Restoration of magnetohydrodynamic-corrupted 12-lead electrocardiogram to enhance cardiac monitoring during magnetic resonance imaging

被引:0
|
作者
Mahmud, Sakib [1 ]
Chowdhury, Muhammad E. H. [1 ]
Chowdhury, Moajjem Hossain [2 ]
Alqahtani, Abdulrahman [3 ,4 ]
Bin Mahbub, Zaid [5 ]
Bensaali, Faycal [1 ]
Kiranyaz, Serkan [1 ]
机构
[1] Qatar Univ, Dept Elect Engn, Doha, Qatar
[2] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Bangi 43600, Malaysia
[3] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci Al Kharj, Dept Biomed Technol, Al Kharj 11942, Saudi Arabia
[4] Majmaah Univ, Coll Appl Med Sci, Dept Med Equipment Technol, Majmaah City 11952, Saudi Arabia
[5] North South Univ, Dept Phys & Math, Dhaka, Bangladesh
关键词
Magnetohydrodynamics corrupted; electrocardiogram restoration; Magnetic resonance imaging; Cardiac monitoring; Unpaired signal restoration; One dimensional-Segmentation; QRS COMPLEX; HEART-RATE; ECG; MRI; ALGORITHM; SUPPRESSION; EXTRACTION; POLARITY; SAFETY;
D O I
10.1016/j.engappai.2024.108483
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Magnetohydrodynamic (MHD) effect on the bloodstream, induced by the static magnetic field of Magnetic Resonance Imaging (MRI) devices, distorts Electrocardiogram (ECG) components, and poses challenges to cardiac gating and monitoring during MRI examinations. Restoring ECG components from MHD-induced artifacts has always been a challenge, primarily due to the influence of numerous device-induced and physiological variables and the absence of paired ground truth clean ECG for validation. In this research, at first, we employ unpaired restoration of MHD-corrupted 12-lead ECG signals using one dimensional (1D) Cycle Generative Adversarial Networks (CycleGANs) for channel and patient orientation-specific restoration. Subsequently, a 1Dsegmentation-based comprehensive restoration scheme is proposed based on the phase 1 outputs to simultaneously restore 12-channel ECG signals, irrespective of internal and external factors affecting ECG. By employing the proposed Magnetohydrodynamic Generative Adversarial Network ( MHDGAN) and MHD-to-ECG Network (MHD2ECGNet) for unpaired and comprehensive restoration, we achieved an overall spectral correlation improvement of 92.56% and 77.64% , respectively. In R-peak detection, MHDGAN demonstrated an overall precision, recall, and F1-score of 98.14% , 94.12% , and 96.01% , respectively. The extracted heart rate (HR) and heart rate variability (HRV) from the restored waveforms closely match the ground truth, as confirmed through quantitative and qualitative assessments. The proposed framework has proven effective in restoring MHDcorrupted ECG waveforms, even in the absence of paired ground truth labels and amidst compounding distortions from multiple sources.
引用
收藏
页数:27
相关论文
共 32 条
  • [1] Evaluation of 12-lead electrocardiogram at 0.55T for improved cardiac monitoring in magnetic resonance imaging
    Kolandaivelu, Aravindan
    Bruce, Christopher G.
    Seemann, Felicia
    Yildirim, Dursun Korel
    Campbell-Washburn, Adrienne E.
    Lederman, Robert J.
    Herzka, Daniel A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (01)
  • [2] Left ventricular mass by 12-lead electrocardiogram in healthy subjects:: comparison to cardiac magnetic resonance imaging
    Carlsson, MB
    Trägårdh, E
    Engblom, H
    Hedström, E
    Wagner, G
    Pahlm, O
    Arheden, H
    JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (01) : 67 - 72
  • [3] Can the Extent of Late Gadolinium Enhancement on Cardiac Magnetic Resonance Be Predicted by the 12-Lead Electrocardiogram?
    Bao, Chen
    Madias, Christopher
    Studley, Rachael
    Bokhari, Nadia
    Quintana, Erick
    Maron, Barry
    Maron, Martin S.
    Maron, Martin
    Rowin, Ethan J.
    CIRCULATION, 2022, 146
  • [4] Mismatch between localization of Q waves in 12-lead electrocardiogram and localization of myocardial infarction at magnetic resonance imaging
    Rovai, D.
    Di Bella, G.
    Rossi, G.
    Strata, E.
    Lombardi, M.
    L'abbate, A.
    Pingitore, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 840 - 840
  • [5] The relationship between, electrical axis by 12-lead electrocardiogram and anatomical axis of the heart by cardiac magnetic resonance in healthy subjects
    Engblom, H
    Foster, JE
    Martin, TN
    Groenning, B
    Pahlm, O
    Dargie, HJ
    Wagner, GS
    Arheden, H
    AMERICAN HEART JOURNAL, 2005, 150 (03) : 507 - 512
  • [6] Diagnostic value of the 12-lead electrocardiogram during conventional and biventricular pacing for cardiac resynchronization
    Barold, S. Serge
    Giudici, Michael C.
    Herweg, Bengt
    Curtis, Anne B.
    CARDIOLOGY CLINICS, 2006, 24 (03) : 471 - +
  • [7] Fragmented QRS Complexes on 12-Lead ECG: A Marker of Cardiac Sarcoidosis as Detected by Gadolinium Cardiac Magnetic Resonance Imaging
    Homsi, Mohamed
    Alsayed, Lamaan
    Safadi, Bilal
    Mahenthiran, Jo
    Das, Mithilesh K.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2009, 14 (04) : 319 - 326
  • [8] Suspected cardiac syncope in elderly patients: Use of the 12-lead electrocardiogram to select patients for Holter monitoring
    Manchanda, S
    Ehsanullah, M
    GERONTOLOGY, 2001, 47 (04) : 195 - 197
  • [9] ST-Segment deviation analysis of the admission 12-lead electrocardiogram as an aid to early diagnosis of acute myocardial infarction with a cardiac magnetic resonance imaging gold standard
    Martin, Thomas N.
    Groenning, Bjoern A.
    Murray, Heather M.
    Steedman, Tracey
    Foster, John E.
    Elliot, Alex T.
    Dargie, Henry J.
    Selvester, Ronald H.
    Pahlm, Olle
    Wagner, Galen S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (11) : 1021 - 1028
  • [10] 3T cardiac imaging with on-line 12-lead ECG monitoring
    Mikayel Dabaghyan
    Shelley H Zhang
    Jay Ward
    Raymond Y Kwong
    William G Stevenson
    Ronald D Watkins
    Zion T Tse
    Ehud J Schmidt
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)