Profile of the Effectiveness Factor under Optimal Operating Conditions for the Conversion of Ortho-Xylene to Phthalic Anhydride in a Fixed-Bed Tubular Reactor

被引:0
|
作者
Carrasco-Venegas, Luis Americo [1 ]
Vasquez-Alvarez, Elsa [2 ]
Gonzalez-Fernandez, Jose Vulfrano [3 ]
Castaneda-Perez, Luz Genara [4 ]
Medina-Collana, Juan Taumaturgo [5 ]
Palomino-Hernandez, Guido [6 ]
Martinez-Hilario, Daril Giovanni [7 ]
Trujillo-Perez, Salvador Apolinar [1 ]
机构
[1] Univ Nacl Callao, Ctr Invest Bioenergia, Callao 07011, Peru
[2] Univ Sao Paulo, Dept Engn Minas & Petr, Escola Politecn, BR-05508030 Sao Paulo, Brazil
[3] Tecnol Nacl Mexico, Inst Tecnol San Luis Potosi, San Luis Potosi 78436, Mexico
[4] Univ Nacl Federico Villareal, Fac Ciencias Nat & Matemat, Lima 15001, Peru
[5] Univ Nacl Callao, Fac Ingn Quim, Ctr Invest Ingn Proc Tratamiento Aguas, Callao 07011, Peru
[6] Univ Nacl San Cristobal Huamanga, Fac Ingn Quim & Met, Ayacucho 05001, Peru
[7] Univ Nacl Callao, Fac Ingn Quim, Callao 07011, Peru
关键词
mass balance; energy balances; effectiveness factor; phthalic anhydride; DOE; optimization; O-XYLENE; CATALYTIC REACTOR; PARTIAL OXIDATION; KINETICS; V2O5/TIO2; MODEL; STATE;
D O I
10.3390/chemengineering8020035
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The objective of this research is to find the effectiveness factor of the catalyst particles for the most favorable conditions of the phthalic anhydride production in a fixed bed reactor, with the aim of achieving the highest rate of phthalic anhydride production compared to other secondary products and analyzing the areas of lower effectiveness for the modification of the reactor design. Initially, the material and the energy balances in the catalytic bed are solved to obtain the concentration and temperature profiles based on the radius and length of the reactor, using polymath software(Polymath (R) v6.2 Software Minitab 19 Matlab 2019) with the data from literature. Once the profiles reproducibility was verified using the initial data (inlet temperature, pressure in the reactor, reactor wall temperature, reactor radius and mass flow rate) the experimental design 35 carry out, which generates 243 "experiments", whose response variable (phthalic anhydride concentration) was obtained using Matlab. Subsequently, the variables were analyzed using the Minitab 18 (R) that, through the response surface analysis method, allowed us to obtain the optimal values of the tested variables. Then, Subsequently, material and energy balances coupled with Fourier and Fick's laws, along with the effectiveness factor equation, were applied, resulting in the generation of 9 coupled differential equations. Upon implementing the finite difference method, this yielded 90 nonlinear algebraic equations, which were solved using the Polymath software. A total of 78 particles were preselected based on their radial and axial positions to determine the effectiveness factor profile, with values ranging from 0.83 to near unity. The lower values correspond to the points with higher temperature, as evidenced by the calculations performed.
引用
收藏
页数:24
相关论文
共 12 条
  • [1] INFLUENCE OF THE INLET TEMPERATURE ON THE PERFORMANCE OF A FIXED-BED REACTOR FOR OXIDATION OF ORTHO-XYLENE INTO PHTHALIC-ANHYDRIDE
    NIKOLOV, VA
    ANASTASOV, AI
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (05) : 1291 - 1298
  • [2] OPTIMIZATION OF FIXED-BED CATALYTIC-OXIDATION OF ORTHO-XYLENE TO PHTHALIC-ANHYDRIDE
    OPREA, S
    VITAN, E
    DUMITRIU, E
    VITAN, F
    REVISTA DE CHIMIE, 1980, 31 (01): : 24 - 29
  • [3] A NEW APPROACH TO THE OXIDATION OF ORTHO-XYLENE INTO PHTHALIC-ANHYDRIDE IN A FIXED-BED OF VANADIUM TITANIUM CATALYST
    NIKOLOV, V
    ANASTASOV, A
    ELENKOV, D
    GANEV, G
    DIMITROV, N
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1988, 24 (03) : 157 - 162
  • [4] Optimal policies of operation of a fixed-bed reactor for oxidation of o-xylene into phthalic anhydride
    Anastasov, AI
    Nikolov, VA
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1998, 37 (08) : 3424 - 3433
  • [5] CATALYTIC VAPOR-PHASE OXIDATION OF ORTHO-XYLENE IN A FIXED-BED REACTOR
    SRIVASTAVA, KP
    DUTTA, R
    JAIN, IK
    INDIAN JOURNAL OF TECHNOLOGY, 1982, 20 (04): : 155 - 160
  • [6] OXIDATION OF ORTHO-XYLENE INTO PHTHALIC-ANHYDRIDE IN A REACTOR WITH 2 FIXED-BEDS OF VANADIUM-TITANIA CATALYST
    NIKOLOV, V
    ANASTASOV, A
    ELENKOV, D
    GANEV, G
    DIMITROV, N
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1989, 25 (03) : 127 - 131
  • [7] PREDICTION OF PACKED-BED CATALYTIC REACTOR PERFORMANCE FOR A COMPLEX-REACTION (OXIDATION OF ORTHO-XYLENE TO PHTHALIC-ANHYDRIDE)
    CHANDRASEKHARAN, K
    CALDERBANK, PH
    CHEMICAL ENGINEERING SCIENCE, 1979, 34 (11) : 1323 - 1331
  • [8] Analysis of the Effectiveness Factor in a Fixed-Bed Tubular Reactor System: Catalytic Dehydrogenation of Cyclohexanol
    Carrasco-Venegas, Luis Americo
    Gonzalez-Fernandez, Jose Vulfrano
    Castaneda-Perez, Luz Genara
    Medina-Collana, Juan Taumaturgo
    Palomino-Hernandez, Guido
    Martinez-Hilario, Daril Giovanni
    Trujillo-Perez, Salvador Apolinar
    CATALYSTS, 2023, 13 (03)
  • [9] The Reactor Size Influence on the Optimal Operating Setpoint Choice for a Fixed-Bed Multi-Tubular Catalytic Reactor
    Muscalu, Constantin
    Maria, Gheorghe
    Dinculescu, Daniel
    REVISTA DE CHIMIE, 2018, 69 (08): : 2012 - 2018
  • [10] Effect of uneven cooling medium temperature profiles on the conversion of reactive flow in a catalytic fixed bed reactor for the partial oxidation of ortho-xylene
    Fouad, M.M.K.
    Sabry, A.S.
    El Rifaie, M.A.
    El Ahwany, A.H.
    Modelling, Measurement and Control C, 1994, 45 (01): : 49 - 64