Robotic arm-assisted total hip arthroplasty via a minimally invasive anterolateral approach in the supine position improves the precision of cup placement in patients with developmental dysplasia of the hip

被引:3
|
作者
Tamaki, Yasuaki [1 ]
Goto, Tomohiro [1 ,2 ]
Wada, Keizo [1 ]
Omichi, Yasuyuki [1 ]
Hamada, Daisuke [1 ]
Sairyo, Koichi [1 ]
机构
[1] Tokushima Univ, Grad Sch, Inst Biomed Sci, Dept Orthoped, 3-18-15 Kuramoto, Tokushima, Tokushima 7708503, Japan
[2] Tokushima Univ, Dept Orthoped, Inst Hlth Biosci, 3-18-15 Kuramoto, Tokushima, Tokushima 7708503, Japan
关键词
ACETABULAR COMPONENT; DIRECT ANTERIOR; DISLOCATION; STEM; IMPLANTATION; REPLACEMENT; ORIENTATION; CHARNLEY; THA;
D O I
10.1016/j.jos.2023.01.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study evaluated the accuracy of the cup alignment angles and spatial cup positioning on computed tomography (CT) images in patients with osteoarthritis secondary to developmental dysplasia of the hip (DDH) who underwent total hip arthroplasty (THA) using a minimally invasive technique via an anterolateral approach in the supine position according to whether a robotic armassisted system or a CT-based navigation system was used. Methods: We reviewed 60 robotic arm-assisted (RA)-THA cases and 174 navigation-assisted (NA)-THA cases. After propensity score matching, there were 52 hips in each group. Postoperative cup alignment angles and position were assessed by superimposition of a three-dimensional cup template onto the actual implanted cup using postoperative CT images with pelvic coordinates matching the preoperative planning. Results: The mean absolute error of the inclination angle and the anteversion angle between the preoperative planning and the postoperative measurement was significantly smaller in the RA-THA group (inclination, 1.1 degrees +/- 0.9; anteversion, 1.3 degrees +/- 1.0) than in the NA-THA group (inclination, 2.2 degrees +/- 1.5; anteversion, 3.3 degrees +/- 2.5). For acetabular cup positioning, the mean discrepancy between the preoperative planning and the postoperative measurement was 1.3 +/- 1.3 mm on the transverse axis, 2.0 +/- 2.0 mm on the longitudinal axis, and 1.3 +/- 1.7 mm on the sagittal axis in the RA-THA group and 1.6 +/- 1.4 mm, 2.6 +/- 2.3 mm, and 1.8 +/- 1.3 mm, respectively, in the NA-THA group. High precision of cup positioning was observed in both groups with no statistically significant difference. Conclusion: Robotic arm-assisted THA using a minimally invasive technique via an anterolateral approach in the supine position allows accurate cup placement in patients with DDH. (c) 2023 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 50 条
  • [1] Minimally invasive total hip replacement via the anterolateral approach in the supine position
    G. Pflüger
    S. Junk-Jantsch
    V. Schöll
    International Orthopaedics, 2007, 31 : 7 - 11
  • [2] Minimally invasive total hip replacement via the anterolateral approach in the supine position
    Pflueger, G.
    Junk-Jantsch, S.
    Schoell, V.
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (Suppl 1) : S7 - S11
  • [3] Robotic-assisted total hip arthroplasty in patients with developmental dysplasia of the hip
    Zhang, Shuai
    Ma, Mingyang
    Kong, Xiangpeng
    Zhou, Yonggang
    Chen, Jiying
    Chai, Wei
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (05) : 1189 - 1199
  • [4] Robotic-assisted total hip arthroplasty in patients with developmental dysplasia of the hip
    Shuai Zhang
    Mingyang Ma
    Xiangpeng Kong
    Yonggang Zhou
    Jiying Chen
    Wei Chai
    International Orthopaedics, 2024, 48 : 1189 - 1199
  • [5] Comparison of the accuracy of the cup position and orientation in total hip arthroplasty for osteoarthritis secondary to developmental dysplasia of the hip between the Mako robotic arm-assisted system and computed tomography-based navigation
    Ando, Wataru
    Takao, Masaki
    Hamada, Hidetoshi
    Uemura, Keisuke
    Sugano, Nobuhiko
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1719 - 1725
  • [6] Comparison of the accuracy of the cup position and orientation in total hip arthroplasty for osteoarthritis secondary to developmental dysplasia of the hip between the Mako robotic arm-assisted system and computed tomography-based navigation
    Wataru Ando
    Masaki Takao
    Hidetoshi Hamada
    Keisuke Uemura
    Nobuhiko Sugano
    International Orthopaedics, 2021, 45 : 1719 - 1725
  • [7] Modified anterolateral approach in minimally invasive total hip arthroplasty
    Tsai, Shang-Wen
    Chen, Cheng-Fong
    Wu, Po-Kuei
    Chen, Tain-Hsiung
    Liu, Chien-Lin
    Chen, Wei-Ming
    HIP INTERNATIONAL, 2015, 25 (03) : 245 - 250
  • [8] Total hip arthroplasty using the anterolateral minimally invasive approach
    Bostan, Bora
    Sen, Cengiz
    Gunes, Taner
    Erdem, Mehmet
    Aytekin, Kuersat
    Erkorkmazi, Uenal
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (06) : 464 - 471
  • [9] Precision of acetabular cup placement in robotic integrated total hip arthroplasty
    Elson, Leah
    Dounchis, Jon
    Illgen, Richard
    Marchand, Robert C.
    Padgett, Douglas E.
    Bragdon, Charles R.
    Malchau, Henrik
    HIP INTERNATIONAL, 2015, 25 (06) : 531 - 536
  • [10] Robotic-Assisted Total Hip Arthroplasty in Patients Who Have Developmental Hip Dysplasia
    Hepinstall, Matthew
    Mota, Frank
    Muthusamy, Nishanth
    Naylor, Brandon
    Salem, Hytham S.
    Coden, Gloria
    Mont, Michael A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 39