Grid-connected/islanded control and output voltage harmonic suppression strategy for onboard power supply converters

被引:0
|
作者
Wang Y. [1 ]
Wen Y. [2 ]
Deng J. [3 ]
Peng Y. [1 ]
Lü Y. [1 ]
Qian Z. [1 ]
机构
[1] CRRC Zhuzhou Institute Co., Ltd., Zhuzhou
[2] School of Traffic & Transportation Engineering, Central South University, Changsha
[3] Shanghai CRRC Hange Marine & Offshore Engineering Co., Ltd., Shanghai
关键词
Control mode switching; Grid-connected/islanded control; Harmonic suppression; Onboard power supply converter; Reduced order generalized integrator; Seamless transfer;
D O I
10.16081/j.epae.202105001
中图分类号
学科分类号
摘要
Firstly, the current-voltage control mode switching method according to grid-connected/islanded status of onboard power supply converters is proposed, which realizes the fast response of output voltage under grid-islanded condition and the controlled transfer of interactive power with onshore AC grid under grid-connected condition. Secondly, the amplitude & frequency regulation based presynchronization control and the voltage and current double closed-loop control share one proportional-integral regulator, which gua-rantees the smooth transition of the integral quantity when control mode switching and realizes the seamless transfer of grid-connected/islanded control. Thirdly, the method of multiple ROGIs(Reduced Order Genera-lized Integrators) in parallel is introduced to suppress the voltage unbalance as well as 5th and 7th harmonics, and the control parameters of ROGI are designed directly in discrete domain to avoid the controller performance deviation caused by digitalization. Finally, the experimental platform for power supply converter of onboard DC-grid electric propulsion system is constructed to verify the correctness and effectiveness of the proposed control method. © 2021, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:161 / 168
页数:7
相关论文
共 19 条
  • [1] XU Longtang, DONG Xiaoni, Study on technology of shipboard common DC bus hybrid-electric propulsion system, Fishery Modernization, 44, 3, pp. 70-76, (2017)
  • [2] FOTIS D K, GEORGE J T, JOHN P., Onboard DC grid emp-loying smart grid technology:challenges, state of the art and future prospects, IET Electrical Systems in Transportation, 1, pp. 1-11, (2015)
  • [3] GUERRERO J M, BLAABJERG F, ZHELEV T, Et al., Distri-buted generation:toward a new energy paradiam, IEEE Industrial Electronics Magazine, 4, 1, pp. 52-64, (2010)
  • [4] PIAGI P., Microgrid:architectures and control, pp. 18-28, (2014)
  • [5] LI Junjie, Zhenyu LU, WU Zaijun, Et al., Adaptive switching stra-tegy of AC/DC hybrid microgrid operating mode based on power electronic transformer, Electric Power Automation Equipment, 40, 10, pp. 126-131, (2020)
  • [6] VASQUEZ J C, GUERRERO J M., Adaptive droop control app-lied to voltage-source inverters operating in grid-connected and islanded modes, IEEE Transactions on Industrial Elec-tronics, 56, 10, pp. 4088-4096, (2009)
  • [7] SHI Rongliang, ZHANG Xing, XU Haizhen, Et al., Seamless swit-ching control strategy for microgrid operation modes based on virtual synchronous generator, Automation of Electric Po-wer Systems, 40, 10, pp. 16-23, (2016)
  • [8] YUAN Zhichang, WEI Yingdong, LIU Wenhua, Et al., Connec-ting and islanding univeral control strategy for VSC of AC distribution grids, Electric Power Automation Equipment, 40, 2, pp. 1-7, (2020)
  • [9] ZHANG Xueyan, MA Weiming, FU Lijun, Et al., Parallel control strategy of inverter and diesel generator based on mode-switching method, Transactions of China Electrotechnical Society, 32, 18, pp. 220-229, (2017)
  • [10] GUO Li, FU Xiaopeng, LI Xialin, Et al., Coordinated control of battery storage and diesel generators in isolated AC micro-grid system, Proceedings of the CSEE, 32, 25, pp. 70-78, (2012)