Study of pulsation pressures in the stages of an electric submersible pump at shut-off under various speeds of operation

被引:0
|
作者
Dhanasekaran A. [1 ]
Kumaraswamy S. [2 ]
机构
[1] Department of Mechanical Engineering, Chennai Institute of Technology, Chennai
[2] Department of Mechanical Engineering, IIT Madras, Chennai
关键词
Diffuser casing; Electric submersible pump; Harmonics; Pressure pulsation; Shut-off; Stage; Variable frequency drive;
D O I
10.2174/2212797613666200220141119
中图分类号
学科分类号
摘要
Background: Electric Submersible Pumps (ESPs) are widely used in agricultural fields, petroleum, and various other industries. These pumps are mostly driven at a constant speed since an A.C. motor is normally used as the drive. However, ESPs can also be operated at various speeds by employing a Variable Frequency Drive (VFD). Several patents have been published in ESP. Normally these pumps are started with the discharge valve at its closed position in order to control the starting current. When the ESP runs at its shut-off position, it will develop a higher head and an increase in fluctuating pressure. In order to evaluate the effects of pressure fluctuation, its characteristics must be investigated. Objective: Experimentally investigate the characteristics of pressure pulsation which are generated at each stage of a multistage ESP during shut-off condition at various speeds. Methods: An ESP with five stages was selected for conducting experiments. A VFD was used for operating the ESP at five speed settings from 80 to 120 % of its rated speed. Piezoresistive transducer was placed at the delivery side of the pump to acquire the signals of unsteady pressure. The pump was operated at closed valve condition at each speed, and unsteady pressure signals due to pressure pulsation were captured. Results: Obtained results have indicated the presence of fundamental frequency pertaining to vane passing frequency and harmonics of higher frequencies. Conclusion: Study of pressure fluctuations at shut-off will help to analyze the failures of ESP due to vibration which occur when the pump runs at closed valve position for a prolonged length of time and stability of these pumps at lower flow rates. © 2020Bentham Science Publishers.
引用
收藏
页码:171 / 183
页数:12
相关论文
共 13 条
  • [1] Pressure pulsation in stages of electric submersible pump at shut-off under various speeds
    DHANASEKARAN Arumugam
    KUMARASWAMY Sivasailam
    排灌机械工程学报, 2020, (07) : 649 - 657
  • [2] Study of Stage-wise Pressure Pulsation in an Electric Submersible Pump under Variable Frequency Operation at Shut-off Condition
    Dhanasekaran A.
    Kumaraswamy S.
    Journal of The Institution of Engineers (India): Series C, 2019, 100 (01) : 213 - 220
  • [3] INVESTIGATION OF PRESSURE PULSATION IN THE STAGES OF AN ELECTRIC SUBMERSIBLE PUMP AT BEST EFFICIENCY POINT UNDER VARIOUS SPEEDS
    Arumugam, Dhanasekaran
    Sivasailam, Kumaraswamy
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 3B, 2019,
  • [4] THEORETICAL AND EXPERIMENTAL STUDY OF TRANSIENT FLOWS DUE TO PUMP SHUT-OFF
    Kayikci, Nuri Seckin
    Guney, M. Sukru
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2009, 24 (02): : 359 - 368
  • [5] Numerical analysis of pressure pulsation in vertical submersible axial flow pump device under bidirectional operation
    Yang, Fan
    Chang, Pengcheng
    Li, Chao
    Shen, Qiangru
    Qian, Jun
    Li, Jindong
    AIP ADVANCES, 2022, 12 (02)
  • [6] Transient characteristics of double-suction centrifugal pump during starting period under shut-off condition
    Liu, Zhuqing
    Zhu, Qiang
    Yang, Wei
    Li, Yaojun
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2015, 46 (10): : 44 - 48
  • [7] Pressure fluctuation study in the stages of a multistage pump at best efficiency points under various operating speeds
    Arumugam, Dhanasekaran
    Sivasailam, Kumaraswamy
    JOURNAL OF ENGINEERING RESEARCH, 2022, 10 (2B): : 227 - 247
  • [8] Wave tracking method of hydraulic transients in pipe systems with pump shut-off under simultaneous closing of spherical valves
    Zhang, Zh.
    RENEWABLE ENERGY, 2019, 132 : 157 - 166
  • [9] Case Study - Improvements to Cementing Operation and Installation of Cement Packer and Inflatable Cement Retainer for Water Shut-Off
    Tan, R.Q.
    Nazim, N.I.
    Sidek, S.
    Yahaya, F.
    Yusof, R.
    Offshore Technology Conference Asia, OTCA 2024, 2024,
  • [10] Numerical and experimental study of shut-off rod assembly of a typical Indian research reactor under multi-support seismic excitation
    Kiran, A. Ravi
    Agrawal, M. K.
    Sinha, S. K.
    NUCLEAR ENGINEERING AND DESIGN, 2025, 432