Uniaxial-Oriented Chiral Perovskite for Flexible Full-Stokes Polarimeter

被引:2
|
作者
Chen, Quanlin [1 ]
Ding, Zijin [1 ]
Zhang, Li [1 ]
Wang, Di [1 ]
Geng, Cong [1 ]
Feng, Yanxing [2 ]
Zhang, Jia [1 ]
Ren, Miao [3 ]
Li, Saisai [1 ]
Qaid, Saif M. H. [4 ]
Jiang, Yuanzhi [1 ]
Yuan, Mingjian [1 ]
机构
[1] Nankai Univ, Coll Chem, Frontiers Sci Ctr New Organ Matter, State Key Lab Adv Chem Power Sources,Key Lab Adv E, Tianjin 300071, Peoples R China
[2] Henan Normal Univ, Sch Chem & Chem Engn, Xinxiang 453007, Peoples R China
[3] Guangxi Univ, Sch Phys Sci & Technol, State Key Lab Featured Met Mat & Life cycle Safety, Nanning 530004, Peoples R China
[4] King Saud Univ, Coll Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
基金
中国国家自然科学基金;
关键词
Blade coating; Flexible optoelectronics; Marangoni effect; Polarization detection; Uniaxially oriented; PHOTODETECTOR; DEPOSITION; GROWTH; FILMS;
D O I
10.1002/adma.202400493
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Full-Stokes polarization detection, with high integration and portability, offers an efficient path toward next-gen multi-information optoelectronic systems. Nevertheless, current techniques relying on optical filters create rigid and bulky configurations, limiting practicality. Here, a flexible, filter-less full-Stokes polarimeter featuring a uniaxial-oriented chiral perovskite film is first reported. It is found that, the strategic manipulation of the surfactant-mediated Marangoni effect during blade coating, is crucial for guiding an equilibrious mass transport to achieve oriented crystallization. Through this approach, the obtained uniaxial-oriented chiral perovskite films inherently possess anisotropy and chirality, and thereby with desired sensitivity to both linearly polarized light and circularly polarized light vectors. The uniaxial-oriented crystalline structure also improves photodetection, achieving a specific detectivity of 5.23 x 1013 Jones, surpassing non-oriented devices by 10x. The as-fabricated flexible polarimeters enable accurate capture of full-Stokes polarization without optical filters, exhibiting slight detection errors for the Stokes parameters: Delta S1 = 9.2%, Delta S2 = 8.6%, and Delta S3 = 6.5%, approaching the detection accuracy of optics-filter polarimeters. This proof of concept also demonstrates applications in matrix polarization imaging. A pioneering flexible full-Stokes polarimeter is developed and fabricated using a uniaxial-oriented chiral perovskite film. This achievement is a result of regulating fluid dynamics, specifically involving the control of the Marangoni effect during the blade coating process. The fabricated polarimeter demonstrates precise full-Stokes polarization detection, high-performance photoresponse, matrix polarization imaging capability, and superior mechanical durability. image
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Full-Stokes Polarimeter Based on Chiral Perovskites with Chirality and Large Optical Anisotropy
    Ma, Jiaqi
    Fang, Chen
    Liang, Lihan
    Wang, Haizhen
    Li, Dehui
    SMALL, 2021, 17 (47)
  • [2] Design and calibration for a Full-Stokes imaging polarimeter
    Montes Gonzalez, Ivan
    Bruce, Neil C.
    UNCONVENTIONAL OPTICAL IMAGING, 2018, 10677
  • [3] Snapshot compressive imaging full-Stokes polarimeter
    Xu, Zhilong
    Meng, Jianwen
    Zhao, Man
    Yang, Ting
    Wu, Dan
    Zhang, Rui
    Xie, Yingge
    Ren, Wenyi
    OPTICS COMMUNICATIONS, 2022, 509
  • [4] Optimum angles for a full-Stokes scanning polarimeter
    Hu, Qiang
    Qiu, Zhenwei
    Cui, Weihua
    Hong, Jin
    APPLIED OPTICS, 2019, 58 (16) : 4277 - 4282
  • [5] Chip-scale, full-Stokes polarimeter
    Lin, Zhongjin
    Rusch, Leslie
    Chen, Yuxuan
    Shi, Wei
    OPTICS EXPRESS, 2019, 27 (04) : 4867 - 4877
  • [6] Full-Stokes Polychromatic Polarimeter Design for Arago
    Pertenais, Martin
    Neiner, Coralie
    Petit, Pascal
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [7] Uniaxial-Oriented Perovskite Films with Controllable Orientation
    Li, Dongni
    Sun, Xiangyu
    Zhang, Yao
    Guan, Zhen
    Yue, Yansong
    Wang, Qingya
    Zhao, Lu
    Liu, Fangze
    Wei, Jing
    Li, Hongbo
    ADVANCED SCIENCE, 2024, 11 (19)
  • [8] Design of a Full-Stokes Polarimeter for VLT/X-shooter
    Snik, Frans
    van Harten, Gerard
    Navarro, Ramon
    Groot, Paul
    Kaper, Lex
    de Wijn, Alfred
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY IV, 2012, 8446
  • [9] A full-Stokes polarimeter for the GREGOR Fabry-Perot interferometer
    Balthasar, Horst
    Gonzalez, N. Bello
    Collados, M.
    Denker, C.
    Hofmann, A.
    Kneer, F.
    Puschmann, K. G.
    COSMIC MAGNETIC FIELDS: FROM PLANETS, TO STARS AND GALAXIES, 2009, (259): : 665 - +
  • [10] Method to calibrate a full-Stokes polarimeter based on variable retarders
    Montes-Gonzalez, Ivan
    Bruce, Neil C.
    Rodriguez-Herrera, Oscar G.
    Rodriguez Nunez, Omar
    APPLIED OPTICS, 2019, 58 (22) : 5952 - 5957