Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees

被引:0
|
作者
Vahabi, Arman [1 ]
Er, Erdem [2 ]
Bicer, Elcil Kaya [1 ]
Sahin, Fahri [3 ]
Kavakli, Kaan [4 ]
Aydogdu, Semih [1 ]
机构
[1] Ege Univ, Sch Med, Dept Orthoped & Traumatol, Izmir, Turkiye
[2] Kars Harakani State Hosp, Dept Orthopaed & Traumatol, Kars, Turkiye
[3] Ege Univ, Fac Med, Dept Internal Med, Div Hematol, Izmir, Turkiye
[4] Ege Univ, Fac Med, Dept Pediat, Div Hematooncol, Izmir, Turkiye
关键词
2D templating; correlation; haemophilic arthropathy; preoperative planning; COMPONENT;
D O I
10.1111/hae.15072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionIn total knee arthroplasty (TKA), choosing the correct implant size is important. There is lack of data on accuracy of templating on haemophilic knees. Our aim was to test the accuracy of 2D digital templating for TKA on haemophilic arthropathy (HA) of knee.Materials and MethodsTKAs performed on HA between January 2011 and January 2022 were screened. Osteoarthritis (OA) group was created as control group by a one-to-one matching regarding type of implant used. Intra- and interobserver correlations were measured in HA, then correlation between templated and implanted sizes was investigated in four assessments (femur AP, femur lateral, tibia AP, tibia lateral), then compared with OA group. Fifty-eight knees in each group included.ResultsRegarding intraobserver correlation in HA, there was excellent correlation for femur AP [.93 (.73-.98)], femur lateral [.98 (.91-.99)], and tibia AP (1.0) templating. Regarding interobserver correlation in HA, excellent correlation was observed for femur lateral [.93 (.74-.98)] and tibia AP templating [.90 (.65-.97)]. Regarding correlation of templated and applied sizes in HA; tibia AP, tibia lateral and femur lateral templating showed good correlation [.81 (.70-.89), .86 (.77-.91), .79 (.67-.87) while femur AP templating showed moderate correlation [.67 (.50-.79)]. Comparing HA and OA, there was no difference in correlation levels regarding femur AP, femur lateral, tibia AP and tibia lateral templating (p = .056, p = .781, p = .761, p = .083, respectively).ConclusionAlthough 2D digital templating shows comparable correlation in HA and OA, clinical applicability of templating on HA appears to be limited in its current state.
引用
收藏
页码:1043 / 1049
页数:7
相关论文
共 50 条
  • [1] Outcome after total knee arthroplasty in haemophilic patients with stiff knees
    Strauss, A. C.
    Schmolders, J.
    Friedrich, M. J.
    Pflugmacher, R.
    Mueller, M. C.
    Goldmann, G.
    Oldenburg, J.
    Pennekamp, P. H.
    HAEMOPHILIA, 2015, 21 (04) : E300 - E305
  • [2] ACCURACY OF DIGITAL TEMPLATING IN TOTAL HIP ARTHROPLASTY
    Holzer, L. A.
    Scholler, G.
    Friesenbichler, J.
    Maurer-Ertl, W.
    Leithner, A.
    OSTEOPOROSIS INTERNATIONAL, 2019, 30 : S254 - S255
  • [3] Effect of Training Level on Accuracy of Digital Templating in Primary Total Hip and Knee Arthroplasty
    Hsu, Andrew R.
    Kim, Jeffrey D.
    Bhatia, Sanjeev
    Levine, Brett R.
    ORTHOPEDICS, 2012, 35 (02) : E179 - E183
  • [4] A comparison of acetate and digital templating for total knee arthroplasty
    Specht, Lawrence M.
    Levitz, Seth
    Healy, William L.
    Tilzey, John F.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) : 179 - 183
  • [5] The accuracy of digital templating in uncemented total hip arthroplasty
    Lukas A. Holzer
    Georg Scholler
    Stefan Wagner
    Jörg Friesenbichler
    Werner Maurer-Ertl
    Andreas Leithner
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 263 - 268
  • [6] The accuracy of digital templating in uncemented total hip arthroplasty
    Holzer, Lukas A.
    Scholler, Georg
    Wagner, Stefan
    Friesenbichler, Joerg
    Maurer-Ertl, Werner
    Leithner, Andreas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (02) : 263 - 268
  • [7] The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty
    Gamble, Patrick
    de Beer, Justin
    Petruccelli, Danielle
    Winemaker, Mitchell
    JOURNAL OF ARTHROPLASTY, 2010, 25 (04): : 529 - 532
  • [8] The indication of a VY-Quadricepsplasty for total knee arthroplasty in haemophilic patients with stiff knees
    Ono, Kumiko
    Noguchi, Megumi
    Asano, Kayoko
    Takedani, Hideyuki
    HAEMOPHILIA, 2020, 26 : 52 - 52
  • [9] The reliability and accuracy of digital templating in total knee replacement
    Trickett, R. W.
    Hodgson, P.
    Forster, M. C.
    Robertson, A.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (07): : 903 - 906
  • [10] Total knee arthroplasty in haemophilic patients
    Dikici, F.
    Bayansalduz, A.
    Taier, O.
    Zuelfikar, B.
    HAEMOPHILIA, 2008, 14 : 79 - 79