Recommended operating conditions and performance evaluation of commonly used hydrofluoroolefin (HFO) and hydrochlorofluoroolefin (HCFO) refrigerants in organic Rankine cycle

被引:1
|
作者
Zhang, Xinxin [1 ,2 ]
Li, Yingzhen [1 ,2 ]
机构
[1] Beijing Univ Technol, Key Lab Enhanced Heat Transfer & Energy Conservat, MOE, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Heat Transfer & Energy Convers, Beijing 100124, Peoples R China
关键词
HFO; HCFO; Molecular complexity; Characteristic points; Characteristic regions; Organic rankine cycle; WORKING FLUIDS; HEAT-RECOVERY; GWP;
D O I
10.1016/j.energy.2024.131488
中图分类号
O414.1 [热力学];
学科分类号
摘要
The application of the first three generations of organic refrigerants, namely, CFCs, HCFCs, and HFCs, in an organic Rankine cycle has been widely investigated. As environmentally friendly successors to the above three generations of refrigerants, hydrofluoroolefins (HFOs) and hydrochlorofluoroolefins (HCFOs) have also attracted increasing research interest for their application in the organic Rankine cycle (ORC). Based on molecular complexity, characteristic points on saturation liquid and vapor curve and area of characteristic regions in temperature-entropy (T-s) diagram, eight common hydrofluoroolefins (HFOs) and hydrochlorofluoroolefins (HCFOs) are classified, analyzed, and evaluated. In addition, the type of heat source and specific operating conditions in which these eight hydrofluoroolefins (HFOs) and hydrochlorofluoroolefins (HCFOs) are most effective are recommended. The results show that molecular complexity of hydrofluoroolefins (HFOs) and hydrochlorofluoroolefins (HCFOs) mainly depends on the length of the C chain, and then on the number and location of Cl and F atoms. HFO-1243zf has the best comprehensive evaluation indicator, and it is noteworthy as a recommended working fluid for subcritical ORC systems. The result obtained in this paper may provide a reference for the design and actual operation of Organic Rankine Cycle system using HFO and HCFO as working fluids.
引用
收藏
页数:9
相关论文
共 11 条
  • [1] PERFORMANCE EVALUATION OF A TURBINE USED IN A REGENERATIVE ORGANIC RANKINE CYCLE
    Li, Maoqing
    Wang, Jiangfeng
    Gao, Lin
    Niu, Xiaoqiang
    Dai, Yiping
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 6, 2012, : 425 - 432
  • [2] Performance evaluation of free piston compressor coupling organic Rankine cycle under different operating conditions
    Han, Yongqiang
    Kang, Jianjian
    Zhang, Guangpan
    Liu, Zhongchang
    Tian, Jing
    Chai, Jiahong
    ENERGY CONVERSION AND MANAGEMENT, 2014, 86 : 340 - 348
  • [3] Effects of variable operating conditions of working fluid pumps on the performance of organic Rankine cycle system
    Yang, Yuxin
    Zhang, Hongguang
    Zhao, Rui
    Li, Jian
    Zhao, Tenglong
    Zhang, Mengru
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (02): : 851 - 857
  • [4] Performance Evaluation of a Solar-Powered Regenerative Organic Rankine Cycle in Different Climate Conditions
    Spayde, Emily
    Mago, Pedro J.
    Cho, Heejin
    ENERGIES, 2017, 10 (01)
  • [5] Study on the Performance of the Organic Rankine Cycle System with Internal Heat Exchanger under Vehicle Engine Various Operating Conditions
    Yang, Kai
    Zhang, Hongguang
    Wang, Zhen
    Zhang, Jian
    Yang, Fubin
    Wang, Enhua
    Yao, Baofeng
    MATERIAL SCIENCE AND ENGINEERING TECHNOLOGY II, 2014, 856 : 349 - +
  • [6] Performance Analysis of a Multistage Centrifugal Pump Used in an Organic Rankine Cycle(ORC) System under Various Condensation Conditions
    YANG Yuxin
    ZHANG Hongguang
    TIAN Guohong
    XU Yonghong
    WANG Chongyao
    GAO Jianbing
    Journal of Thermal Science, 2019, 28 (04) : 621 - 634
  • [7] Performance Analysis of a Multistage Centrifugal Pump Used in an Organic Rankine Cycle (ORC) System under Various Condensation Conditions
    Yang, Yuxin
    Zhang, Hongguang
    Tian, Guohong
    Xu, Yonghong
    Wang, Chongyao
    Gao, Jianbing
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (04) : 621 - 634
  • [8] Performance Analysis of a Multistage Centrifugal Pump Used in an Organic Rankine Cycle (ORC) System under Various Condensation Conditions
    Yuxin Yang
    Hongguang Zhang
    Guohong Tian
    Yonghong Xu
    Chongyao Wang
    Jianbing Gao
    Journal of Thermal Science, 2019, 28 : 621 - 634
  • [9] Performance Evaluation of a Helical Coil Heat Exchanger Working under Supercritical Conditions in a Solar Organic Rankine Cycle Installation
    Lazova, Marija
    Huisseune, Henk
    Kaya, Alihan
    Lecompte, Steven
    Kosmadakis, George
    De Paepe, Michel
    ENERGIES, 2016, 9 (06)
  • [10] Performance analysis of waste heat recovery with a dual loop organic Rankine cycle (ORC) system for diesel engine under various operating conditions
    Yang, Fubin
    Dong, Xiaorui
    Zhang, Hongguang
    Wang, Zhen
    Yang, Kai
    Zhang, Jian
    Wang, Enhua
    Liu, Hao
    Zhao, Guangyao
    ENERGY CONVERSION AND MANAGEMENT, 2014, 80 : 243 - 255