Experimental study on impedance characteristics of 10 kV magnetic biased superconducting current limiter

被引:0
|
作者
Wei D. [1 ]
Wang F. [1 ]
Zhu J. [2 ]
Liu Y. [1 ]
Liu C. [2 ]
Liu J. [1 ]
机构
[1] Electric Power Research Institute of State Grid Liaoning Electric Power Supply Co.,Ltd., Shenyang
[2] China Electric Power Research Institute, Beijing
关键词
current limiting rate; impedance characteristics; magnetic biased; mathematical model; superconducting current limiter;
D O I
10.16081/j.epae.202205031
中图分类号
学科分类号
摘要
The mathematical model of current limiting process for 10 kV grid is established in combination with the system operating conditions. The current limiting mechanism in different stages is analyzed and the changing trend of impedance characteristics of magnetic biased superconducting current limiter is obtained. The impedance characteristics operation test circuit of 10 kV magnetic biased superconducting current limiter is constructed, based on which, the current waveforms under different current limiting conditions are measured, and the equivalent equation and the variation curve of impedance characteristics of magnetic biased superconducting current limiter are obtained. The study results show that, in stable operation stage, the equivalent impedance of the current limiter is 0.13 Ω, the limiting rate of the current peak under the setting Condition 1 and 2 are 13.1 % and 8.98 % respectively in initial current limiting stage;in steady current limiting stage, the equivalent impedance of the current limiter is 1.667 Ω, and the limiting rate of the current peak under the setting Condition 1 and 2 are 16.23% and 14.13% respectively. The mathematical equation of the impedance characteristics of the current limiter in initial current limiting stage is given. © 2022 Electric Power Automation Equipment Press. All rights reserved.
引用
收藏
页码:114 / 119
页数:5
相关论文
共 20 条
  • [1] pp. 323-334, (2006)
  • [2] Lei CHEN, Zhe LI, DENG Changhong, Et al., Effects of a flux-coupling type superconducting fault current limiter on the surge current caused by closed-loop operation in a 10 kV distribution network[J], International Journal of Electrical Power & Energy Systems, 69, pp. 160-166, (2015)
  • [3] LIN Xin, WANG Feiming, FENG Kai, Et al., Study on dielectric strength recovery mechanism of high voltage SF<sub>6</sub> circuit breaker [J], Proceedings of the CSEE, 37, 20, pp. 6118-6125, (2017)
  • [4] WANG Feiming, ZHAO Yisong, SHI Kejian, Et al., Simulation analysis of arc characteristics on breaking zero zone in high voltage SF<sub>6</sub> circuit breaker [J], High Voltage Engineering, 45, 5, pp. 1420-1428, (2019)
  • [5] WANG Feiming, LIN Xin, XU Jianyuan, Extinction characteristics of non-equilibrium plasma arc in high-voltage SF<sub>6</sub> circuit breaker [J], High Voltage Engineering, 40, 10, pp. 3073-3084, (2014)
  • [6] Xin LIN, Feiming WANG, Jianyuan XU, Et al., Study on the mathematical model of dielectric recovery characteristics in high voltage SF<sub>6</sub> circuit breaker[J], Plasma Science and Technology, 18, 3, pp. 223-229, (2016)
  • [7] ZHANG Zhifeng, QIU Qingquan, ZHANG Guomin, Et al., Modeling and optimal design of 220 kV split reactance type superconducting fault current limiter[J], High Voltage Engineering, 43, 4, pp. 1129-1136, (2017)
  • [8] WANG Changqi, LI Bin, XIN Ying, Et al., Review on research and application of high-temperature superconducting DC fault current limiter [J], Automation of Electric Power Systems, 45, 18, pp. 179-191, (2021)
  • [9] ZHENG Jianchao, Current status and application prospect of fault current limiters[J], Proceedings of the CSEE, 34, 29, pp. 5140-5148, (2014)
  • [10] PENG Yongquan, LIN Xiangning, CHEN Le, Et al., Research on global cooperative configuration of superconducting fault current limiter considering life cycle cost[J], Proceedings of the CSEE, 39, 21, pp. 6275-6288, (2019)