Experimental study of R410A and its low GWP alternative R452B flow boiling in a multiport microchannel tube

被引:0
|
作者
Liu, Hequn [1 ,2 ]
Wu, Zhenxing [1 ,2 ]
Yuan, Chao [1 ,2 ]
Li, Houpei [1 ,2 ,3 ]
Li, Hongqiang [1 ,2 ]
Peng, Jinqing [1 ,2 ]
Huang, Long [4 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha, Peoples R China
[3] Univ Illinois, Air Conditioning & Refrigerat Ctr, Dept Mech Engn, Urbana, IL 61801 USA
[4] Xian Jiaotong Liverpool Univ, Suzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Flow boiling; R452B; R410A; Microchannel; HEAT-TRANSFER COEFFICIENT; FRICTIONAL PRESSURE-DROP; 2-PHASE FLOW; GENERAL CORRELATION; R32; EVAPORATION; MINI/MICRO; PREDICTION; MIXTURES; DIAMETER;
D O I
10.1016/j.ijheatmasstransfer.2024.125732
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigated the flow boiling performance of the refrigerants R410A and its low Global Warming Potential (GWP) alternative R452B in a multiport microchannel tube. Heat transfer coefficient (HTC) and pressure gradient (dP/dz) for the two refrigerants were measured. The experiments covered a range of mass flux from 100 to 250 kg m- 2s- 1, heat flux from 2 to 8 kW m- 2, and inlet temperatures from 0 to 20 degrees C. This study analyzed the effect of vapor quality, mass flux, heat flux, and saturation pressure on HTC and dP/dz. Additionally, the study also employed a Pearson correlation coefficient analysis to reveal the influence of these conditions on refrigerant performance. The Pearson method provided insights into the nonlinear relationships between the tested parameters and their impact on the heat transfer and flow characteristics. Experimental results were compared with predictive models to validate their applicability in practical scenarios. The comparison led to a recommendation of models. Kim and Mudawar and Bertsch et al. models for predicting the pressure gradient and heat transfer coefficient, respectively, were highlighted for their predictive accuracy.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Experimental evaluation of R32, R452B and R454B as alternative refrigerants for R410A in a refrigeration system
    Panato, Victor Hugo
    Pico, David Fernando Marcucci
    Bandarra Filho, Enio Pedone
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 135 : 221 - 230
  • [2] Drop-in performance of the low-GWP alternative refrigerants R452B and R454B in an R410A liquid-to-water heat pump
    Sieres, Jaime
    Ortega, Ignacio
    Cerdeira, Fernando
    Alvarez, Estrella
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [3] Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers
    Shen, Bo
    Li, Zhenning
    Gluesenkamp, Kyle R.
    APPLIED THERMAL ENGINEERING, 2022, 204
  • [4] 替代R410A低GWP制冷剂R454B和R452B的特性研究
    王晓东
    马麟
    姚文虎
    马海云
    制冷与空调, 2020, 20 (09) : 85 - 89
  • [5] Performance of an Air-Cooled Chiller with R410A Alternatives R452B and R32
    Schultz, Kenneth
    Nayak, Gurudath
    2017 ASHRAE ANNUAL CONFERENCE PAPERS, 2017,
  • [6] Experimental study of falling film evaporation of refrigerants, R32 R1234yf, R410A, R452B and R454B on horizontal tubes
    Hsu, Chien-Yeh
    Chien, Liang-Han
    Chang, Jan-Cheng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 205
  • [7] Experimental study of R134a and its alternative mixture R450A flow boiling in a microchannel tube
    Yuan, Chao
    Jin, Shenghan
    Li, Hongqiang
    Liu, Zhongbin
    Peng, Jinqing
    Li, Houpei
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [8] Experimental study on flow boiling of R134a and R410A in a horizontal microfin tube at high saturation temperatures
    Padovan, Andrea
    Del Col, Davide
    Rossetto, Luisa
    APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) : 3814 - 3826
  • [9] Numerical and experimental evaluation of flow boiling heat transfer in microchannels for R452B refrigerant
    Lee, Yee-Ting
    Wang, I-Ju
    Su, Jung-Jung
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 231
  • [10] R410A的低GWP替代制冷剂R452B在屋顶式空调机组上的性能评估
    刘卫东
    制冷与空调, 2018, (07) : 34 - 38