Analysis of the impact of temperature on the spectral shift in ultraviolet hyperspectral imaging spectrometers

被引:1
|
作者
Pan, Guotao [1 ,2 ]
Li, Bo [1 ]
Gu, Guochao [1 ]
Yu, Xiangyang [1 ]
Li, Hanshuang [1 ]
Wang, Xiaoxu [1 ]
Li, Zhanfeng [1 ]
Yang, Xiaohu [1 ]
Zhu, Junqing [1 ]
Cao, Diansheng [1 ,3 ]
Li, Bingqiang [1 ]
Ma, Qingjun [1 ]
Wu, Heng [1 ]
He, Limin [1 ]
Lin, Guanyu [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Ocean Univ China, Fac Informat Sci & Engn, Qingdao 266100, Peoples R China
基金
中国国家自然科学基金;
关键词
DESIGN;
D O I
10.1364/OE.517945
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The imaging spectrometer's high performance in practical applications may be compromised by environmental factors, particularly temperature variations, posing a challenge to its stability. Temperature fluctuations can induce spectral shift, directly impacting the accuracy of spectral measurements, subsequently influencing the precision of radiometric measurements. To address this issue, this study investigates a dual -channel UV imaging spectrometer. This instrument boasts a wavelength calibration accuracy of 0.01 nm. This paper conducts an in-depth analysis of the various mechanisms through which temperature changes influence the spectral line offset in the imaging spectrometer, integrating actual orbital temperature data to discuss the instrument's temperature load settings. The impact of temperature on spectral shift is examined using finite element analysis and optical design software. Estimations of spectral shift were made based on temperature variations. Simulation results indicated that the maximum deviation of spectral shift is estimated at 0.018 nm under a temperature condition of 16 +/- 1 degrees C. Under a more controlled orbital temperature condition (16 +/- 0.3 degrees C), the maximum deviation of spectral shift decreased to 0.01 nm. Experimental data revealed that at 16 +/- 1 degrees C, the maximum deviation of spectral shift did not exceed 0.01 nm. This effectively corroborates our theoretical analysis. The relationship between temperature and spectral shift offers a crucial theoretical foundation for calibrating spectral measurements and managing the thermal conditions of the instrument. (c) 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:11774 / 11793
页数:20
相关论文
共 50 条
  • [1] Uncertainty analysis of in-flight spectral calibration for hyperspectral imaging spectrometers
    Zhao, Huijie
    Geng, Ruonan
    Jia, Guorui
    Wang, Daming
    IMAGE AND SIGNAL PROCESSING FOR REMOTE SENSING XXIII, 2017, 10427
  • [2] Temperature and Emissivity Inversion Accuracy of Spectral Parameter Changes and Noise of Hyperspectral Thermal Infrared Imaging Spectrometers
    Shao, Honglan
    Liu, Chengyu
    Li, Chunlai
    Wang, Jianyu
    Xie, Feng
    SENSORS, 2020, 20 (07)
  • [3] SPECTRAL MAPPING WITH IMAGING SPECTROMETERS
    RUBIN, TD
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1993, 59 (02): : 215 - 221
  • [4] Innovative manufacturing and test technologies for imaging hyperspectral spectrometers
    Cobb, Joshua M.
    Comstock, Lovell E.
    Dewa, Paul G.
    Dunn, Mike M.
    Flint, Scott D.
    ALGORITHMS AND TECHNOLOGIES FOR MULTISPECTRAL, HYPERSPECTRAL, AND ULTRASPECTRAL IMAGERY XII PTS 1 AND 2, 2006, 6233
  • [5] Comparison of hyperspectral imaging and spectrometers for prediction of cheeses composition
    Medeiros, Maria Lucimar da Silva
    deCarvalho, Leila Moreira
    Madruga, Marta Suely
    Rodriguez-Pulido, Francisco J.
    Heredia, Francisco J.
    Barbin, Douglas Fernandes
    FOOD RESEARCH INTERNATIONAL, 2024, 183
  • [6] ON THE ULTRAVIOLET SPECTRAL SHIFT PHENOMENON OF CHLOROQUINE
    OWOYALE, JA
    ELMARAKBY, Z
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1982, 12 (2-3) : 265 - 269
  • [7] Spectral and spatial uniformity in pushbroom imaging spectrometers
    Mouroulis, P
    IMAGING SPECTROMETRY V, 1999, 3753 : 133 - 141
  • [8] Characterization and Calibration of Compact Array Spectrometers in the Ultraviolet Spectral Region
    Shindo, Francois
    Woolliams, Emma
    Scott, Barry
    Harris, Subrena
    RADIATION PROCESSES IN THE ATMOSPHERE AND OCEAN (IRS2012), 2013, 1531 : 809 - 812
  • [9] Hyperspectral imaging of polymer banknotes for building and analysis of spectral library
    Lim, Hoong-Ta
    Murukeshan, Vadakke Matham
    OPTICS AND LASERS IN ENGINEERING, 2017, 98 : 168 - 175
  • [10] Hyperspectral Cathodoluminescence Imaging and Analysis Extending from Ultraviolet to Near Infrared
    MacRae, C. M.
    Wilson, N. C.
    Torpy, A.
    Davidson, C. J.
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (06) : 1239 - 1245