Grid-connected PV system in air cooled double-stage ORC geothermal power plant performance evaluation, case study: Sultanhisar GPP-2

被引:0
|
作者
Kacmaz, Seyma [1 ]
Demirpolat, Havva [2 ]
机构
[1] Celikler Holding, Ankara, Turkiye
[2] Selcuk Univ, Fac Technol, Dept Mech Engn, Konya, Turkiye
关键词
grid-connected PV system; ORC; Sultanhisar GPP-2; ORGANIC RANKINE-CYCLE; WORKING FLUID; WASTE HEAT; RENEWABLE ENERGY; DESIGN; CONFIGURATIONS; GENERATION; CRITERIA; REGION; TURKEY;
D O I
10.1002/ep.14460
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Many factors determine the percentage of parasitic load of the geothermal power plant. Domestic consumption accounts for about 20-25 per cent of total production in low-temperature geothermal power plants. As a case study, the ratio of a 1 MW grid-connected PV system to the internal consumption of the Sultanhisar GPP-2 and its effect on increasing the efficiency of the system have been examined. The current production of the power plant has been modeled thermodynamically with the parameters taken from the plant, and the efficiency of the system has been calculated. Sultanhisar GPP-2, which operates at a geothermal well temperature of 140.2 degrees C and a net efficiency of 6.28%, has a domestic consumption to production ratio of around 25%. The installation of a 1 MW PV system is expected to produce 2140MWh per year, equivalent to 7% of the internal energy consumption.
引用
收藏
页数:11
相关论文
共 19 条
  • [1] Comparison Study of MPPT Control Strategies for Double-stage PV Grid-connected Inverter
    Wang, Yubin
    Yu, Xichang
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 1561 - 1565
  • [2] Evaluation of a grid-connected PV power plant: performance and agrivoltaic aspects
    Saka, Kenan
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2024, 26 (12) : 32319 - 32336
  • [3] Single-phase Double-stage PV Grid-connected System Based on Multi-carrier PWM
    Zhou, Guoshun
    Lin, Yejin
    Liu, Yancheng
    Zhang, Qinjin
    AUTOMATIC MANUFACTURING SYSTEMS II, PTS 1 AND 2, 2012, 542-543 : 1231 - +
  • [4] Comparative Power Quality Performance Evaluation of Grid-Connected Solar PV System
    Kumar P.
    Ranjan R.
    Yadav A.K.
    Journal of The Institution of Engineers (India): Series B, 2024, 105 (03) : 585 - 594
  • [5] Feasibility study and Performance evaluation of a grid-connected Rooftop Solar PV system
    Vasita, Jaya
    Shakhiya, Querie
    Modi, Jvalant
    2017 IEEE INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION, INSTRUMENTATION AND CONTROL (ICICIC), 2017,
  • [6] Enhancing Performance and Power Quality of a Double-Stage Grid-Connected PV Systems Using Advanced Control Techniques and A Dual-Extended Kalman Filter
    Brahimi, Aboubakr
    Kerdoun, Djallel
    Boumassata, Abderraouf
    Dahmani, Kaouthar Lalia
    PRZEGLAD ELEKTROTECHNICZNY, 2024, 100 (09): : 44 - 50
  • [7] A Mathematical Model and Performance Evaluation for a Single-Stage Grid-Connected Photovoltaic (PV) System
    Dash, Prajna Paramita
    Yazdani, Amirnaser
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2008, 9 (06):
  • [8] Dispatched Power and Unbalanced Operation of a Three-Phase NPC Based Double-Stage Grid Connected PV System
    Rahman, Md Mizanur
    Hossain, Shafayet
    Rezwan, Sifat
    2019 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL INFORMATION AND COMMUNICATION TECHNOLOGY (EICT), 2019,
  • [9] Performance Evaluation of Burkina Faso's 33 MW Largest Grid-Connected PV Power Plant
    Palm, Sami Florent
    Youssef, Lamkharbach
    Waita, Sebastian
    Nyangonda, Thomas Nyachoti
    Radouane, Khalid
    Chebak, Ahmed
    ENERGIES, 2023, 16 (17)
  • [10] Improving the performance of an existing air-cooled binary geothermal power plant: A case study
    Kanoglu, M
    Cengel, YA
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1999, 121 (03): : 196 - 202