Asymmetrical voltage fault ride-through of wind turbine with DFIG using DVR

被引:0
|
作者
Ling Y. [1 ]
Dou Z. [2 ]
机构
[1] Department of Electrical Engineering, Shanxi Datong University, Datong
[2] Electric Power Research Institute, State Grid Shanghai Municipal Electric Power Company, Shanghai
关键词
Asymmetrical voltage fault; Doubly-Fed Induction Generator(DFIG); Dynamic Voltage Restorer(DVR); Fault ride-through; Wind power generation;
D O I
10.16081/j.issn.1006-6047.2019.02.010
中图分类号
学科分类号
摘要
Based on the characteristics that DVR(Dynamic Voltage Restorer) can restore voltage in a short time, the capability of DVR to assist DFIG(Doubly-Fed Induction Generator) wind turbines for the improvement of asymmetrical voltage fault ride-through is investigated. For DFIG wind turbines, the topology and compensation strategy of DVR are selected. The DVR control method based on proportional-resonant controller is analyzed and a single-loop voltage feedback control strategy is proposed. The simulation experiments are performed with PSCAD/EMTDC. Results show that DFIG wind turbines can successfully ride through asymmetrical voltage faults under DVR protection and its improved transient behaviors. © 2019, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:65 / 70and77
页数:7012
相关论文
共 21 条
  • [1] Guan H., Zhao H., Chi Y., Et al., Requirement for LVRT capability of wind turbine generator in power system, Power System Technology, 31, 7, pp. 78-82, (2007)
  • [2] Ling Y., Cai X., Wang N., Rotor current transient analysis of DFIG-based wind turbines during symmetrical voltage faults, Energy Conversion and Management, 76, 1, pp. 910-917, (2013)
  • [3] Yu L., Chen G., Song X., Et al., A low voltage ride-through of strategy for doubly fed induction generator, Transactions of China Electrotechnical Society, 25, 9, pp. 170-175, (2010)
  • [4] Xiang D., Ran L., Tavner P.J., Et al., Control of a doubly fed induction generator in a wind turbine during grid fault ride-through, IEEE Transactions on Energy Conversion, 21, 3, pp. 652-662, (2006)
  • [5] Zhang D., Wei Y., Ma L., Et al., Sliding-mode control for grid-side converters of DFIG-based wind-power generation system under unbalanced grid voltage conditions, Transactions of China Electrotechnical Society, 30, 10, pp. 266-275, (2015)
  • [6] Nian H., Song Y., Zhou P., Et al., Improved direct power control of a wind turbine driven doubly fed induction generator during transient grid voltage unbalance, IEEE Tran-sactions on Energy Conversion, 26, 3, pp. 976-986, (2011)
  • [7] Rahimi M., Pamiani M., Transient performance improvement of wind turbines with doubly fed induction generators using nonlinear control strategy, IEEE Transactions on Energy Conversion, 25, 2, pp. 514-525, (2010)
  • [8] Ling Y., Cai X., Wang N., Combination of stator crowbar and DC-link discharge resistor for Fault Ride-Through(FRT) of DFIG, Electric Power, 46, 12, pp. 90-94, (2013)
  • [9] Ling Y., Cai X., Fault ride-through of DFIG wind turbine with rotor series resistor, Electric Power Automation Equipment, 34, 8, pp. 25-30, (2014)
  • [10] Ma W., Application of Crowbar circuit in grid fault riding through for doubly-fed induction wind power generation system, Electric Power Automation Equipment, 31, 7, pp. 127-130, (2011)