A Comparative Evaluation of Stress Distribution Around Different Widths of Implant and Bony Interface in Function During Axial and Non-axial Loading: A Finite Element Analysis

被引:0
|
作者
Pai, Deepika R. [1 ]
Prabhu, Damodar M. [2 ]
Sameeh, Abdul [3 ]
Soman, Ajay [4 ]
Thomas, Anjana [5 ]
Koruthu, Anil Varghese [6 ]
机构
[1] Century Int Inst Dent Sci & Res Ctr, Dept Prosthodont Crown & Bridge, Poinachi, India
[2] W Ctr Prevent Hlth Care, Dept Internal Med, Mangalore, India
[3] Malabar Dent Coll & Res Ctr, Dept Prosthodont Crown & Bridge, Malappuram, India
[4] Al Azhar Dent Coll, Dept Prosthodont Crown & Bridge, Thodupuzha, India
[5] Annoor Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Ernakulam, India
[6] Royal Dent Coll, Dept Prosthodont Crown & Bridge, Palakkad, India
关键词
implant diameter; finite element analysis; cortical bone; cancellous bone; axial load;
D O I
10.7759/cureus.62674
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The study employed three-dimensional (3D) finite element analysis (FEA) and examined how implant diameters affect stress distribution across the implant -bone contact and how stress transmission through this interface changes during axial and non -axial loading. Materials and methods: A 3D mandibular model was created using cone beam CT of a patient with implants inserted into the first mandible molar. Nobel Biocare implants (Nobel Biocare, Switzerland) with specific dimensions of 3.5 mm, 4.3 mm, 5.0 mm, and 6.0 mm were chosen. Models were created in CATIAV5R19 (Dassault Systemes, France) from threaded titanium implant dimensions. Implants were finite elementmodeled utilizing ANSYS Workbench v11.0 (Ansys, Inc, Pennsylvania, USA). The analysis involved applying 100 N axial, 50 N buccolingual, and 50 N mesiodistal loads. Results: In a lower first molar bone segment, the implant top surface was loaded in 100 N axial, 50 N buccolingual, and 50 N mesiodistal orientations. The cortical bone proximal to the implant neck had the most von Mises stress, regardless of model or stress scenario. In Model I cortical bone, maximal stress was centered at the implant neck. Most stress was on lingual bone plates, lesser on buccal, and least on mesial and distal. Less than half of the implant stress was transmitted to the cortical bone. The stress transferred from the implant to the cortical bone in Model II was less than half of the implant stress. The same was true for Models III and IV. In Model I cancellous bone, stress was concentrated in the implant's coronal half and minimal in the apical half. Conclusion: The stress patterns under axial loading were distributed favorably. Therefore, it can be inferred that an augmentation in the diameter of the implant enhances the even distribution of stress at the interface between the bone and the implant by offering a larger surface area for the dispersion of stress. Furthermore, it was determined that applying force along an implant's axis was a beneficial loading direction and did not negatively impact its lifespan.
引用
收藏
页数:9
相关论文
共 41 条
  • [1] Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis
    Oliveira, Helder
    Velasco, Aritza Brizuela
    Rios-Santos, Jose-Vicente
    Lasheras, Fernando Sanchez
    Lemos, Bernardo Ferreira
    Gil, Francisco Javier
    Carvalho, Alexandrine
    Herrero-Climent, Mariano
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (13) : 1 - 17
  • [2] Effect of different implant locations and abutment types on stress and strain distribution under non-axial loading: A 3-dimensional finite element analysis
    Sakar, Didem
    Guncu, Mustafa Baris
    Arikan, Hale
    Muhtarogullari, Mehmet
    Aktas, Guliz
    Reiss, Natalia
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 607 - 613
  • [3] Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    Barbier, L
    Vander Sloten, J
    Krzesinski, G
    Schepers, E
    Van Der Perre, G
    JOURNAL OF ORAL REHABILITATION, 1998, 25 (11) : 847 - 858
  • [4] Comparative finite element analysis of a normal dentition with a single implant-supported crown influenced by axial-non axial loading
    Georgiopoulos, B
    Provatidis, C
    Galanis, C
    Sfantsikopoulos, M
    Kafantaris, N
    Koidis, P
    PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 254 - 259
  • [5] Comparative Evaluation of Three Abutment-Implant Interfaces on Stress Distribution in and Around Different Implant Systems: A Finite Element Analysis
    Kharsan, Vishwas
    Bandgar, Vaibhav
    Mirza, Aftab
    Jagtiani, Kiran
    Dhariwal, Neha
    Kore, Rahul
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (04) : 590 - 594
  • [6] Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function
    Papavasiliou, G
    Kamposiora, P
    Bayne, SC
    Felton, DA
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (06): : 633 - 640
  • [7] The effect of different occlusal contact situations on peri-implant bone stress - A contact finite element analysis of indirect axial loading
    Brune, Annike
    Stiesch, Meike
    Eisenburger, Michael
    Greuling, Andreas
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 99 : 367 - 373
  • [8] A comparative finite element analysis of two types of axial and radial functionally graded dental implants with titanium one around implant-bone interface
    Shirazi, Hadi Asgharzadeh
    Ayatollahi, Majidreza
    Karimi, Alireza
    Navidbakhsh, Mahdi
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2017, 24 (05) : 747 - 754
  • [9] Finite Element Analysis of Compressive Stress and Strain of Different Implant Forms During Vertical Loading
    Tanasic, I.
    Tihacek-Sojic, L.
    Milic-Lemic, A.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2014, 17 (02) : 125 - 133
  • [10] Finite Element Analysis and Experimental Investigations on Stress Distribution of Dental Implants around Implant-Bone Interface
    Dhatrak, Pankaj
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 5641 - 5648