Comparison of 3D Magnetization-transfer- and Spectral-presaturation-with-inversion-recovery-based Neuromelanin Imaging

被引:0
|
作者
Kusama, Midori [1 ]
Kimura, Yukio [1 ]
Yoneyama, Masami [2 ]
Namiki, Takashi [2 ]
Tamaru, Takeshi [1 ]
Miyagi, Kenji [1 ]
Sato, Noriko [1 ]
机构
[1] Natl Ctr Neurol & Psychiat, Dept Radiol, Kodaira, Tokyo, Japan
[2] Philips Japan, Tokyo, Japan
关键词
magnetization transfer; neuromelanin imaging; spectral presaturation with inversion recovery; three-dimensional imaging; SUBSTANTIA-NIGRA; LOCUS-COERULEUS; MRI; DIAGNOSIS; VISUALIZATION; CONTRAST; DISEASE;
D O I
10.2463/mrms.mp.2023-0095
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Neuromelanin is visualized by optimizing the conditions of longitudinal relaxation (T1)-weighted imaging (T1WI). Although it was originally developed in 2D imaging, 3D imaging has been also reported, and T1WI sequences with magnetization transfer (MT) pulses are now widely used in 3D gradient echo (GRE) sequences. In this study, we assert that the use of spectral presaturation with inversion recovery (SPIR) may also be useful as an alternative to MT pulses, and we optimize SPIR and compare it with MT. Methods: Neuromelanin images with MT pulse and SPIR (flip angles [FAs] = 19 degrees, 22 degrees, and 25 degrees) were acquired from 30 healthy volunteers. To achieve the same acquisition time of 5 min, the slab thickness of the MT images was less than 1/3 of those of the SPIR images; the acquisition areas for MT and SPIR were the brainstem and the whole brain, respectively. Visual and quantitative evaluation was performed and compared on the four sequences acquired for the substantia nigra pars compacta (SNc) and the locus coeruleus (LC). For visual assessment, we used the mean score from a 3-point scale by two evaluators. For quantitative evaluation, the contrast ratios of SNc and LC were calculated in comparison with the background tissue signal. Results: In visual assessments, the mean scores of the SPIR FA19 degrees and FA22 degrees images were better than others in the SNc. Regarding LC, the SPIR FA22 degrees image yielded the best mean score. In quantitative evaluations, the MT image was significantly lower than the other three images in SNc. Regarding LC, there were no significant differences among the four acquired images (MT and SPIR FA19 degrees, FA22 degrees, and FA25 degrees). Conclusions: Detection of neuromelanin in SNc and LC was improved by the use of SPIR compared to MT pulse in 3D neuromelanin imaging.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Rapid whole-brain quantitative magnetization transfer imaging using 3D selective inversion recovery sequences
    Cronin, Matthew J.
    Xu, Junzhong
    Bagnato, Francesca
    Gochberg, Daniel F.
    Gore, John C.
    Dortch, Richard D.
    MAGNETIC RESONANCE IMAGING, 2020, 68 : 66 - 74
  • [2] EVALUATION OF SUSPECTED MUSCULOSKELETAL NEOPLASMS USING 3D T2-WEIGHTED SPECTRAL PRESATURATION WITH INVERSION-RECOVERY
    TERK, MR
    GOBER, JR
    DEVERDIER, H
    SIMON, HE
    COLLETTI, PM
    MAGNETIC RESONANCE IMAGING, 1993, 11 (07) : 931 - 939
  • [3] Comparison of Magnetization Transfer Imaging and CPMG for 3D Polymer Gel Dosimetry
    Kubo, H.
    Watanabe, Y.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Quantitative Magnetization Transfer Imaging in Human Brain at 3 T via Selective Inversion Recovery
    Dortch, Richard D.
    Li, Ke
    Gochberg, Daniel F.
    Welch, E. Brian
    Dula, Adrienne N.
    Tamhane, Ashish A.
    Gore, John C.
    Smith, Seth A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (05) : 1346 - 1352
  • [5] Simultaneous 3D quantitative magnetization transfer imaging and susceptibility mapping
    Jang, Albert
    Chan, Kwok-Shing
    Mareyam, Azma
    Stockmann, Jason
    Huang, Susie Yi
    Wang, Nian
    Jang, Hyungseok
    Lee, Hong-Hsi
    Liu, Fang
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [6] An Improved 3D Magnetization Inversion Based on Smoothness Constraints in Spherical Coordinates
    Zhang, Liang
    Lu, Guangyin
    Zhu, Ziqiang
    Cao, Shujin
    MAGNETOCHEMISTRY, 2022, 8 (11)
  • [7] Comparison of 3D Double Inversion Recovery (DIR) versus 3D Fluid Attenuated Inversion Recovery (FLAIR) in precise diagnosis of acute optic neuritis
    Murumkar, Vivek
    Baishya, Priyanka Priyadarshini
    Kulanthaivelu, Karthik
    Saini, Jitender
    Manjunath, Netravathi
    Gupta, Rakesh Kumar
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [8] Imaging iron and neuromelanin simultaneously using a single 3D gradient echo magnetization transfer sequence: Combining neuromelanin, iron and the nigrosome-1 sign as complementary imaging biomarkers in early stage Parkinson's disease
    He, Naying
    Ghassaban, Kiarash
    Huang, Pei
    Jokar, Mojtaba
    Wang, Ying
    Cheng, Zenghui
    Jin, Zhijia
    Li, Yan
    Sethi, Sean K.
    He, Yixi
    Chen, Yongsheng
    Gharabaghi, Sara
    Chen, Shengdi
    Yan, Fuhua
    Haacke, E. Mark
    NEUROIMAGE, 2021, 230
  • [9] Selective inversion recovery quantitative magnetization transfer imaging: Toward a 3 T clinical application in multiple sclerosis
    Bagnato, Francesca
    Franco, Giulia
    Ye, Fei
    Fan, Run
    Commiskey, Patricia
    Smith, Seth A.
    Xu, Junzhong
    Dortch, Richard
    MULTIPLE SCLEROSIS JOURNAL, 2020, 26 (04) : 457 - 467
  • [10] Population-based prevalence of infarctions on 3D fluid-attenuated inversion recovery (FLAIR) imaging
    Cogswell, Petrice M.
    Aakre, Jeremiah A.
    Castillo, Anna M.
    Knopman, David S.
    Kantarci, Kejal
    Rabinstein, Alejandro A.
    Petersen, Ronald C.
    Clifford, R. Jack, Jr.
    Mielke, Michelle M.
    Vemuri, Prashanthi
    Graff-Radford, Jonathan
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (08):