Assessment of window renovation potential in an apartment with an energy performance approach

被引:1
|
作者
Pekdogan, Tugce [1 ]
Yildizhan, Hasan [2 ,3 ]
Ahmadi, Mohammad Hossein [4 ]
Sharifpur, Mohsen [5 ,6 ]
机构
[1] Adana Alparslan Turkes Sci & Technol Univ, Dept Architecture, TR-01250 Adana, Turkiye
[2] Adana Alparslan Turkes Sci & Technol Univ, Dept Energy Syst Engn, TR-01250 Adana, Turkiye
[3] Imperial Coll London, Dept Chem Engn, Clean Energy Proc CEP Lab, London SW7 2AZ, England
[4] Shahrood Univ Technol, Fac Mech Engn, Shahrood 3619995161, Iran
[5] Univ Witwatersrand, Sch Mech Ind & Aeronaut Engn, Private Bag 3, ZA-2050 Johannesburg, South Africa
[6] China Med Univ, China Med Univ Hosp, Dept Med Res, Taichung, Taiwan
关键词
redesign; simulation-based design; energy use; window-to-wall ratio; residential building; OFFICE BUILDINGS; OPTIMIZATION; PLANT;
D O I
10.1093/ijlct/ctae066
中图分类号
O414.1 [热力学];
学科分类号
摘要
Windows are of great importance in improving the energy efficiency of buildings. It is possible to achieve this with the help of the regeneration of window design. The amount of energy used, the expense of heating and cooling, and the emissions of greenhouse gases that contribute to climate change can all be significantly reduced by improving the energy efficiency of windows. For this, computer modeling and BIM-based simulation programs provide significant timesaving in simultaneously evaluating design variations' visual and thermal results. This study selected a four-story residential building to analyze the energy load and thermal comfort of the windows redesign and examine the energy-saving potential for residential buildings. To analyze the renewed window design strategies, a four-story apartment building is selected as a case study in Izmir/Turkey (38 degrees 4 ', 27 degrees 2 '). This apartment is built on a 90 m2 gross floor area. The existing indoor environmental conditions of the flat are generally observed as cool and low illuminated by the occupants, so the window design options must be compared and renewed. As the first option, current conditions are simulated. The second option is to simulate different patterns for window-to-wall ratio (WWR). Moreover, the third option is to simulate different types of glass in each window. Currently, the WWR of the selected flat in the north, east and south directions is around 10%. But more is needed to provide daylight to the apartment. This article used Autodesk Revit and Green Building Studio simulations to investigate WWR and glass types and evaluate energy use intensity's (EUI) impact. As a result, this study shows that a 10% WWR on all building facades leads to an EUI of 993.9 MJ/m2/year. In contrast, increasing the WWR to 95% significantly increased EUI, reaching 2121 MJ/m2/year. In addition, it has been shown that the use of low U-value glasses, such as translucent wall panels and super-insulated three-pane clear Low-E, can provide energy savings of up to 5% per year, and especially the super-insulated three-pane Low-E glass type provides the highest efficiency on all facades.
引用
收藏
页码:1529 / 1539
页数:11
相关论文
共 50 条
  • [1] Development and Performance Assessment of Prefabricated Insulation Elements for Deep Energy Renovation of Apartment Buildings
    Pihelo, Peep
    Kuusk, Kalle
    Kalamees, Targo
    ENERGIES, 2020, 13 (07)
  • [2] Towards a BIM Approach for a High Performance Renovation of Apartment Buildings
    Aldanondo, M.
    Barco-Santa, A.
    Vareilles, E.
    Falcon, M.
    Gaborit, P.
    Zhang, L.
    PRODUCT LIFECYCLE MANAGEMENT FOR A GLOBAL MARKET (PLM 2014), 2014, 442 : 21 - 30
  • [3] Configuration of High Performance Apartment Buildings Renovation: A Constraint Based Approach
    Vareilles, E.
    Barco Santa, A. F.
    Falcon, M.
    Aldanondo, M.
    Gaborit, P.
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT (IEEM 2013), 2013, : 684 - 688
  • [4] Energy renovation of apartment buildings damaged in earthquakes
    Bogdan, Andela
    GRADEVINAR, 2023, 75 (06): : 616 - 617
  • [5] Cost-effectiveness of energy performance renovation measures in Finnish brick apartment buildings
    Niemela, Tuomo
    Kosonen, Risto
    Jokisalo, Juha
    ENERGY AND BUILDINGS, 2017, 137 : 60 - 75
  • [6] Nearly zero energy renovation concepts for apartment buildings
    Kuusk, Kalle
    Naumann, Jens
    Gritzki, Annina
    Felsmann, Clemens
    De Carli, Michele
    Tonon, Massimo
    Kurnitski, Jarek
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [7] Energy performance assessment of an electrochromic window
    Papaefthimiou, S
    Syrrakou, E
    Yianoulis, P
    THIN SOLID FILMS, 2006, 502 (1-2) : 257 - 264
  • [8] INCREASED ALLOCATION FOR ENERGY RENOVATION OF MULTI-APARTMENT BUILDINGS
    不详
    GRADEVINAR, 2023, 75 (01): : 112 - 112
  • [9] Effect of apartment building energy renovation on hourly power demand
    Hirvonen, Janne
    Jokisalo, Juha
    Heljo, Juhani
    Kosonen, Risto
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2019, 38 (10) : 918 - 936
  • [10] A dynamic energy performance-driven approach for assessment of buildings energy Renovation-Danish case studies
    Jradi, M.
    Veje, C. T.
    Jorgensen, B. N.
    ENERGY AND BUILDINGS, 2018, 158 : 62 - 76