Research on Nonlinear Characteristics for Frequency Domain Dielectric Response of Transformer Oil-paper Insulation

被引:0
|
作者
Zhang M. [1 ]
Meng F. [1 ]
Liu J. [1 ]
Liu H. [2 ]
Jia H. [2 ]
Li L. [1 ]
机构
[1] Key Laboratory of Engineering Dielectrics and Its Application of Ministry of Education, Harbin University of Science and Technology, Heilongjiang Province, Harbin
[2] Electric Power Research Institute of State Grid Heilongjiang Electric Power Co., Ltd., Heilongjiang Province, Harbin
基金
中国国家自然科学基金;
关键词
conductivity; frequency domain dielectric response (FDS); nonlinear; oil-paper insulation;
D O I
10.13334/j.0258-8013.pcsee.212175
中图分类号
学科分类号
摘要
Frequency domain dielectric response (FDS) technology is an important method for nondestructive evaluation of transformer oil-paper insulation. The nonlinear change of dielectric properties of oil-paper insulation will affect the accuracy of evaluation, thus it is necessary to study the nonlinear FDS properties of oil-paper insulation. In this paper, several groups of oil-paper insulation samples with different aging and moisture content are prepared in the laboratory conditions. The nonlinear FDS test of oil-paper insulation under different test temperature is carried out. According to the test, when the moisture content of oil paper insulation is lower, the low-frequency dielectric response of oil-paper insulation is negatively correlated with voltage at low test temperature. With the increase of test temperature, the nonlinear changing region moves towards high frequency. The relationship between FDS variation and test excitation amplitude decreases. When the test temperature is high and the moisture content of oil-paper insulation is large, the low-frequency dielectric response of oil-paper insulation shows a new nonlinear law, which is positively correlated with voltage. Both relaxation activation energy and AC conductivity activation energy have a linear relationship with the moisture content in oil-impregnated pressboard. The test excitation amplitude affects the AC conductance activation energy more significantly. To eliminate the influence of test temperature on AC conductivity, the correction function is established to correct the low-frequency AC conductivity of oil-paper insulation at high temperature and high moisture content. Finally, combined with the calculation model of water molecular group mobility established in this paper, the influence of moisture content on the nonlinear change for frequency dielectric response of aging oil-paper insulation is quantitatively calculated, and the law is consistent with the experimental results. ©2023 Chin.Soc.for Elec.Eng.
引用
收藏
页码:831 / 842
页数:11
相关论文
共 22 条
  • [1] CHI Minghe, WANG Qian, LUO Qinglin, Influence of oil-paper insulation electric-dynamic parameters on calculation results of electric field at the end of converter transformer[J], Proceedings of the CSEE, 42, 5, pp. 1701-1712, (2022)
  • [2] WANG Jianyi, LIU Xueli, SUN Jiantao, Research progress and prospect of new aging characterization of oil-paper insulation[J], Proceedings of the CSEE, 41, 21, pp. 7517-7528, (2021)
  • [3] CHEIM L,, PLATTS D, PREVOST T, Furan analysis for liquid power transformers[J], IEEE Electrical Insulation Magazine, 28, 2, pp. 8-21, (2012)
  • [4] Jiefeng LIU, Tengyue SUN, Xianhao FAN, A modified simulation model for predicting the FDS of transformer oil-paper insulation under nonuniform aging [J], IEEE Transactions on Instrumentation and Measurement, 70, (2021)
  • [5] LIU Qingzhen, ZHANG Xiaoyan, CAI Jinding, Relaxation spectrum characteristic parameters extraction and aging diagnosis for oil-paper insulation [J], Electric Machines and Control, 24, 5, pp. 124-134, (2020)
  • [6] WU Guangning, XIA Guoqiang, SONG Zhenjie, Status assessment of aging condition of transformer oil-paper insulation based on time domain dielectric spectroscopy and wavelet analysis[J], High Voltage Engineering, 44, 1, pp. 226-233, (2018)
  • [7] DUTTA S, MISHRA D, HAQUE N, Influence of temperature on interfacial charge of power transformer insulation[J], IET Science,Measurement & Technology, 13, 7, pp. 1059-1067, (2019)
  • [8] CAI Jinding, LIN Xiaoning, Transformer oil-paper insulation diagnosis based on time domain dielectric spectral average relaxation factor[J], Electric Machines and Control, 23, 12, pp. 108-115, (2019)
  • [9] XIE Jiacheng, DONG Ming, YU Boning, Spectra extraction and quantitative analysis for all independent dielectric processes of oil-paper insulation in broad frequency band[J], Proceedings of the CSEE, 41, 5, pp. 1547-1556, (2021)