Performance experiments and pressure drop prediction modelling of an energy-saving cyclone separator

被引:1
|
作者
Si, Daorun [1 ]
Yan, Zihan [1 ]
Lu, Chunxi [1 ]
机构
[1] China Univ Petr, Sch Chem Engn & Environm, State Key Lab Heavy Oil Proc, Beijing 102249, Peoples R China
关键词
Axial inlet cyclone separator; Guide vane; Separation efficiency; Pressure drop; EFFICIENCY; SCALE; GAS;
D O I
10.1016/j.fuel.2024.132165
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The study proposes a new type of axial-inlet cyclone separator with the smaller cylinder-cone ratio and an expansion tube at the particle exhaust, named energy-saving cyclone separator, which offers several advantages over the traditional tangential inlet cyclone in engineering units. Experimental results demonstrate that the separation efficiency exceeds 83 % for fine particles smaller than 10 mu m, while the pressure drop is significantly lower than that of the commonly used PV-type tangential inlet cyclone separator, at only 44 % of the PV cyclone separator's pressure drop. Moreover, the flow fields of energy-saving cyclone separator are measured to analyze its characteristics. It is found that the lower tangential momentum ratio in both the inner and outer swirl zones of energy-saving cyclone separator reduces the dissipation of dynamic swirl pressure at the bottom of the cone section and outlet pipe, resulting in a lower pressure drop. The high proportion of downward axial momentum in the outer swirl section causes the separated large particles to discharge through the dust exhaust, improving the separation efficiency of coarse particles. Furthermore, a model to predict the pressure drop of energy-saving cyclone separator is developed.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Pressure drop in cyclone separator at high pressure
    Zhu Zhiping
    Na Yongjie
    Lu Qinggang
    JOURNAL OF THERMAL SCIENCE, 2008, 17 (03) : 275 - 280
  • [2] Pressure Drop in Cyclone Separator at High Pressure
    Zhu Zhiping~(1
    Journal of Thermal Science, 2008, 17 (03) : 275 - 280
  • [3] Pressure drop in cyclone separator at high pressure
    Zhiping Zhu
    Yongjie Na
    Qinggang Lu
    Journal of Thermal Science, 2008, 17 : 275 - 280
  • [4] CFD study on the performance of reducing pressure drop holes in cyclone separator
    Prasanna, N.
    Subramanian, Karthikeyan
    Ajay, S.
    Rajagopal, T.
    Vigneshwaran, V.
    MATERIALS TODAY-PROCEEDINGS, 2021, 43 : 1960 - 1968
  • [5] Empirical formulas and CFD prediction of a cyclone type oil separator pressure drop
    Li, Xinfeng
    Hayase, Gaku
    Lee, Jaikwon
    Youn, Baek
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 49 - +
  • [6] Effects of Geometrical Parameters on the Pressure Drop for a Modified Cyclone Separator
    Tan, Fuat
    Karagoz, Irfan
    Avci, Atakan
    CHEMICAL ENGINEERING & TECHNOLOGY, 2016, 39 (03) : 576 - 581
  • [7] Control and Experiments with Energy-Saving SCARA Robots
    Iwamura, Makoto
    Schiehlen, Werner
    ROMANSY 21 - ROBOT DESIGN, DYNAMICS AND CONTROL, 2016, 569 : 153 - 161
  • [8] Effect of a reducing pressure drop stick in the flow field of a cyclone separator
    Liu, Chengwen
    Wang, Lianze
    Wang, Jianjun
    Liu, Qiusheng
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2007, 47 (02): : 293 - 296
  • [9] Design of vortex finder structure for decreasing the pressure drop of a cyclone separator
    Sun, Yaquan
    Yu, Junzhi
    Wang, Weibing
    Yang, Shanglin
    Hu, Xue
    Feng, Jingan
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2020, 37 (05) : 743 - 754
  • [10] Design of vortex finder structure for decreasing the pressure drop of a cyclone separator
    Yaquan Sun
    Junzhi Yu
    Weibing Wang
    Shanglin Yang
    Xue Hu
    Jingan Feng
    Korean Journal of Chemical Engineering, 2020, 37 : 743 - 754