Excimer laser coronary angioplasty combined with drug-coated balloon in the treatment of in-stent restenosis

被引:2
|
作者
He, Pan [1 ,2 ]
Chen, Haiwei [1 ]
Yang, Junjie [1 ]
Gao, Lei [1 ]
Guo, Jun [1 ]
Chen, Yundai [1 ]
Wang, Qi [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Cardiol, Med Ctr 6, 6 Fucheng Rd, Beijing 100048, Peoples R China
[2] Med Sch Chinese PLA, Beijing, Peoples R China
关键词
contrast injection technique; drug-eluting balloon; excimer laser coronary angioplasty; in-stent restenosis; optical coherence tomography; ELUTING BALLOON; IMPLANTATION; MECHANISMS; PATTERNS; OUTCOMES; BUBBLE;
D O I
10.1002/lsm.23794
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Objectives: The aim of this study is to investigate the safety and efficacy of excimer laser coronary angioplasty (ELCA) combined with drug-coated balloons (DCBs) in the treatment of in-stent restenosis (ISR), and to explore whether the contrast injection technique would improve the neointimal tissue ablation of ELCA. Methods: We studied patients diagnosed with ISR between January 2019 and October 2022 at two medical centers. These patients underwent DCB angioplasty guided by optical coherence tomography (OCT). Based on whether ELCA was performed before DCB treatment, patients were categorized into two groups: the ELCA + DCB group and the DCB group. All patients underwent clinical follow-up 1 year after the procedure. The primary endpoint was the 1-year rate of target lesion revascularization (TLR), which was defined as any repeat percutaneous intervention or bypass surgery on the target vessel conducted to address restenosis or other complications related to the target lesion. The secondary endpoints including immediate luminal gain (Delta MLA, defined as the difference in minimum lumen area before and after the intervention). Results: A total of 85 lesions in 75 patients were included. The mean age of the study population was 64.2 +/- 12.0 years, with 81.3% male. Baseline clinical characteristics were well-balanced, and procedural success was 100% in both groups. The ELCA + DCB group (n = 24) exhibited a greater Delta MLA compared to the DCB group (n = 61) (3.57 +/- 0.79 mm(2) vs. 2.50 +/- 1.06 mm(2), [95% confidence interval, CI: 0.57-1.69], p < 0.001), The reduction in 1-year TLR was more frequently observed in patients from the ELCA + DCB group compared to the DCB group (hazard ratio 0.33 [95% CI: 0.11-0.99]; log-rank p = 0.048). The exploratory analysis showed that ELCA with contrast infusion is associated with greater acute lumen gain compared to ELCA with saline infusion (p < 0.001). Conclusions: The combination of ELCA and DCB is a safe and effective treatment strategy for in-stent stenosis. Additionally, compared with saline injection, ELCA with contrast injection is associated with greater acute lumen gain. However, the optimal contrast agent concentration and long-term outcome of the contrast injection technique need confirmation through larger sample sizes and prospective studies.
引用
收藏
页码:474 / 484
页数:11
相关论文
共 50 条
  • [1] Cutting Balloon Combined with Drug-Coated Balloon Angioplasty for the Treatment of In-Stent Restenosis
    Zheng, You-Cheng
    Lee, Wei-Chieh
    Fang, Hsiu-Yu
    Chen, Chien-Jen
    Yang, Cheng-Hsu
    Wu, Chiung-Jen
    Fang, Chih-Yuan
    INTERNATIONAL HEART JOURNAL, 2021, 62 (06) : 1213 - 1220
  • [2] Excimer laser prior to drug-coated balloon treatment of in-stent restenosis
    Alfonso, Fernando
    Rivero, Fernando
    Cortese, Bernardo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 348 : 47 - 49
  • [3] Impact of in-stent tissue characteristics on excimer laser coronary angioplasty prior to drug-coated balloon treatment
    Ishihara, Takayuki
    Dohi, Tomoharu
    Nakamura, Daisuke
    Kikuchi, Atsushi
    Okamoto, Naotaka
    Mori, Naoki
    Iida, Osamu
    Tsujimura, Takuya
    Mizote, Isamu
    Higuchi, Yoshiharu
    Yamada, Takahisa
    Nishino, Masami
    Mano, Toshiaki
    Sakata, Yasushi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 339 : 28 - 32
  • [4] Differential Effects of Drug-Coated Balloon Angioplasty for In-Stent Restenosis
    Hong, Myeong-Ki
    Lee, Seung-Yul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (21) : 2679 - 2681
  • [5] Real-World Performance of Excimer Laser Ablation Combined with Drug-Coated Balloon Versus Drug-Coated Balloon for the Treatment of Femoropopliteal In-Stent Restenosis Disease
    Wang, Hui
    Wu, Sensen
    Pan, Dikang
    Ning, Yachan
    Sun, Chun
    Guo, Jianming
    Jiang, JinLan
    Gu, Yongquan
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [6] ADJUNCTIVE EFFECT OF EXCIMER LASER CORONARY ANGIOPLASTY FOR TREATMENT OF INSTENT RESTENOSIS WITH DRUG-COATED BALLOON
    Mastuda, Junji
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1374 - 1374
  • [7] Treatment of In-Stent Restenosis by Excimer Laser Coronary Atherectomy and Drug-Coated Balloon: Serial Assessment with Optical Coherence Tomography
    Miyazaki, Toru
    Ashikaga, Takashi
    Fukushima, Taku
    Hatano, Yu
    Sasaoka, Taro
    Kurihara, Ken
    Ono, Yuichi
    Shimizu, Shigeo
    Otomo, Kenichiro
    Hirao, Kenzo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2019,
  • [8] Treatment of in-stent coronary restenosis by excimer laser angioplasty
    Koster, R
    Hamm, CW
    Terres, W
    Koschyk, DH
    Reimers, J
    Kahler, J
    Meinertz, T
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (11): : 1424 - 1428
  • [9] Treatment of in-stent coronary restenosis with excimer laser angioplasty
    Liu, ML
    Chow, WH
    Kwok, OH
    Jim, MH
    Yip, A
    Fan, K
    Chan, E
    CHINESE MEDICAL JOURNAL, 2000, 113 (01) : 14 - 17
  • [10] Treatment of in-stent restenosis with excimer laser coronary angioplasty
    Karaca, I
    Ilkay, E
    Akbulut, M
    Yavuzkir, M
    JAPANESE HEART JOURNAL, 2003, 44 (02): : 179 - 186