Prospective ECG-gated High-Pitch Photon-Counting CT Angiography: Evaluation of measurement accuracy for aortic annulus sizing in TAVR planning

被引:0
|
作者
Yang, Y. [1 ]
Richter, R. [1 ]
Halfmann, M. C. [1 ]
Graafen, D. [1 ]
Hell, M. [2 ]
Vecsey-Nagy, M. [3 ,4 ]
Laux, G. [2 ]
Kavermann, L. [2 ]
Jorg, T. [1 ]
Geyer, M. [2 ]
Varga-Szemes, A. [3 ]
Emrich, T. [1 ,3 ]
机构
[1] Univ Med Ctr Mainz, Dept Diagnost & Intervent Radiol, Langenbeckstr 1, D-55131 Mainz, Germany
[2] Univ Med Ctr Mainz, Dept Cardiol, Langenbeckstr 1, D-55131 Mainz, Germany
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, 25 Courtenay Dr, Charleston, SC 29425 USA
[4] Semmelweis Univ, Heart & Vasc Ctr, 68 Varosmajor St, H-1122 Budapest, Hungary
关键词
TAVR; Aortic annulus measurement; prospective ECG-gated high-pitch CTA; Photon Counting CT; INTERMEDIATE RISK PATIENTS; VALVE-REPLACEMENT; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; TRANSCATHETER; IMPLANTATION; STENOSIS; ARTIFACTS;
D O I
10.1016/j.ejrad.2024.111604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In planning transcatheter aortic valve replacement (TAVR), retrospective cardiac spiral-CT is recommended to measure aortic annulus with subsequent CT-angiography (CTA) to evaluate access routes. Photon- counting detector (PCD)-CT enables to assess the aortic annulus in desired cardiac phases, using prospective ECG-gated high-pitch CTA. The aim of this study was to evaluate the measurement accuracy of aortic annulus using prospective ECG-gated high-pitch CTA against retrospective spiral-CT reference. Method: Thirty patients underwent cardiac spiral-CT and prospective ECG-gated (30% R-R on aortic valve level) high-pitch CTA. Using propensity score matching, another 30 patients were identified whose CTA was performed using high-pitch mode without ECG-synchronization. Two investigators measured annular diameter, perimeter, and area on cardiac spiral-CT and high-pitch CTA. Results: The aortic valve was imaged in systole in 90 % of prospective ECG-gated CTA cases but only 50 % of non- ECG-gated CTA cases (p = 0.002). There was a strong correlation (r >= 0.94) without significant differences (p >= 0.09) between cardiac spiral-CT and prospective ECG-gated high-pitch CTA for all annulus measurements. In contrast, significant differences were found in annular short-axis diameter and area between cardiac spiral-CT and non-ECG-gated high-pitch CTA (p <= 0.03). Furthermore, prospective ECG-gated high-pitch CTA showed significantly reduced radiation exposure compared with cardiac spiral-CT (CTDI 4.52 vs. 24.10 mGy; p < 0.001). Conclusion: PCD-CT-based prospective ECG-gated high-pitch scans with targeted systolic acquisition at the level of the aortic valve can simultaneously visualize TAVR access routes and accurately measure systolic annulus size. This approach could aid in optimizing protocols to achieve lower radiation doses in the growing population of younger, low-risk TAVR patients.
引用
收藏
页数:8
相关论文
共 21 条
  • [1] Evaluation of ECG-Gated, High-Pitch Thoracoabdominal Angiographies With Dual-Source Photon-Counting Detector Computed Tomography
    Rippel, K.
    Luitjens, J.
    Habeeballah, O.
    Scheurig-Muenkler, C.
    Bette, Stefanie
    Braun, Franziska
    Kroencke, T. J.
    Schwarz, F.
    Decker, J. A.
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [2] Imaging of the aortic root on high-pitch non-gated and ECG-gated CT: awareness is the key!
    Prashant Nagpal
    Mukta D. Agrawal
    Sachin S. Saboo
    Sandeep Hedgire
    Sarv Priya
    Michael L. Steigner
    Insights into Imaging, 11
  • [3] Imaging of the aortic root on high-pitch non-gated and ECG-gated CT: awareness is the key!
    Nagpal, Prashant
    Agrawal, Mukta D.
    Saboo, Sachin S.
    Hedgire, Sandeep
    Priya, Sarv
    Steigner, Michael L.
    INSIGHTS INTO IMAGING, 2020, 11 (01)
  • [4] Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR
    Shnayien, Seyd
    Beetz, Nick Lasse
    Bressem, Keno Kyrill
    Hamm, Bernd
    Niehues, Stefan Markus
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (02): : 139 - 147
  • [5] ECG-gated Versus Non-ECG-gated High-pitch Dual-source CT for Whole Body CT Angiography (CTA)
    Beeres, Martin
    Wichmann, Julian L.
    Frellesen, Claudia
    Bucher, Andreas M.
    Albrecht, Moritz
    Scholtz, Jan-Erik
    Nour-Eldin, Nour-Eldin A.
    Gruber-Rouh, Tatjana
    Lee, Clara
    Vogl, Thomas J.
    Lehnert, Thomas
    ACADEMIC RADIOLOGY, 2016, 23 (02) : 163 - 167
  • [6] Photon-counting CT-angiography in pre-TAVR aortic annulus assessment: effects of retrospective vs. prospective ECG-synchronization on prosthesis valve selection
    Muhammad Taha Hagar
    Theresa Kluemper
    Manuel Hein
    Constantin von Zur Muhlen
    Sebastian Faby
    Fabio Capilli
    Christopher Schuppert
    Ramona Schmitt
    Philipp Ruile
    Dirk Westermann
    Christopher L. Schlett
    Fabian Bamberg
    Tobias Krauss
    Martin Soschynski
    The International Journal of Cardiovascular Imaging, 2024, 40 : 811 - 820
  • [7] Photon-counting CT-angiography in pre-TAVR aortic annulus assessment: effects of retrospective vs. prospective ECG-synchronization on prosthesis valve selection
    Hagar, Muhammad Taha
    Kluemper, Theresa
    Hein, Manuel
    von Zur Muhlen, Constantin
    Faby, Sebastian
    Capilli, Fabio
    Schuppert, Christopher
    Schmitt, Ramona
    Ruile, Philipp
    Westermann, Dirk
    Schlett, Christopher L.
    Bamberg, Fabian
    Krauss, Tobias
    Soschynski, Martin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (04): : 811 - 820
  • [8] Retrospectively ECG-gated helical vs. non-ECG-synchronized high-pitch CTA of the aortic root for TAVI planning
    Horehledova, Barbora
    Mihl, Casper
    Boswijk, Ellen
    Crombag, Genevieve A. J. C.
    Nijssen, Estelle C.
    Nelemans, Patty J.
    Veenstra, Leo F.
    Wildberger, Joachim E.
    Das, Marco
    PLOS ONE, 2020, 15 (05):
  • [9] Non-ECG-gated high-pitch CT angiography versus hybrid ECG-gated CT angiography for aorta using 512-slice CT: comparison of image quality and radiation dose
    Lee, Jimin
    Jeong, Yeon Joo
    Lee, Geewon
    Kim, Chang Won
    Kim, Jin You
    Lee, Nam Kyung
    Lee, Han Cheol
    Lee, Ji Won
    ACTA RADIOLOGICA, 2023, 64 (02) : 515 - 523
  • [10] Improved Pulmonary Artery Evaluation Using High-Pitch Photon-Counting CT Compared to High-Pitch Conventional or Routine-Pitch Conventional Dual-Energy CT
    Yalon, Mariana
    Hoodeshenas, Safa
    Chan, Alex
    Horst, Kelly K.
    Crum, Isaac
    Thorne, Jamison E.
    Lee, Yong S.
    Yu, Lifeng
    Mccollough, Cynthia H.
    Fletcher, Joel G.
    Rajiah, Prabhakar Shantha
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (06) : 897 - 905