Comparison of 2 different fixation techniques of comminuted acetabular quadrilateral surface fractures using square bracket-shaped tubular plate or interfragmentary screws in addition to supra/infrapectineal plate fixation: An observational study

被引:1
|
作者
Kilinc, Cem Yalin [1 ]
Gultac, Emre [2 ]
Can, Fatih Ilker [3 ]
Kilinc, Rabia Mihriban [4 ]
Sener, Burak [3 ]
Acan, Ahmet Emrah [5 ]
机构
[1] Caria Orthoped & Rehabil Clin, Hasan Ercan Cd 15 B, TR-48000 Mugla, Turkiye
[2] Mugla Sitki Kocman Univ, Fac Med, Dept Orthoped & Traumatol, Mugla, Turkiye
[3] Mugla Training & Res Hosp, Orthoped & Traumatol Clin, Mugla, Turkiye
[4] Mugla Sitki Kocman Univ, Fac Med, Dept Radiol, Mugla, Turkiye
[5] Balikesir Univ, Fac Med, Dept Orthoped & Traumatol, Balikesir, Turkiye
关键词
acetabulum quadrilateral surface fractures; functional scores; interfragmentary lag screw; radiological scores; SBST plate; REDUCTION;
D O I
10.1097/MD.0000000000038252
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The management of comminuted quadrilateral fractures remains challenging, and treatment options are constantly evolving. The purpose of the present study was to examine the outcomes of 2 different fixation techniques in the management of comminuted quadrilateral fractures. Twenty-two patients with comminuted quadrilateral acetabular fractures were surgically treated with interfragmentary lag screw (group 1) and square bracket-shaped tubular (SBST) plate technique (group 2), in addition to suprapectineal and infrapectineal pelvic reconstruction plate fixation between January 2016 and July 2019 at our clinic. 2 years follow-up control data of each group were compared in terms of radiological and functional results, and complications. According to the functional score comparison, the mean Merle d'Aubigne Postel scoring system (MAP) score was 15.2/15.6 (P = .632), and the mean Harris hip scoring (HHS) system score was 74.65/77.3 (P = .664) in groups 1 and 2, respectively. Radiological comparison was performed according to matta radiological criteria (MRC), and 2 excellent, 6 good, 2 poor, 4 excellent, 4 good, and 4 poor radiological results were observed in groups 1 and 2, respectively. intraarticular screw penetration was detected in 3 patients in group 1, while there was no articular implant penetration in group 2 (P = .001). We believe that satisfactory results can be obtained with the SBST plate technique, offering functional and clinical outcomes that are similar to those of the interfragmentary screw technique. The SBST plate technique is superior in terms of avoiding intraarticular screw penetration and related revision surgery.
引用
收藏
页数:6
相关论文
empty
未找到相关数据