Impact of abdominal compression on heart and stomach motion for stereotactic arrhythmia radioablation

被引:0
|
作者
Cecchi, Daniel David [1 ,2 ]
Ploquin, Nicolas Paul [1 ,2 ,3 ]
Faruqi, Salman [4 ,5 ]
Morrison, Hali [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Phys & Astron, 1331 29 St NW, Calgary, AB T2N 4N2, Canada
[2] Tom Baker Canc Clin, Dept Med Phys, Calgary, AB, Canada
[3] Univ Calgary, Dept Oncol, Div Med Phys, Calgary, AB, Canada
[4] Tom Baker Canc Clin, Dept Radiat Oncol, Calgary, AB, Canada
[5] Univ Calgary, Dept Oncol, Div Radiat Oncol, Calgary, AB, Canada
来源
关键词
immobilization; stereotactic radiotherapy; ventricular radioablation; TUMOR MOTION; RADIATION; ABLATION; RADIOTHERAPY; MANAGEMENT; LUNG;
D O I
10.1002/acm2.14346
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of abdominal compression (AC) as a respiratory motion management method for the heart and stomach during stereotactic arrhythmia radioablation (STAR). Methods: 4D computed tomography (4DCT) scans of patients imaged with AC or without AC (free-breathing: FB) were obtained from ventricular-tachycardia (VT) (n = 3), lung cancer (n = 18), and liver cancer (n = 18) patients. Patients treated for VT were imaged both FB and with AC. Lung and liver patients were imaged once with FB or with AC, respectively. The heart, left ventricle (LV), LV components (LVCs), and stomach were contoured on each phase of the 4DCTs. Centre of mass (COM) translations in the left/right (LR), ant/post (AP), and sup/inf (SI) directions were measured for each structure. Minimum distances between LVCs and the stomach over the respiratory cycle were also measured on each 4DCT phase. Mann-Whitney U-tests were performed between AC and FB datasets with a significance of alpha = 0.05. Results: No statistical difference (all p values were >0.05) was found in COM translations between FB and AC patient datasets for all contoured cardiac structures. A reduction in COM translation with AC relative to FB was patient, direction, and structure specific for the three VT patients. A significant decrease in the AP range of motion of the stomach was observed under AC compared to FB. No statistical difference was found between minimum distances to the stomach and LVCs between FB and AC. Conclusions: AC was not a consistent motion management method for STAR, nor does not uniformly affect the separation distance between LVCs and the stomach. If AC is employed in future STAR protocols, the motion of the target volume and its relative distance to the stomach should be compared on two 4DCTs: one while the patient is FB and one under AC.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] IMPACT OF ABDOMINAL COMPRESSION ON HEART AND STOMACH RESPIRATORY MOTION FOR STEREOTACTIC ARRHYTHMIA RADIOABLATION
    Cecchi, Daniel
    Morrison, Hali
    Ploquin, Nicolas
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S122 - S122
  • [2] Impact of compression on heart motion for stereotactic arrhythmia radioablation
    Cecchi, Daniel
    Morrison, Hali
    Ploquin, Nicolas
    MEDICAL PHYSICS, 2022, 49 (08) : 5648 - 5649
  • [3] Does Abdominal Compression Change the Direction of the Heart's Respiratory Motion in Stereotactic Arrhythmia Radioablation (STAR)?
    Marshall, J.
    Bergman, A. M.
    Deyell, M.
    Karan, T.
    Schellenberg, D.
    Thomas, S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7718 - 7719
  • [4] THE IMPACT OF ABDOMINAL COMPRESSION ON INTERNAL TARGET VOLUMES FOR PATIENTS UNDERGOING STEREOTACTIC ARRHYTHMIA RADIOABLATION FOR VENTRICULAR TACHYCARDIA
    Gerard, Ian J.
    Bernier, Martin
    Hijal, Tarek
    Kopek, Neil
    Pater, Piotr
    Stroian, Gabriela
    Joanne, Alfieri
    RADIOTHERAPY AND ONCOLOGY, 2022, 174 : S73 - S74
  • [5] Analysis of target motion in STereotactic Arrhythmia Radioablation for atrial fibrillation
    Di Guglielmo, F. C.
    Sanfrancesco, G.
    De Pascali, C.
    Gregucci, F.
    Surgo, A.
    Carbonara, R.
    Ciliberti, M. P.
    Caliandro, M.
    Paulicelli, E.
    Romanazzo, I.
    Di Monaco, A.
    Grimaldi, M.
    Bonaparte, I.
    Fiorentino, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2053 - S2054
  • [6] Stereotactic arrhythmia radioablation: A novel therapy for cardiac arrhythmia
    Wang, Songyun
    Luo, Hao
    Mao, Tianlong
    Xiang, Chunrong
    Hu, Haoyuan
    Zhao, Jiahui
    Wang, Xinqi
    Wang, Jiale
    Liu, Huafen
    Yu, Lilei
    Jiang, Hong
    HEART RHYTHM, 2023, 20 (09) : 1327 - 1336
  • [7] Stereotactic arrhythmia radioablation in recurrent ventricular tachyarrhythmias
    Cybulska, Magdalena
    Sajdok, Mateusz
    Bednarek, Jacek
    Miszczyk, Marcin
    Jadczyk, Tomasz
    Kurzelowski, Radoslaw
    Gardas, Rafal
    Drzewiecka, Anna
    Jarosinski, Grzegorz
    Zub, Kamil
    Latusek, Tomasz
    Wojakowski, Wojciech
    Blamek, Slawomir
    Golba, Krzysztof S.
    KARDIOLOGIA POLSKA, 2022, 80 (03) : 367 - 369
  • [8] Stereotactic arrhythmia radioablation: competitor or adjunct to catheter ablation?
    Kovacs, Boldizsar
    Mayinger, Michael
    Andratschke, Nicolaus
    Saguner, Ardan M.
    EUROPEAN HEART JOURNAL, 2022, 43 (35) : 3279 - 3281
  • [9] Precision requirements in stereotactic arrhythmia radioablation for ventricular tachycardia
    Fast, Martin F.
    Lydiard, Suzanne
    Boda-Heggemann, Judit
    Tanadini-Lang, Stephanie
    Muren, Ludvig P.
    Clark, Catharine H.
    Blanck, Oliver
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [10] Interobserver variability in target definition for stereotactic arrhythmia radioablation
    van der Ree, Martijn H.
    Cuculich, Phillip S.
    van Herk, Marcel
    Hugo, Geoffrey D.
    Balt, Jippe C.
    Bates, Matthew
    Ho, Gordon
    Pruvot, Etienne
    Herrera-Siklody, Claudia
    Hoeksema, Wiert F.
    Lee, Justin
    Lloyd, Michael S.
    Kemme, Michiel J. B.
    Sacher, Frederic
    Tixier, Romain
    Verhoeff, Joost J. C.
    Balgobind, Brian V.
    Robinson, Clifford G.
    Rasch, Coen R. N.
    Postema, Pieter G.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10