORAL ONCOLOGY, 2005, 1 (01) : 63 - 63