Dual Fuzzy-Sugeno Method to Enhance Power Quality Performance using a Single-phase Dual UPQC-Dual PV Without DC-Link Capacitor

被引:3
|
作者
Amirullah, Amirullah [1 ]
Adiananda, Adiananda [2 ]
机构
[1] Univ Bhayangkara Surabaya, Dept Elect Engn, Surabaya 60231, Indonesia
[2] Univ Bhayangkara Surabaya, Surabaya, Indonesia
关键词
Dual-fuzzy Sugeno; dual-proportional-integral; power quality; single-phase; 2UPQC-2PV; total harmonics distortion; CONDITIONER; IUPQC;
D O I
10.23919/PCMP.2023.000107
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Unified power quality conditioner (UPQC) is a power electronics device consisting of a series active filter (Se-AF) and a shunt active filter (Sh-AF) connected in parallel through a DC-link circuit to overcome power quality problems, i.e., voltage sag, voltage swell, and non-linear (NL) load. The weakness of the UPQC is that it cannot function normally if the Se-AF and/or Sh-AF fail, and the devices are unable to transfer active power to the load in the event of an interrupt voltage at the source. This paper proposes a novel configuration of a dual UPQC supplied by a dual photovoltaic (PV), hereinafter referred to as 2UPQC-2PV, to improve the power quality performance of a single-phase 220 V/50 Hz distribution system. The 2UPQC-2PV configuration is proposed to anticipate the possible failure of both inverters in one of the UPQC circuits. The PV array replaces the DC-link capacitor to maintain its voltage connected to the DC-link of the UPQC constant while at the same time supplying active power to the load during an interruption voltage. The dual-fuzzy Sugeno (dual-FS) method is used to overcome the weakness of the dual-proportional-integral (dual-PI) control in determining the optimum parameters of proportional and integral constants. There are three disturbances simulated in each-of 2UPQC-2PV and 1UPQC-1PV using dual-FS and dual-PI, i.e., Case 1 (S-Sag-NL), Case 2 (S-Swell-NL), and Case 3 (S-Inter-NL). Each UPQC-PV combination using FS control is compared with PI control resulting in a total of six cases. The 2UPQC-2PV configuration with dual-PI and dual-FS controls, in the three fault cases, is able to produce higher voltage changes than the 1UPQC-1PV configuration. For the 2UPQC-2PV configuration in the three fault cases, Dual-FS control is able to produce lower THDs of load voltage and source current, than the dual-PI control, while meetings the limits of IEEE 519 Standard. In Case 3, the configuration of 2UPQC-2PV using the dual-FS method, is capable of delivering the active power of the load close to that in Case 1.
引用
收藏
页码:133 / 153
页数:21
相关论文
共 9 条
  • [1] A Maximum Power Point Tracking Technique for Single-Phase PV Systems with Reduced DC-Link Capacitor
    Yarlagadda, S. K.
    Shireen, Wajiha
    2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 2950 - +
  • [2] Simplified Power Estimation Feedforward to Reduce DC-Link Capacitance in Single-Phase Dual-Stage Full-Bridge Microinverter
    Vongkoon, Pokkrong
    Liutanakul, Pisit
    IEACON 2021: 2021 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE (IEACON), 2021, : 119 - 124
  • [3] Reduction in DC-Link Capacitor Current by Phase Shifting Method for a Dual Three-Phase Voltage Source Inverters Dual Permanent Magnet Synchronous Motors System
    Sahin, Deniz
    Dag, Bulent
    WORLD ELECTRIC VEHICLE JOURNAL, 2025, 16 (01):
  • [4] A modified indirect extraction method for a single-phase shunt active power filter with smaller DC-link capacitor size
    Fallah, Mehdi
    Modarresi, Javad
    Kojabadi, Hossein Madadi
    Chang, Liuchen
    Guerrero, Josep M.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 45
  • [5] A modified indirect extraction method for a single-phase shunt active power filter with smaller DC-link capacitor size
    Fallah, Mehdi
    Modarresi, Javad
    Madadi Kojabadi, Hossein
    Chang, Liuchen
    Guerrero, Josep M.
    Modarresi, Javad (j.modarresi@qiet.ac.ir), 1600, Elsevier Ltd (45):
  • [6] A Single-phase Grid-connected PV Converter with Minimal DC-link Capacitor and Low-frequency Ripple-free Maximum Power Point Tracking
    Shi, Yuxiang
    Liu, Liming
    Li, Hui
    Xue, Yaosuo
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 2385 - 2390
  • [7] Phase Current Measurement Method of Dual Inverter-Motor Drive System Using a Single DC Link Current Sensor
    Hwang, Seon-Ik
    Cho, Seong-Hyeon
    Jung, Jun-Hyung
    Kim, Jang-Mok
    ENERGIES, 2021, 14 (18)
  • [8] Single-phase Thirteen-level Dual-boost Inverter Based Shunt Active Power Filter Control Using Resonant and Fuzzy Logic Controllers
    Basha, Shaik Gouse
    Mani, Venkatesan
    Mopidevi, Subbarao
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2022, 8 (03): : 849 - 863
  • [9] Load Test Method Using Two Small-Capacity Power Supplies for High-Frequency Transformers in Single-Phase Dual Active Bridge Converters
    Orikawa, Koji
    Ogasawara, Satoshi
    2023 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2023, : 3288 - 3293