Capacitance probe for water holdup measurement in crude oil-water flows

被引:0
|
作者
Zheng X. [1 ]
Yang B. [1 ]
Bai B. [1 ]
机构
[1] State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an
来源
Measurement: Sensors | 2020年 / 10-12卷
关键词
Capacitance probe; Crude oil-water flow; Formed oil film; Water holdup;
D O I
10.1016/j.measen.2020.100028
中图分类号
学科分类号
摘要
Water holdup in crude oil-water flows is a crucial parameter to identify flow patterns or monitor the flow process in oil production. It has been increasingly important to accurately predict water holdup. Due to the simple structure and robust performance, capacitance probes have been widely used in experimental research and industrial application. In this paper, we proposed a water holdup measurement device based on a capacitance probe for crude oil-water flows. The measurement principle lies in the fact that the output capacitance is proportional to the part of the probe immersed in water. It was found that when inserted into crude oil, the surface of the probes will absorb hydrocarbons and form an oil film covering the probes. The formed oil film will reduce the sensitivity of the output capacitance to the water layer height. The thicker the film the lower the sensitivity. We examined the parameters that affect the thickness of the formed oil film and found that the thickness is mainly dependent on temperature and water holdup. The higher the temperature the thinner the formed oil film. The reason is that an increase of temperature leads to a decrease of viscosity. In addition, as the temperature approached about 50 ​°C, the thickness is nearly unchanged. As for the water holdup, at low temperatures the effect is considerable. At relatively high temperatures, the effect is minor and can be neglected. The experimental results showed that the capacitance probes have the highest sensitivity at about 50 ​°C. We designed and manufactured a prototype of the measurement device. The probes were inserted with heating wires to heat the crude oil near the probes and the current was controlled by an integrated circuit to maintain the temperature at about 50 ​°C. The field test showed that the natural gas entrained in the production fluids caused the device to under-predict the water holdup. After gas-liquid separation, the prediction errors were within ±6%. © 2020 The Authors
引用
收藏
相关论文
共 50 条
  • [1] Measurement of Water Holdup in Oil-Water Two-phase Flows Using Coplanar Waveguide
    Wei, Yong
    Yu, Houquan
    Chen, Jiefu
    PROCEEDINGS OF THE 2019 IEEE TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2019,
  • [2] Design of a Conductance and Capacitance Combination Sensor for water holdup measurement in oil-water two-phase flow
    Wu, Hao
    Tan, Chao
    Dong, Xiaoxiao
    Dong, Feng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 46 : 218 - 229
  • [3] Water holdup measurement of oil-water two-phase flow with low velocity using a coaxial capacitance sensor
    Chen, X.
    Han, Y. F.
    Ren, Y. Y.
    Zhang, H. X.
    Zhang, H.
    Jin, N. D.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 81 : 244 - 255
  • [4] Comparison Between 180°and 360° Double Helix Capacitance Sensors for Measuring Water Holdup of Horizontal Oil-Water Stratified Flows
    Jiang, Bin
    Tang, Ziyan
    Dai, Runsong
    Wang, Ziqu
    Bai, Landi
    Jin, Ningde
    IEEE SENSORS JOURNAL, 2023, 23 (06) : 5490 - 5500
  • [5] Measurement of Water Holdup in Oil-Water Two-Phase Flows Using Coplanar Microstrip Transmission Lines Sensor
    Wei, Yong
    Yu, Houquan
    Chen, Qiang
    Liu, Guoquan
    Chen, Jiefu
    IEEE SENSORS JOURNAL, 2019, 19 (23) : 11289 - 11300
  • [6] Measurement of Water Holdup in Vertical Upward Oil-Water Two-Phase Flow Pipes Using a Helical Capacitance Sensor
    Dai, Runsong
    Jin, Ningde
    Hao, Qingyang
    Ren, Weikai
    Zhai, Lusheng
    SENSORS, 2022, 22 (02)
  • [7] Area-alterable liquid electrode capacitance sensor for water holdup measurement in oil-water two-phase flow
    Yang, Yang
    Hu, Haihang
    Wang, Kai
    Wang, Shuai
    Liu, Ming
    Zhang, Chao
    Wang, Dong
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2021, 16 (05)
  • [8] Water holdup measurement of oil-water two-phase flow based on CPW
    Wei, Yong (7034669@qq.com), 1600, Science Press (38):
  • [9] Liquid holdup measurement in horizontal oil-water two-phase flow by using concave capacitance sensor
    Zhao An
    Jin Ningde
    Zhai Lusheng
    Gao Zhongke
    MEASUREMENT, 2014, 49 : 153 - 163
  • [10] Measurement of Water Holdup in Oil-in-Water Flows Using Three-Channel Conductance Probe With Center Body
    Wei, Jidong
    Jin, Ningde
    Lian, Enyang
    Wang, Dayang
    Han, Yunfeng
    Zhai, Lusheng
    IEEE SENSORS JOURNAL, 2018, 18 (07) : 2845 - 2852