A passive single-cylindrical neutron spectrometer for photoneutron spectrometry in 10 MV Elekta Precise Linac head

被引:3
|
作者
Tursinah, Rasito [1 ,2 ]
Permana, Sidik [1 ]
Suud, Zaki [1 ]
Maulana, Alan [2 ]
Sukmabuana, Putu [2 ]
Lesmana, Hadi [3 ]
Afham, Adib [4 ]
Laksono, Tri [5 ]
机构
[1] Bandung Inst Technol, Nucl & Sci Engn Dept, Jl Ganeca 10, Bandung, Indonesia
[2] Natl Res & Innovat Agcy, Res Org Nucl Energy, BJ Habibie Sci & Technol Pk, South Tangerang, Banten, Indonesia
[3] Indonesia Army Cent Hosp, Jl Kwini 1, Jakarta, Indonesia
[4] Natl Res & Innovat Agcy, Directorate Lab Management, Res Facil & Sci & Technol Areas, Jl Lebak Bulus 49, Jakarta, Indonesia
[5] Natl Res & Innovat Agcy, Directorate Nucl Energy Facil Management, Jl Tamansari 71, Bandung, Indonesia
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2024年 / 1065卷
关键词
Neutron spectrum; Spectrometer; Single-moderator; Linac head; Elekta Precise; RADIATION PROTECTION; MULTIDETECTOR; DESIGN; VARIAN; MODERATOR; DETECTOR; SPECTRA; PHITS; FIELD;
D O I
10.1016/j.nima.2024.169519
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Measuring the neutron spectrum on the Linac head using a passive type neutron detector is relatively easier than an active type detector because it does not require the involvement of operators who work in a high radiation area. Neutron spectrum measurements with passive foil activation neutron detectors in a single-moderator are more practical and easier than multi-foil techniques. This technique is quite simple, easy to make, low cost, and the measurement time is relatively short. This spectrometer is designed by placing seven passive Au detectors at varying depths in a single-cylindrical moderator. The response function for each detector is calculated by MCNPX 2.7 program and used ENDF7 as a nuclear data library. Detector foil activity was measured using a gamma spectrometer, and the neutron spectrum was obtained using the unfolding technique using the UMG 3.3 program. The results of measuring the neutron spectrum measurements have been carried out at a position 10 cm below the head of the Elekta Precise 10 MV Linac was 2.73 x 105 n/cm2 & sdot;s, where the fast neutron from these results are 4% higher when compared to the simulation results using PHITS.
引用
收藏
页数:7
相关论文
共 9 条
  • [1] Characterization of neutron spectrum at the neutron radiography of RSG-GAS reactor using a passive single-cylindrical neutron spectrometer
    Tursinah, Rasito
    Permana, Sidik
    Su'ud, Zaki
    Maulana, Alan
    Rivai, Abu Khalid
    Subekti, Muhammad
    Suyatno
    Ramdhani, Achmad
    Akbar, Fahrurrozi
    Muslih, M. Refai
    Wahyudi
    Istanto
    Prakoso, Djoko
    Ramadhani, M. F.
    Laksono, Tri C.
    Bunawas
    ANNALS OF NUCLEAR ENERGY, 2025, 215
  • [2] Characterization of neutron spectrum of polyethylene-moderated AmBe neutron source using a passive single-cylindrical neutron spectrometer
    Tursinah, Rasito
    Permana, Sidik
    Su'ud, Zaki
    Maulana, Alan
    Laksono, Tri C.
    Ikawati, Afida
    Setiawan, Satrio A.
    Wahyudi, Wahyudi
    Bunawas, Bunawas
    RADIATION MEASUREMENTS, 2024, 178
  • [3] Evaluation of photoneutron dose equivalent in 10 MV and 15 MV beams for wedge and open fields in the Elekta Versa HD linac
    Khilafath, Hajee Reyaz Ali Sahib
    Ganesan, Bharanidharan
    Sekar, Nandakumar
    Mohapatra, Dinakrushna
    Mahadevan, Pramod
    Vellingiri, Jayaprakash
    Prakasarao, Aruna
    Singaravelu, Ganesan
    APPLIED RADIATION AND ISOTOPES, 2022, 188
  • [4] MCNP5 evaluation of photoneutron production from the Alexandria University 15 MV Elekta Precise medical LINAC
    Abou-Taleb, W. M.
    Hassan, M. H.
    El Mallah, E. A.
    Kotb, S. M.
    APPLIED RADIATION AND ISOTOPES, 2018, 135 : 184 - 191
  • [5] Comparison and estimation of photoneutron dose produce between 10 MV flattened and unflattened beam in Elekta Versa HD™ medical linac
    Khilafath, Hajee Reyaz Ali Sahib
    Ganesan, Bharanidharan
    Sekar, Nandakumar
    Mohapatra, Dinakrushna
    Vellingiri, Jayaprakash
    Prakasarao, Aruna
    Mahadevan, Pramod
    Singaravelu, Ganesan
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (07) : 1899 - 1907
  • [6] Head scatter and surface/buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise accelerator
    Klein, E
    Esthappan, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1212 - 1212
  • [7] Determination of the neutron spectra around an 18 MV medical LINAC with a passive Bonner sphere spectrometer based on gold foils and TLD pairs
    Esposito, A.
    Bedogni, R.
    Lembo, L.
    Morelli, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 1038 - 1043
  • [8] Spectrometry of leakage photoneutrons of 18 MV medical accelerator head by Sohrabi passive multi-directional spherical neutron spectrometry system
    Sohrabi, Mehdi
    Hakimi, Amir
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 99 : 120 - 129
  • [9] Neutron spectrum measurements inside a self-shielded cyclotron during 18F production using a single-cylindrical neutron spectrometer with gold and indium activation foils
    Tursinah, Rasito
    Permana, Sidik
    Su'ud, Zaki
    Maulana, Alan
    Rivai, A. K.
    Santoso, Muhayatun
    Sukmabuana, Putu
    Nurhuda
    Suryanto, Hari
    Wahyudi
    Kusdiana
    Prakoso, Djoko
    Ramadhani, M. F.
    Bunawas
    ANNALS OF NUCLEAR ENERGY, 2025, 211