Pericardial Closure With Expanded Polytetrafluoroethylene Patch in Left Ventricular Assist Device Surgery

被引:1
|
作者
Meinert, Etienne F. R. C. [1 ]
Kremer, Jamila [1 ]
Tochtermann, Ursula [1 ]
Sommer, Wiebke [1 ]
Warnecke, Gregor [1 ]
Karck, Matthias [1 ]
Meyer, Anna L. [1 ]
机构
[1] Heidelberg Univ Hosp, Dept Cardiac Surg, Neuenheimer Feld 420, D-69120 Heidelberg, Germany
关键词
left ventricular assist device; mechanical circulatory support; expanded polytetrafluoroethylene patch; mediastinitis; INTERMACS PROFILES; INFECTIONS; DEFINITION; MEMBRANE; IMPACT;
D O I
10.1097/MAT.0000000000002126
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To reduce adhesions after left ventricular assist device (LVAD) implantation, pericardial closure using an expanded polytetrafluoroethylene (ePTFE) patch has been suggested. However, as foreign material, ePTFE patches could increase the risk of infectious complications. In this single-center retrospective study, we investigated outcomes of pericardial closure using an ePTFE patch in LVAD implantation. We included all patients who underwent LVAD implantation at our center between 2011 and 2020 (n = 166). Primary endpoint was development of mediastinitis at any point of time between LVAD implantation and heart transplantation (HTx) or death. Secondary endpoint was overall survival. Preoperative and postoperative clinical data were collected to ensure comparability between the groups. We included 166 patients with LVAD. A total of 116 patients (70%) underwent pericardial closure using an ePTFE patch. There were significant differences between the groups in treatment setting, previous cardiac surgery, Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level, development of driveline infection, and HTx. Patients with an ePTFE patch developed mediastinitis more frequently (16%) than patients without ePTFE patch (4%) (p = 0.039). A significant difference in overall survival between the groups could not be confirmed (p = 0.29). The use of PTFE patches for pericardial closure in LVAD implantation was associated with a higher incidence of mediastinitis, but not with a difference in overall survival.
引用
收藏
页码:371 / 376
页数:6
相关论文
共 50 条
  • [1] Outcomes of expanded polytetrafluoroethylene pericardial membrane implantation in left ventricular assist device explantation and heart transplantation
    An, Kevin R.
    Christakis, Nicole
    Jegatheeswaran, Anusha
    Cusimano, Robert J.
    Rao, Vivek
    Badiwala, Mitesh
    Yau, Terrence M.
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 4316 - 4323
  • [2] USE OF EXPANDED POLYTETRAFLUOROETHYLENE PERICARDIAL SUBSTITUTE WITH VENTRICULAR ASSIST DEVICES
    HOLMAN, WL
    BOURGE, RC
    ZORN, GL
    BRANTLEY, LH
    KIRKLIN, JK
    ANNALS OF THORACIC SURGERY, 1993, 55 (01): : 181 - 183
  • [3] Infective endocarditis of bovine pericardial patch in the aortic position in a patient with left ventricular assist device
    Nakae, Masaro
    Yoshioka, Daisuke
    Toda, Koichi
    Miyagawa, Shigeru
    Yoshikawa, Yasushi
    Hata, Hiroki
    Kainuma, Satoshi
    Kawamura, Takuji
    Kawamura, Ai
    Sawa, Yoshiki
    JOURNAL OF ARTIFICIAL ORGANS, 2019, 22 (04) : 345 - 347
  • [4] Infective endocarditis of bovine pericardial patch in the aortic position in a patient with left ventricular assist device
    Masaro Nakae
    Daisuke Yoshioka
    Koichi Toda
    Shigeru Miyagawa
    Yasushi Yoshikawa
    Hiroki Hata
    Satoshi Kainuma
    Takuji Kawamura
    Ai Kawamura
    Yoshiki Sawa
    Journal of Artificial Organs, 2019, 22 : 345 - 347
  • [5] Modified pericardial closure technique in patients with ventricular assist device
    Vitali, E
    Russo, C
    Tiziano, C
    Lanfranconi, M
    Bruschi, G
    ANNALS OF THORACIC SURGERY, 2000, 69 (04): : 1278 - 1279
  • [6] Patch closure of the aortic anulus in a recipient of a ventricular assist device
    Savage, EB
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (02): : 403 - 403
  • [7] Patch closure of the aortic anulus in a recipient of a ventricular assist device
    Stringham, JC
    Bull, DA
    Karwande, SV
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (06): : 1293 - 1294
  • [8] Noncardiac surgery in patients with a left ventricular assist device
    Puri, Archana
    Tobin, Raj
    Bhattacharjee, Shameek
    Kapoor, Mukul Chandra
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2020, 28 (01): : 15 - 21
  • [9] Surgical Correction of Left Ventricular Assist Device Outflow Graft Obstruction Caused by a Wrapped Expanded Polytetrafluoroethylene Graft: A Case Report
    Kim, Sung Min
    Park, Ilkun
    Oh, Siwon
    Seo, Hyo Won
    Jeong, Ga Hee
    Lee, Jun Ho
    Chung, Su Ryeun
    Sung, Kiick
    Kim, Wook Sung
    Cho, Yang Hyun
    JOURNAL OF CHEST SURGERY, 2024, 57 (04): : 413 - 417
  • [10] Right ventricular failure after thoracotomy left ventricular assist device; the role of pericardial restraint
    Worku, Berhane
    Naka, Yoshifumi
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (10) : 3082 - 3083