Nebuliser systems for drug delivery in cystic fibrosis

被引:1
|
作者
Stanford, Gemma [1 ]
Morrison, Lisa [2 ]
Brown, Catherine [3 ]
机构
[1] Guys & St Thomass NHS Fdn Trust, Royal Brompton Hosp, Dept Adult Cyst Fibrosis, London, England
[2] Southern Gen Hosp, West Scotland Adult CF Unit, Queen Elizabeth Univ Hosp, Glasgow, Lanark, Scotland
[3] West Midlands Adult Cyst Fibrosis Ctr, Birmingham, W Midlands, England
关键词
Anti-Bacterial Agents [therapeutic use; Cystic Fibrosis [drug therapy; Nebulizers and Vaporizers; Respiratory Aerosols and Droplets; Saline Solution; Hypertonic [therapeutic use; Tobramycin [therapeutic use; ADAPTIVE AEROSOL DELIVERY; QUALITY-OF-LIFE; LUNG DEPOSITION; TOBRAMYCIN INHALATION; DISEASE SEVERITY; ADHERENCE DATA; DORNASE ALPHA; AAD SYSTEM; CHILDREN; ADULTS;
D O I
10.1002/14651858.CD007639.pub3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Nebuliser systems are used to deliver medications to the lungs, to control the symptoms and the progression of lung disease in people with cystic fibrosis (CF). There are many different nebulised-medications prescribed for people with CF and there are many different types of nebuliser systems. Some of these nebulised medications are licenced for, and can be taken via only one type of nebuliser system; some are licensed for, and can be taken via more than one type of nebuliser system. This is an update to a previous systematic review. Objectives To assess the time efficiency, effectiveness, safety, cost and impact of use (e.g. burden of care, adherence, quality of life (QoL)) of different nebuliser systems, when used with different inhaled medications for people with CF. Search methods We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches, handsearching of relevant journals and abstract books containing conference proceedings. We searched the reference lists of each study for additional publications and approached the manufacturers of both nebuliser systems and nebulised medications for published and unpublished data. We also searched online trial registries. Date of the most recent search: 9 August 2023. Selection criteria Randomised controlled trials (RCTs) or quasi-RCTs comparing nebuliser systems, including conventional nebulisers, vibrating mesh technology (VMT) systems, adaptive aerosol delivery (AAD) systems and ultrasonic nebuliser systems. Data collection and analysis Two review authors independently assessed studies for inclusion. They also independently extracted data and assessed the risk of bias. A third review author assessed studies where agreement could not be reached. They assessed the certainty of the evidence using GRADE. Main results The search identified 216 studies with 33 of these (2270 participants) included in the review. These studies compared the delivery of tobramycin, colistin, dornase alfa, hypertonic saline and other solutions through the different nebuliser systems in children and adults with CF. This review demonstrates variability in the delivery of medication depending on the nebuliser system used. The certainty of the evidence ranged from low to very low. Some conventional nebuliser systems providing higher flows, higher respirable fractions, and smaller particles decrease treatment time, increase deposition (the amount of drug reaching the lung), and may be preferred by people with CF, as compared to other conventional nebuliser systems providing lower flows, lower respirable fractions and larger particles. Newer nebuliser systems using AAD, or VMT (or both) reduce treatment time compared to conventional systems. Deposition (as a percentage of priming dose) with AAD is greater than with conventional systems. VMT systems may give greater deposition than conventional systems when measuring sputum levels. The available data indicate that these newer systems are safe when used with an appropriate priming dose, which may be different to the priming dose used for conventional systems. There is an indication that adherence is maintained or improved and that individuals prefer AAD or VMT systems, but also that some nebuliser systems using VMT may be subject to increased system failures. There is limited, unclear evidence on the impact of different nebuliser systems on lung function and a lack of data on the impact of different nebuliser systems on our outcomes of quality of life (QoL), adverse effects, respiratory exacerbations and related implications, adherence, satisfaction, cost and device reliability. Authors' conclusions Newer technologies e.g. AAD and VMT have advantages over conventional systems in terms of treatment time, deposition as a percentage of priming dose, preference and adherence. Data are lacking for all varieties of medications which are used in CF care, including different inhaled antibiotics or hypertonic saline, with all delivery (nebuliser system) possibilities. Long-term RCTs are needed to evaluate different nebuliser systems to determine patient-focused outcomes (such as QoL and burden of care), safe and effective dosing levels of a wide variety of medications, clinical outcomes (such as hospitalisations and need for antibiotics), and an economic evaluation of their use. There are insufficient data to establish whether one nebuliser system is better than another overall. Clinicians should be aware of the variability in the performance of different nebuliser systems, compatibility with specific nebulised medication, and they must work with their patients to choose the best nebuliser system for each individual. This is likely to be an ongoing process as the needs and circumstances of each individual change over time.
引用
收藏
页数:151
相关论文
共 50 条
  • [1] Nebuliser systems for drug delivery in cystic fibrosis
    Daniels, Tracey
    Mills, Nicola
    Whitaker, Paul
    PAEDIATRIC RESPIRATORY REVIEWS, 2013, 14 (02) : 98 - 99
  • [2] Nebuliser systems for drug delivery in cystic fibrosis
    Daniels, Tracey
    Mills, Nicola
    Whitaker, Paul
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (04):
  • [3] Efficiency assessment of 15 nebuliser systems by the respirable drug delivery rate
    Fischer, Ralf
    Jukic, Filip
    Ledermueller, Rosina
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [4] Nebuliser hygiene in cystic fibrosis: evidence-based recommendations
    Bell, Jane
    Alexander, Lauren
    Carson, Jane
    Crossan, Amanda
    McCaughan, John
    Mills, Hazel
    O'Neill, Damian
    Moore, John E.
    Millar, B. Cherie
    BREATHE, 2020, 16 (02) : 1 - 18
  • [5] Fungal contamination of nebuliser devices used by people with cystic fibrosis
    Peckham, D.
    Williams, K.
    Wynne, S.
    Denton, M.
    Pollard, K.
    Barton, R.
    JOURNAL OF CYSTIC FIBROSIS, 2016, 15 (01) : 74 - 77
  • [6] Nanoparticles as Drug Delivery Vehicles for People with Cystic Fibrosis
    Hourihane, Eoin
    Hixon, Katherine R.
    BIOMIMETICS, 2024, 9 (09)
  • [7] Cystic fibrosis: Treatment with a supercomputer drug delivery model
    Martonen, TB
    Hwang, D
    Katz, I
    Yang, Y
    Guan, X
    ADVANCES IN ENGINEERING SOFTWARE, 1997, 28 (06) : 359 - 364
  • [8] Serum tobramycin levels following delivery of tobramycin (Tobi®) via eFlow® advanced nebuliser in children with cystic fibrosis
    Guy, E. L.
    Bosomworth, M.
    Denton, M.
    Conway, S. P.
    Brownlee, K. G.
    Lee, T. W. R.
    JOURNAL OF CYSTIC FIBROSIS, 2010, 9 (04) : 292 - 295
  • [9] Comparison of the HaloLite® adaptive aerosol delivery (AAD™) system with a high output nebuliser system in cystic fibrosis patients
    Marsden, RJ
    Conway, SP
    Dodd, ME
    Edenborough, FP
    Rigby, AS
    Taylor, CJ
    Weller, PH
    THORAX, 2002, 57
  • [10] Daily Observations of Nebuliser Use and Technique (DONUT) in children with cystic fibrosis
    Bos, Aukje C.
    Tiddens, Harm A. W. M.
    Minh, Kirby Tong
    Heeres, Inge
    Overweel-Uijterlinde, Joke L.
    Kok, Annelies E.
    Andrinopoulou, Eleni-Rosalina
    Janssens, Hettie M.
    JOURNAL OF CYSTIC FIBROSIS, 2016, 15 (05) : 645 - 651