Skylight VIS-NIR Polarization Radiometer: Design, Calibration, and Measurement

被引:0
|
作者
Li, Shuai [1 ,2 ]
Wang, Rui [3 ]
Cheng, Jiuming [1 ,2 ]
Xu, Wenqing [1 ]
Xu, Gang [1 ]
Dai, Congming [1 ]
Wei, Heli [1 ]
Zhan, Jie [1 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Atmospher Opt, HFIPS, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Peoples R China
[3] Anhui Univ, Inst Phys Sci & Informat Technol, Hefei 230601, Peoples R China
关键词
Polarimetric calibration; skylight polarization measurements; spectral polarization sensor; sun radiometer; SKY; SUN; AEROSOLS; SOLAR; MODEL;
D O I
10.1109/JSEN.2024.3360241
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Skylight polarization radiation measurement has important application value in atmospheric remote sensing, aerosol retrieval, and polarization navigation. Traditional instruments like the Cimel CE318, while widely used in AERONET and SONET networks, suffer from limitations, such as long measurement time resolution, limited measurement modes, and incomplete calibration. Addressing these gaps, this article designs and implements a Skylight VIS-NIR Polarization Radiometer (SVNPR) for precise spectral polarization measurements, covering a spectral range of 400-1100 nm. The SVNPR, based on ground-based passive, robust, constant-temperature, and multiscan features, is particularly suited for field deployment. Furthermore, a comprehensive and feasible indoor calibration scheme is proposed, including spectral calibration, radiometric calibration, and polarimetric calibration. Finally, field measurements were conducted, and the experimental results show that the SVNPR can achieve effective and accurate skylight polarization measurements in practical applications. The calibrated instrument showed good consistency with CE318-DP, with mean absolute deviation (MAD) and root mean square error (RMSE) both within 0.005.
引用
收藏
页码:7700 / 7710
页数:11
相关论文
共 50 条
  • [1] Skylight VIS-NIR Polarization Radiometer: Design, Calibration, and Measurement
    Anhui Institute of Optics and Fine Mechanics, Hfips, Chinese Academy of Sciences, Key Laboratory of Atmospheric Optics, Hefei
    230031, China
    不详
    230026, China
    不详
    230601, China
    IEEE Sensors J., 6 (7700-7710):
  • [2] Design of skylight polarization measurement system
    Cui, Yan
    Cao, Nan-Nan
    Chu, Jin-Kui
    Zhao, Kai-Chun
    Wang, Ti-Chang
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (06): : 1431 - 1435
  • [3] Passive calibration board for alignment of VIS-NIR, SWIR and LWIR images
    St-Laurent, L.
    Mikhnevich, M.
    Bubel, A.
    Prevost, D.
    13TH QUANTITATIVE INFRARED THERMOGRAPHY CONFERENCE, 2016, : 777 - 784
  • [4] Transfer learning to localise a continental soil vis-NIR calibration model
    Padarian, J.
    Minasny, B.
    McBratney, A. B.
    GEODERMA, 2019, 340 : 279 - 288
  • [5] Passive calibration board for alignment of VIS-NIR, SWIR and LWIR images
    St-Laurent, L.
    Mikhnevich, M.
    Bubel, A.
    Prevost, D.
    QUANTITATIVE INFRARED THERMOGRAPHY JOURNAL, 2017, 14 (02) : 193 - 205
  • [6] Calibration procedures and measurement results of a fast semi-hemispherical spectro-radiometer in VIS and NIR
    Hahlweg, C
    Rothe, H
    IMAGING SPECTROMETRY X, 2004, 5546 : 233 - 243
  • [7] Design of a aberration-corrected VIS-NIR imaging spectrograph
    Chuang, Kai-Ping
    Wang, Hau-Wei
    Yang, Fu-Shiang
    OPTICS COMMUNICATIONS, 2007, 272 (02) : 330 - 335
  • [8] Long-term autonomous vicarious calibration of VIS-NIR channels of MODIS
    Qiu, Ganggang
    Liu, Jinhui
    Lv, Wenfa
    Wei, Wei
    Zhang, Meng
    SIXTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATIONS, 2020, 11455
  • [9] Multiproduct, Multicomponent and Multivariate Calibration: a Case Study by Using Vis-NIR Spectroscopy
    Dayane Aparecida dos Santos
    Karen Priscila de Lima
    Vinícius Cavalcante
    Aline Coqueiro
    Marcilene Ferrari Barriquello Consolin
    Nelson Consolin Filho
    Paulo Henrique Março
    Patrícia Valderrama
    Food Analytical Methods, 2018, 11 : 1915 - 1919
  • [10] Multiproduct, Multicomponent and Multivariate Calibration: a Case Study by Using Vis-NIR Spectroscopy
    dos Santos, Dayane Aparecida
    de Lima, Karen Priscila
    Cavalcante, Vinicius
    Coqueiro, Aline
    Barriquello Consolin, Marcilene Ferrari
    Consolin Filho, Nelson
    Marco, Paulo Henrique
    Valderrama, Patricia
    FOOD ANALYTICAL METHODS, 2018, 11 (07) : 1915 - 1919