Head-to-head comparison of four plasma neurofilament light chain (NfL) immunoassays

被引:4
|
作者
Ashrafzadeh-Kian, Susan [1 ]
Figdore, Daniel [1 ]
Larson, Bethany [1 ]
Deters, Rebecca [1 ]
Abou-Diwan, Charbel [2 ]
Bornhorst, Joshua [1 ]
Algeciras-Schimnich, Alicia [1 ]
机构
[1] Mayo Clin, Dept Lab Med & Pathol, Rochester, MN 55906 USA
[2] Siemens Healthcare Diagnost Inc, Tarrytown, NY USA
关键词
Neurofilament light chain; Blood NfL; Amyotrophic lateral sclerosis; Multiple sclerosis;
D O I
10.1016/j.cca.2024.119817
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Neurofilament Light Chain (NfL) is an emerging blood biomarker of neuro-axonal injury and neurodegeneration with the potential to be used in the clinical management of various neurological conditions. Various NfL immunoassays are in development on high-throughput automated systems, but little information is available related to the comparability between assays. In this study, we performed a head-to-head comparison of four NfL immunoassays using plasma samples from individuals with various neurological conditions. Methods: EDTA plasma samples in which NfL was ordered clinically were stratified according to diagnosis. NfL concentrations (pg/mL) in plasma were obtained using the Quanterix Simoa (R), the Roche Elecsys, the Siemens Healthineers Atellica (R) IM, and the Fujirebio Lumipulse (R) NfL assays. Passing-Bablok regression analyses were performed to assess the correlation and bias between methods. Additionally, the distribution of NfL concentrations for each assay was assessed in three disease groups: amyotrophic lateral sclerosis (ALS) upon initial diagnosis, ALS treated, and multiple sclerosis (MS). Results: The R-2 between assays were all >= 0.95, however, significant proportional bias was observed between some assays. In particular, the Roche Elecsys assay NfL concentrations were significantly lower (similar to 85 %) when compared against the other three assays. The four assays were comparable with regards to the percentage of patients that were identified as having an elevated NfL result in the various clinical groups: ALS initial diagnoses (83-94 %), ALS untreated (93-100 %), and MS (8-18 %). Conclusions: This is the first study describing a head-to-head comparison of four automated NfL immunoassays. We demonstrate that there is a strong correlation between assays but a lack of standardization which is evident by the bias observed between some of the evaluated methods. These analytical differences will be important to consider when using NfL as a biomarker of neurodegeneration.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Head-to-head comparison of four cerebrospinal fluid and three plasma neurofilament light chain assays in Parkinsonism
    Simone Baiardi
    Marcello Rossi
    Giulia Giannini
    Angela Mammana
    Barbara Polischi
    Luisa Sambati
    Andrea Mastrangelo
    Franco Magliocchetti
    Pietro Cortelli
    Sabina Capellari
    Giovanna Calandra Buonaura
    Piero Parchi
    npj Parkinson's Disease, 11 (1)
  • [2] Comparison of four plasma neurofilament light chain (NfL) immunoassays in various neurological conditions
    Algeciras-Schimnich, A.
    Ashrafzadeh-Kian, S.
    Figdore, D.
    Larson, B.
    Deters, R.
    Abou-Diwan, C.
    Bornhorst, J.
    CLINICA CHIMICA ACTA, 2024, 558 : 67 - 67
  • [3] Plasma and CSF biomarkers in a memory clinic: Head-to-head comparison of phosphorylated tau immunoassays
    Ashton, Nicholas J.
    Puig-Pijoan, Albert
    Mila-Aloma, Marta
    Fernandez-Lebrero, Aida
    Garcia-Escobar, Greta
    Gonzalez-Ortiz, Fernando
    Kac, Przemyslaw R.
    Brum, Wagner S.
    Benedet, Andrea L.
    Lantero-Rodriguez, Juan
    Day, Theresa A.
    Vanbrabant, Jeroen
    Stoops, Erik
    Vanmechelen, Eugeen
    Triana-Baltzer, Gallen
    Moughadam, Setareh
    Kolb, Hartmuth
    Ortiz-Romero, Paula
    Karikari, Thomas K.
    Minguillon, Carolina
    Sanchez, Juan Jose Hernandez
    Navalpotro-Gomez, Irene
    Grau-Rivera, Oriol
    Manero, Rosa Maria
    Puente-Periz, Victor
    de la Torre, Rafael
    Roquer, Jaume
    Dage, Jeff L.
    Zetterberg, Henrik
    Blennow, Kaj
    Suarez-Calvet, Marc
    ALZHEIMERS & DEMENTIA, 2023, 19 (05) : 1913 - 1924
  • [4] A head-to-head comparison of four grading systems for oral epithelial dysplasia
    Hankinson, Paul
    Clark, Mollie
    Walsh, Hannah
    Khurram, Syed Ali
    HISTOPATHOLOGY, 2024,
  • [5] Reference values for plasma neurofilament light chain (NfL) in healthy Chinese
    Chen, Jingshan
    Yang, Xiaoxia
    Zhang, Ying
    Zheng, Pei
    Wei, Changjuan
    Mao, Zhifeng
    He, Wenyan
    Jin, Wei-Na
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (04) : E153 - E156
  • [6] Performance characteristics of five immunoassays for SARS-CoV-2: a head-to-head benchmark comparison
    Stoesser, Nicole
    LANCET INFECTIOUS DISEASES, 2020, 20 (12): : 1390 - 1400
  • [7] Acceptability of oral iodinated contrast media: a head-to-head comparison of four media
    Pollentine, A.
    Ngan-Soo, E.
    McCoubrie, P.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1025):
  • [8] A head-to-head comparison of four systems for oral epithelial dysplasia grading and prognostication
    Hankinson, P.
    Clark, M.
    Walsh, H.
    Khurram, A.
    VIRCHOWS ARCHIV, 2024, 485 : S124 - S124
  • [9] HEAD-TO-HEAD COMPARISON OF RISEDRONATE AND ALENDRONATE
    Christiansen, C.
    Phipps, R.
    Burgio, D.
    Sun, L.
    Russell, D.
    Keck, B.
    Kuzmak, B.
    Lindsay, R.
    CALCIFIED TISSUE INTERNATIONAL, 2004, 74 : S36 - S37
  • [10] Tirzepatide and Semaglutide in a Head-to-Head Comparison
    Krome, Susanne
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2025, 63 (02):