Voltammetric sensor based on a Ni-Co-layered double hydroxide/ multi-walled carbon nanotubes nanocomposite for 4-aminophenol determination

被引:3
|
作者
Tajik, Somayeh [1 ]
Beitollahi, Hadi [2 ]
Mohammadi, Sayed Zia [3 ]
Nejad, Fariba Garkani [2 ]
Dourandish, Zahra [2 ]
机构
[1] Kerman Univ Med Sci, Res Ctr Trop & Infect Dis, Kerman, Iran
[2] Grad Univ Adv Technol, Environm Dept, Inst Sci & High Technol & Environm Sci, Kerman, Iran
[3] Payame Noor Univ, Dept Chem, Tehran, Iran
来源
CHEMICAL PHYSICS IMPACT | 2024年 / 8卷
关键词
4-Aminophenol; Modified electrode; Ni-Co-LDH/MWCNTs nanocomposite; Voltammetry; ELECTROCHEMICAL SENSOR; P-AMINOPHENOL; ELECTRODE; SURFACE; PARACETAMOL;
D O I
10.1016/j.chphi.2024.100653
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work, we developed a simple technique to produce an effective electrode material consisting of nickelcobalt-layered double hydroxide/multi-walled carbon nanotubes nanocomposite (Ni-Co-LDH/MWCNTs). This nanocomposite was prepared and characterization techniques such as field -emission scanning electron microscopy (FE -SEM), Fourier-transform infrared (FT-IR) and x-ray powder diffraction (XRD) were used to characterize its morphology and structure. The electrochemical studies and measurements were carried out by using various techniques including cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CHA). The Ni-Co-LDH/MWCNTs nanocomposite-modified carbon paste electrode (Ni-Co-LDH/ MWCNTs/CPE) exhibited enhanced electrocatalytic performance for the determination of 4-aminophenol. Detection of 4-aminophenol was done by using DPV. According to the results of DPV, the Ni-Co-LDH/ MWCNTs/CPE sensor demonstrated a linear response to 4-aminophenol in the linear range of 0.02 -700.0 mu M, with a limit of detection (LOD) of 0.01 mu M, and a sensitivity of 0.076 mu A/ mu M. Also, the modified CPE presented reproducible and repeatable responses to determine 4 -AP. The prepared sensor was also applied for determination of 4-aminophenol in the presence of possible interfering species and good results were obtained. In addition, the sensor successfully detected 4-aminophenol in real water samples with recoveries ranging from 98.0 % to 104.0 %, and with relative standard deviation (RSD) below 3.3 %. Therefore, the obtained results indicate that the prepared sensor can be an effective tool for the simple, fast, and sensitive detection of 4-aminophenol in water samples.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Voltammetric sensing of paracetamol, dopamine and 4-aminophenol at a glassy carbon electrode coated with gold nanoparticles and an organophillic layered double hydroxide
    Huanshun Yin
    Kun Shang
    Xiaomeng Meng
    Shiyun Ai
    Microchimica Acta, 2011, 175 : 39 - 46
  • [2] Electrochemical sensor based on multi-walled carbon nanotubes for imidacloprid determination
    Bruzaca, Evellin E. S.
    de Oliveira, Raissa C.
    Duarte, Mateus S. S.
    Sousa, Camila P.
    Morais, Simone
    Correia, Adriana N.
    de Lima-Neto, Pedro
    ANALYTICAL METHODS, 2021, 13 (18) : 2124 - 2136
  • [3] Voltammetric sensing of paracetamol, dopamine and 4-aminophenol at a glassy carbon electrode coated with gold nanoparticles and an organophillic layered double hydroxide
    Yin, Huanshun
    Shang, Kun
    Meng, Xiaomeng
    Ai, Shiyun
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 39 - 46
  • [4] Voltammetric determination of quercetin at a multi-walled carbon nanotubes paste electrode
    Xiao, Ping
    Zhao, Faqiong
    Zeng, Baizhao
    MICROCHEMICAL JOURNAL, 2007, 85 (02) : 244 - 249
  • [5] Multi walled carbon nanotubes supported CuO-Au hybrid nanocomposite for the effective application towards the electrochemical determination of Acetaminophen and 4-Aminophenol
    Shaikshavali, P.
    Reddy, T. Madhusudana
    Palakollu, V. N.
    Karpoormath, R.
    Rao, Y. Subba
    Venkataprasad, G.
    Gopal, T. Venu
    Gopal, P.
    SYNTHETIC METALS, 2019, 252 : 29 - 39
  • [6] A composite structural supercapacitor based on Ni-Co-layered double hydroxide-coated carbon cloth electrodes
    Zhou, Hanmo
    Duongthipthewa, Anchalee
    Zhang, Jing
    Li, Hao
    Peng, Luwei
    Fu, Yu
    Huang, Haitao
    Zhou, Limin
    COMPOSITES SCIENCE AND TECHNOLOGY, 2023, 240
  • [7] Synthesis of magnetic multi-walled carbon nanotubes with layered double hydroxide (M-MWCNTs@MnAl-LDH) nanocomposite as an adsorbent for lead extraction
    Arain, Muhammad Balal
    Soylak, Mustafa
    FOOD CHEMISTRY, 2025, 463
  • [8] A chiral electrochemical sensor for propranolol based on multi-walled carbon nanotubes/ionic liquids nanocomposite
    Chen, Lisha
    Li, Kunlin
    Zhu, Hong
    Meng, Lingchen
    Chen, Jitao
    Li, Meixian
    Zhu, Zhiwei
    TALANTA, 2013, 105 : 250 - 254
  • [9] A novel sensor of poly (vinyl alcohol) incorporated multi-walled carbon nanotubes for voltammetric determination of Cu (II)
    Chi, Deling
    Zhao, Kai
    Zhang, Feifei
    Wang, Zonghua
    ADVANCED RESEARCH ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2012, 600 : 124 - +
  • [10] Fabrication of an electrochemical sensor based on magnetic multi-walled carbon nanotubes for the determination of ciprofloxacin
    Bagheri, H.
    Khoshsafar, H.
    Amidi, S.
    Ardakani, Y. Hosseinzadeh
    ANALYTICAL METHODS, 2016, 8 (16) : 3383 - 3390