Wind-induced interference effect of complex building clusters on long-span roof structures

被引:2
|
作者
Wu, Yanru [1 ]
Zhang, Wen [1 ]
Miao, Pengyong [1 ]
Liu, Yan [1 ]
Xing, Guohua [1 ]
机构
[1] Changan Univ, Dept Civil Engn, Xian 710061, Peoples R China
基金
中国国家自然科学基金;
关键词
Long -span roof structure; Wind tunnel test; Interference effect; Non-gaussian features; Peak factor; Peak pressure coefficient; PRISMATIC BUILDINGS; PRESSURE; LOADS; FLOW;
D O I
10.1016/j.jfluidstructs.2024.104157
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The presence of complex buildings introduces interference effects and complicates the wind field around the long-span roof structure. The complexity of the problem makes it challenging to predict wind load of long-span roof structures, resulting in a scarcity of design data available to engineers and designers. Thus, the influence of interference effect on mean and peak pressure coefficients of a long-span tri-centered cylindrical roof structure was investigated through wind tunnel tests conducted in an atmospheric boundary layer wind tunnel. The study focused on the interference effects caused by two cooling towers, chimney, and some low-rise buildings, considering all wind directions. The results show that the interference effects are the result of a combination of amplification effects from the adjacent cooling towers and chimney and shielding effects from the surrounding low-rise buildings. Due to the shielding effect of low-rise buildings, the wind suction on the roof is mitigated compared to that of a single building, while at the end of the roof, wind suction is amplified by cooling tower effects. The interference effect of the building clusters, however, amplifies the fluctuating wind pressure coefficient and the peak pressure coefficient on the roof. To accurately estimate the wind load of building components and envelopes, furthermore, this study investigates the influence mechanism of interference effect on nonGaussian characteristics of wind pressure combining with fluctuating wind pressure spectrum, spatial correlation of fluctuating wind pressure, and probability distribution characteristics of standardized wind pressure coefficient. The spatial correlation of wind pressure in the roof interference area exhibits a strong association, and the probability density distribution characteristics of the standardized wind pressure coefficient significantly deviate from the Gaussian curve, with a peak factor exceeding 3.5. Thus, it can be concluded that the wind pressure within this region demonstrates significant non-Gaussian characteristics. Hence, the zone values of peak pressure coefficients are determined using the peak factor approach to inform the wind resistance design of the envelope structure.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Wind-induced interference effect of complex building clusters on long-span roof structures
    Wu, Yanru
    Zhang, Wen
    Miao, Pengyong
    Liu, Yan
    Xing, Guohua
    Journal of Fluids and Structures, 129
  • [2] Wind-induced dynamic response and wind load factor for long-span flat roof structures
    Lu, Feng
    Lou, Wen-Juan
    Sun, Bing-Nan
    Gongcheng Lixue/Engineering Mechanics, 2002, 19 (02): : 52 - 57
  • [3] Wind-induced vibration of the roof system of a long-span light-weighted steel structures
    Ma, Jun
    Zhou, Dai
    Dong, Shi-Ling
    Zhu, Zhong-Yi
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 631 - 638
  • [4] Study on the Wind-induced Interference Effect of a Large-span Roof Structure Building Group
    Yong Hao
    Tian-jiao Han
    Hang-fei Wu
    Hua-hai Dong
    Yin Zhou
    Chun-hui Du
    Yun-hui Han
    KSCE Journal of Civil Engineering, 2024, 28 : 1392 - 1410
  • [5] Study on the Wind-induced Interference Effect of a Large-span Roof Structure Building Group
    Hao, Yong
    Han, Tian-jiao
    Wu, Hang-fei
    Dong, Hua-hai
    Zhou, Yin
    Du, Chun-hui
    Han, Yun-hui
    KSCE JOURNAL OF CIVIL ENGINEERING, 2024, 28 (04) : 1392 - 1410
  • [6] Reliability assessment of a building complex with four long-span roof structures based on wind tunnel experiments
    Huang, Mingfeng
    Tang, Gui
    Ni, Yi-Qing
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2021, 11 (05) : 1461 - 1475
  • [7] Reliability assessment of a building complex with four long-span roof structures based on wind tunnel experiments
    Mingfeng Huang
    Gui Tang
    Yi-Qing Ni
    Journal of Civil Structural Health Monitoring, 2021, 11 : 1461 - 1475
  • [8] Wind-induced dynamic response and resultant load estimation for a flat long-span roof
    Uematsu, Y
    Yamada, M
    Sasaki, A
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 65 (1-3) : 155 - 166
  • [9] New method for calculating wind-induced vibration of long-span cable roof structure
    Mao J.
    Nie Z.
    Wang D.
    Xu W.
    Ou T.
    Chen W.
    Wu F.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (05): : 101 - 112
  • [10] Research on the interference effect of surrounding buildings on the wind load of long-span roof
    Li, Bo
    Yang, Qing-Shan
    Feng, Shao-Hua
    Fan, Zhong
    Shiyan Liuti Lixue/Journal of Experiments in Fluid Mechanics, 2012, 26 (05): : 27 - 30