Identification of mathematical model of turbine generator unit in presence of uncertainty

被引:0
|
作者
Baliuta S.M. [1 ]
Chernenko P.O. [2 ]
Kuievda I.V. [1 ]
Kuevda V.P. [1 ]
机构
[1] National University of Food Technologies, Volodymyrska str, 68, Kyiv
[2] Institute of Electrodynamics National Academy of Sciences of Ukraine, pr. Peremohy, 56, Kyiv
来源
Technical Electrodynamics | 2021年 / 01期
关键词
automated control system; identification; turbine generator unit;
D O I
10.15407/TECHNED2021.01.032
中图分类号
学科分类号
摘要
An identification procedure of mathematical model of turbine generator unit in the presence of uncertainty is studied for using in the interconnected robust control automated system. The procedure is based on “worst-case” identification approach. The controlled object is modelled by the matrix transfer function with additive uncertainty. The identification consists of two stages: first is to identify transfer function with nominal parameters with the use of prediction error minimization algorithm, second to determine weight function in additive uncertainty model using finding the worst-case log-magnitude curve of uncertainties. Identification is performed in active way determining datasets for each control channel from individual experiments. A linear frequency-modulated signal is selected as the input test disturbance. A simulation model of the controlled object is constructed and the numerical experiment is conducted using the identification procedure. References 11, figures 7. © 2021. All rights reserved.
引用
收藏
页码:32 / 38
页数:6
相关论文
共 50 条
  • [1] On a Pathological Mathematical Model of Boiler-turbine-generator Unit
    Han Zhong-Xu
    Zhou Chuan-Xin
    Li Dan
    7TH INTERNATIONAL CONFERENCE ON SYSTEM SIMULATION AND SCIENTIFIC COMPUTING ASIA SIMULATION CONFERENCE 2008, VOLS 1-3, 2008, : 1104 - +
  • [2] Study on Simulation Mathematical Model of Supercritical Boiler-turbine-generator Unit
    Han Zhong-xu
    Feng Jian
    Wan Hui
    Zhou Chuan-xin
    Kao Zhi-qiang
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 43 - +
  • [3] The parameter estimation for a non-linear mathematical model of boiler-turbine-generator unit
    Han Zhong-xu
    Gao Chun-yu
    Li Dan
    ICIEA 2007: 2ND IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-4, PROCEEDINGS, 2007, : 1767 - +
  • [4] Simulation Study and Mathematical-Physical Analysis on a Model of Boiler-Turbine-Generator Unit
    Han, Zhongxu
    Li, Dan
    Zhou, Chuanxin
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 3182 - 3187
  • [5] IDENTIFICATION OF THE MATHEMATICAL MODEL OF A GAS TURBINE ENGINE TAKING INTO ACCOUNT THE UNCERTAINTY OF THE INITIAL DATA
    Baturin, Oleg
    Popov, Grigorii
    Nicolalde, Paul
    Korneeva, Anastasia
    PROCEEDINGS OF ASME 2021 GAS TURBINE INDIA CONFERENCE (GTINDIA2021), 2021,
  • [6] On Condenser Mathematical Model Method Introduction into Steam Turbine Unit Mathematical Model
    Shempelev, A.
    Iglin, P.
    Tatarinova, N.
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [7] Identification of Mathematical Model of Drying Unit
    Perevoshchikov, F. P.
    Vuong, N. V.
    Shabo, A. K.
    Shilin, A. A.
    INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND MODERN TECHNOLOGIES 2019 (MEMT2019), 2020, 795
  • [8] On-line Identification of Synchronous Generator Mathematical Model
    Miskovic, Mato
    Mirosevic, Marija
    Miskovic, Ivan
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [9] Mathematical modelling and simulation of wind turbine generator
    Ding, Yi-Tao
    International Journal of Mechatronics and Applied Mechanics, 2018, 2018 (04): : 166 - 169
  • [10] Study on the Establishment of the Steam-Turbine Generator Unit Shafting Entity Model
    Guo Wenwen
    LiJuan
    Jiao Shaohua
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2016, : 79 - 82