Patient-specific non-invasive estimation of the aortic blood pressure waveform by ultrasound and tonometry

被引:0
|
作者
Zhou, Shuran [1 ,2 ]
Xu, Kai [3 ]
Fang, Yi [3 ]
Alastruey, Jordi [4 ]
Vennin, Samuel [4 ]
Yang, Jun [5 ]
Wang, Junli [5 ]
Xu, Lisheng [1 ,6 ,7 ]
Wang, Xiaocheng [2 ]
Greenwald, Steve E. [8 ]
机构
[1] Northeastern Univ, Coll Med & Biol Informat Engn, Shenyang 110169, Peoples R China
[2] Air Force Med Univ, Aerosp Clin Med Ctr, Sch Aerosp Med, Xian 710032, Peoples R China
[3] Gen Hosp Northern Theater Command, Dept Cardiol, Shenyang 110840, Peoples R China
[4] St Thomas Hosp, Kings Coll London, Div Imaging Sci & Biomed Engn, London SE1 7EH, England
[5] China Med Univ, Hosp 1, Dept Cardiovasc Ultrasound, Shenyang 110122, Peoples R China
[6] Minist Educ, Engn Res Ctr Med Imaging & Intelligent Anal, Shenyang 110169, Peoples R China
[7] Neusoft Res Intelligent Healthcare Technol Co Ltd, Shenyang 110169, Peoples R China
[8] Queen Mary Univ London, Barts & London Sch Med & Dent, Blizard Inst, London E1 4NS, England
基金
中国国家自然科学基金;
关键词
Aortic blood pressure; Flow velocity; Diameter; Pulse wave velocity; Ultrasound; PULSE-WAVE; VELOCITY; VALIDATION; ARTERIES; SPEED; DERIVATION;
D O I
10.1016/j.cmpb.2024.108082
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Aortic blood pressure (ABP) is a more effective prognostic indicator of cardiovascular disease than peripheral blood pressure. A highly accurate algorithm for non-invasively deriving the ABP wave, based on ultrasonic measurement of aortic flow combined with peripheral pulse wave measurements, has been proposed elsewhere. However, it has remained at the proof-of-concept stage because it requires a priori knowledge of the ABP waveform to calculate aortic pulse wave velocity (PWV). The objective of this study is to transform this proof-of-concept algorithm into a clinically feasible technique. Methods: We used the Bramwell-Hill equation to non-invasively calculate aortic PWV which was then used to reconstruct the ABP waveform from non-invasively determined aortic blood flow velocity, aortic diameter, and radial pressure. The two aortic variables were acquired by an ultrasound system from 90 subjects, followed by recordings of radial pressure using a SphygmoCor device. The ABPs estimated by the new algorithm were compared with reference values obtained by cardiac catheterization (invasive validation, 8 subjects aged 62.3 +/- 12.7 years) and a SphygmoCor device (non-invasive validation, 82 subjects aged 45.0 +/- 17.8 years). Results: In the invasive comparison, there was good agreement between the estimated and directly measured pressures: the mean error in systolic blood pressure (SBP) was 1.4 +/- 0.8 mmHg; diastolic blood pressure (DBP), 0.9 +/- 0.8 mmHg; mean blood pressure (MBP), 1.8 +/- 1.2 mmHg and pulse pressure (PP), 1.4 +/- 1.1 mmHg. In the non-invasive comparison, the estimated and directly measured pressures also agreed well: the errors being: SBP, 2.0 +/- 1.4 mmHg; DBP, 0.8 +/- 0.1 mmHg; MBP, 0.1 +/- 0.1 mmHg and PP, 2.3 +/- 1.6 mmHg. The significance of the differences in mean errors between calculated and reference values for SBP, DBP, MBP and PP were assessed by paired t -tests. The agreement between the reference methods and those obtained by applying the new approach was also expressed by correlation and Bland-Altman plots. Conclusion: The new method proposed here can accurately estimate ABP, allowing this important variable to be obtained non-invasively, using standard, well validated measurement techniques. It thus has the potential to relocate ABP estimation from a research environment to more routine use in the cardiac clinic. Short Abstract: A highly accurate algorithm for non-invasively deriving the ABP wave has been proposed elsewhere. However, it has remained at the proof-of-concept stage because it requires a priori knowledge of the ABP waveform to calculate aortic pulse wave velocity (PWV). This study aims to transform this proof-of-concept algorithm into a clinically feasible technique. We used the Bramwell-Hill equation to non-invasively calculate aortic PWV which was then used to reconstruct the ABP waveform. The ABPs estimated by the new algorithm were compared with reference values obtained by cardiac catheterization or a SphygmoCor device. The results showed that there was good agreement between the estimated and directly measured pressures. The new method proposed can accurately estimate ABP, allowing this important variable to be obtained non -invasively, using standard, well validated measurement techniques. It thus has the potential to relocate ABP estimation from a research environment to more routine use in the cardiac clinic.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Patient-specific non-invasive estimation of pressure gradient across aortic coarctation using magnetic resonance imaging
    Shi, Yubing
    Valverde, Israel
    Lawford, Patricia V.
    Beerbaum, Philipp
    Hose, D. Rodney
    JOURNAL OF CARDIOLOGY, 2019, 73 (06) : 544 - 552
  • [2] 3.6: Non-Invasive, Mri-Based Estimation of Patient-Specific Aortic Blood Pressure Using One-Dimensional Blood Flow Modelling
    Jorge Mariscal Harana
    Arna van Engelen
    Torben Schneider
    Mateusz Florkow
    Peter Charlton
    Bram Ruijsink
    Hubrecht De Bliek
    Israel Valverde
    Marietta Carakida
    Kuberan Pushparajah
    Spencer Sherwin
    Rene Botnar
    Jordi Alastruey
    Artery Research, 2017, 20 (1) : 54 - 55
  • [3] Non-invasive method for the aortic blood pressure waveform estimation using the measured radial EBI
    Krivoshei, Andrei
    Lamp, Juergen
    Min, Mart
    Uuetoa, Tiina
    Uuetoa, Hasso
    Annus, Paul
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [4] A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry
    Sándor Földi
    Tamás Horváth
    Flóra Zieger
    Péter Sótonyi
    György Cserey
    Journal of Clinical Monitoring and Computing, 2018, 32 : 717 - 727
  • [5] A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry
    Foldi, Sandor
    Horvath, Tamas
    Zieger, Flora
    Sotonyi, Peter
    Cserey, Gyorgy
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (04) : 717 - 727
  • [6] A non-invasive, patient-specific method for estimating detrusor bladder pressure
    Heng, Chin Tiong
    Yeow, Siang Lin
    Lee, Heow Pueh
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2014, 2 (01): : 4 - 11
  • [7] Non-Invasive Patient-specific Acoustic Property Estimation for MR-guided Focused Ultrasound Surgery
    Vyas, Urvi
    Payne, Allison
    Todd, Nick
    Parker, Dennis L.
    Roemer, Robert B.
    Christensen, Douglas A.
    11TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1481 : 419 - 425
  • [8] Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
    Chemla, Denis
    Agnoletti, Davide
    Jozwiak, Mathieu
    Zhang, Yi
    Protogerou, Athanase D.
    Millasseau, Sandrine
    Blacher, Jacques
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (08):
  • [9] Non-invasive estimation of central aortic pressure from radial artery tonometry by neural networks
    Varanini, M
    Massoni, M
    Marraccini, P
    Kozákovà, M
    Djukic, G
    Bamoshmoosh, M
    Testa, R
    Vittone, F
    Palombo, C
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 501 - 504
  • [10] Electrical Bio-Impedance based non-invasive method for the central aortic blood pressure waveform estimation
    Krivoshei, Andrei
    Min, Mart
    Uuetoa, Hasso
    Lamp, Jurgen
    Annus, Paul
    2014 PROCEEDINGS OF THE 14TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC 2014), 2014, : 181 - 184