Objective: To compare the effect of a new complete robot-assisted total hip arthroplasty (RA-THA) with that of the manual total hip arthroplasty (MTHA) and to verify the accuracy and safety of the former. Methods: Overall, 148 patients were enroled from 3 March 2021 to 28 December 2021 in this study and classified into RA-THA (n=74 patients) and MTHA (n=74 patients) groups. The sex, age, operative side, BMI, diagnosis, other basic information, operative time, acetabular prosthesis anteversion and inclination, femoral prosthesis anteversion and angulation, femoral prosthesis filling rate, leg length discrepancy (LLD), Harris hip score, and visual analogue scale (VAS) score of the two groups were compared. Results: No significant differences were observed in the two groups regarding sex, age, operative side, BMI, diagnosis, Harris hip score, VAS score, acetabular inclination, acetabular prosthesis anteversion, femoral prosthesis anteversion, combined anteversion, and femoral prosthesis filling rate (P>0.05). The operative time was significantly longer in the RA-THA group than in the MTHA group (106.71 +/- 25.22 min vs. 79.42 +/- 16.16 min; t=7.30, P<0.05). The femoral angulation (1.78 degrees +/- 0.64 degrees) and LLD (2.87 +/- 1.55 mm) in the RA-THA group were significantly lesser than those in the MTHA group (2.22 degrees +/- 1.11 degrees and 5.81 +/- 6.27 mm, respectively; t=-2.95 and t=-3.88, P<0.05). Conclusion: The complete RA-THA has some advantages over the traditional procedure in restoring the lower limb length and controlling the femoral prosthesis angulation. Thus, this study verifies the accuracy and safety of the robot-assisted system.
引用
收藏
页码:2141 / 2150
页数:10
相关论文
共 50 条
  • [1] A commentary on 'A new designed full process coverage robot-assisted total hip arthroplasty: a multicentre randomized clinical trial'
    Li, Shu
    Bao, Yong-Gang
    Wu, Bin
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (08) : 5284 - 5285
  • [2] A commentary on 'A new designed full process coverage robot-assisted total hip arthroplasty: a multicenter randomized clinical trial'
    Yan, Zheng
    Xu, Yan
    Wu, Lianguo
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (08) : 5216 - 5217
  • [3] Robot-assisted total hip arthroplasty
    Banerjee, Samik
    Cherian, Jeffery J.
    Elmallah, Randa K.
    Pierce, Todd P.
    Jauregui, Julio J.
    Mont, Michael A.
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (01) : 47 - 56
  • [4] Robot-assisted total hip arthroplasty: Clinical outcomes and complication rate
    Perets, Itay
    Walsh, John P.
    Close, Mary R.
    Mu, Brian H.
    Yuen, Leslie C.
    Domb, Benjamin G.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (04):
  • [5] Radiographic evaluation of robot-assisted versus manual total hip arthroplasty: a multicenter randomized controlled trial
    Zhang, Xianzuo
    Shen, Xianyue
    Zhang, Rongwei
    Chen, Mo
    Ma, Ruixiang
    Zhang, Zian
    Zhang, Haining
    Yang, Bo
    Zhu, Chen
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 25 (01)
  • [6] Robot-Assisted Total Hip Arthroplasty for Arthrodesed Hips
    Chai, Wei
    Kong, Xiangpeng
    Yang, Minzhi
    Puah, Ken Lee
    Tang, Peifu
    Chen, Jiying
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2020, 16 : 357 - 368
  • [7] The learning curve of a novel seven-axis robot-assisted total hip arthroplasty system: a randomized controlled trial
    Sun, Haocheng
    Lu, Hanpeng
    Xiao, Qiang
    Ding, Zichuan
    Luo, Zeyu
    Zhou, Zongke
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [8] The Cost of Robot-assisted Total Hip Arthroplasty: Comparing Safety and Hospital Charges to Conventional Total Hip Arthroplasty
    Kirchner, Gregory J.
    Lieber, Alexander M.
    Haislup, Brett
    Kerbel, Yehuda E.
    Moretti, Vincent M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (14) : 609 - 615
  • [9] Multicentre randomized clinical trial on robot-assisted versus video-assisted thoracoscopic oesophagectomy (REVATE trial)
    Chao, Yin-Kai
    Li, Zhigang
    Jiang, Hongjing
    Wen, Yu-Wen
    Chiu, Chen-Hung
    Li, Bin
    Shang, Xiaobin
    Fang, Tuan-Jen
    Yang, Yang
    Yue, Jie
    Zhang, Xiaobin
    Zhang, Chen
    Liu, Yun-Hen
    BRITISH JOURNAL OF SURGERY, 2024, 111 (07)
  • [10] Impact of surgeon handedness in manual and robot-assisted total hip arthroplasty
    Kong, Xiangpeng
    Yang, Minzhi
    Li, Xiang
    Ni, Ming
    Zhang, Guoqiang
    Chen, Jiying
    Chai, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)