Detection of acute pulmonary embolism using native repeated magnetic resonance imaging acquisitions under free-breathing and without respiratory or cardiac gating. A diagnostic accuracy study

被引:1
|
作者
Medson, Koshiar [1 ,2 ,3 ,10 ]
Paris, Roberto Vargas [1 ,3 ]
Fyrdahl, Alexander [4 ,9 ]
Wiklund, Peder [5 ]
Nyren, Sven [3 ,4 ]
Westerlund, Eli [6 ,7 ]
Lindholm, Peter [1 ,8 ]
机构
[1] Karolinska Inst, Dept Physiol & Pharmacol, SE-17177 Stockholm, Sweden
[2] Brigham & Womens Hosp, Dept Radiol, Div Chest Imaging, Boston, MA USA
[3] Karolinska Univ Hosp, Dept Imaging & Physiol, SE-17176 Stockholm, Sweden
[4] Karolinska Inst, Dept Mol Med & Surg, SE-18288 Stockholm, Sweden
[5] Reg Halland, Dept Radiol, Halland, Sweden
[6] Karolinska Inst, Dept Clin Sci, SE-18288 Stockholm, Sweden
[7] Danderyd Hosp, Stockholm, Sweden
[8] Univ Calif San Diego, Dept Emergency Med, San Diego, CA USA
[9] Karolinska Univ Hosp, Dept Clin Physiol, Solna, Sweden
[10] Karolinska Univ Hosp, ME Radiol, B5 11, SE-17176 Stockholm, Sweden
关键词
Venous thromboembolism; Pulmonary embolism; Computed tomography angiography; Magnetic resonance imaging; MR; ANGIOGRAPHY; RISK;
D O I
10.1016/j.ejro.2024.100558
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Computed tomography pulmonary angiography (CTPA) is the gold standard diagnostic method for patients with suspected pulmonary embolism (PE), but it has its drawbacks, including exposure to ionizing radiation and iodinated contrast agent. The present study aims to evaluate the diagnostic performance of our inhouse developed non -contrast MRI protocol for PE diagnosis in reference to CTPA. Methods: 107 patients were included, all of whom underwent MRI immediately before or within 36 hours after CTPA. Additional cases examined only with MRI and a negative result were added to reach a PE prevalence of approximately 20%. The protocol was a non -contrast 2D steady-state free precession (SSFP) sequence under free -breathing, without respiratory or cardiac gating, and repeated five times to capture the vessels at different breathing/cardiac phases. The MRIs were blinded and read by two radiologists and the results were compared to CTPA. Results: Of the 243 patients included, 47 were positive for PE. Readers 1 and 2 demonstrated 89% and 87% sensitivity, 100% specificity, 98% accuracy and Cohen's kappa of 0.88 on patient level. In the per embolus comparison, readers 1 and 2 detected, 60 and 59/61 (98, 97%) proximal, 101 and 94/113 (89, 83%) segmental, and 5 and 2/32 (16, 6%) subsegmental emboli, resulting in 81 and 75% sensitivity respectively. Conclusion: The repeated 2D SSFP can reliably be used for the diagnosis of acute PE at the proximal and segmental artery levels.
引用
收藏
页数:8
相关论文
共 8 条
  • [1] Detection of pulmonary embolism using repeated MRI acquisitions without respiratory gating: a preliminary study
    Nyren, Sven
    Rogberg, Anna Nordgren
    Paris, Roberto Vargas
    Bengtsson, Bonnie
    Westerlund, Eli
    Lindholm, Peter
    ACTA RADIOLOGICA, 2017, 58 (03) : 272 - 278
  • [2] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    Li, Shuo
    Wang, Lei
    Zhu, Yan-Chun
    Yang, Jie
    Xie, Yao-Qin
    Fu, Nan
    Wang, Yi
    Gao, Song
    CHINESE PHYSICS B, 2016, 25 (12)
  • [3] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    李硕
    王磊
    朱艳春
    杨洁
    谢耀钦
    付楠
    王乙
    高嵩
    Chinese Physics B, 2016, 25 (12) : 547 - 552
  • [4] Diagnostic accuracy of magnetic resonance imaging for an acute pulmonary embolism: results of the IRM-EP' study
    Revel, M. P.
    Sanchez, O.
    Couchon, S.
    Planquette, B.
    Hernigou, A.
    Niarra, R.
    Meyer, G.
    Chatellier, G.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (05) : 743 - 750
  • [5] Detection of pulmonary nodules with move-during-scan magnetic resonance imaging using a free-breathing turbo inversion recovery magnitude sequence
    Baumann, Tobias
    Ludwig, Ute
    Pache, Gregor
    Gall, Christine
    Saueressig, Ulrich
    Fisch, Dagmar
    Stankovic, Zoran
    Bartholomae, Jean-Paul
    Honal, Matthias
    Bley, Thorsten Alexander
    Langer, Mathias
    Schaefer, Oliver
    INVESTIGATIVE RADIOLOGY, 2008, 43 (06) : 359 - 367
  • [6] Diagnostic accuracy of unenhanced and gadolinium-enhanced magnetic resonance imaging for acute pulmonary embolism diagnosis: results of the 'IRM-EP' study
    Sanchez, O.
    Revel, M-P
    Couchon, S.
    Planquette, B.
    Hernigou, A.
    Niarra, R.
    Lefort, C.
    Chatellier, G.
    Meyer, G.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 305 - 305
  • [7] Phase2Phase Respiratory Motion-Resolved Reconstruction of Free-Breathing Magnetic Resonance Imaging Using Deep Learning Without a Ground Truth for Improved Liver Imaging
    Eldeniz, Cihat
    Gan, Weijie
    Chen, Sihao
    Fraum, Tyler J.
    Ludwig, Daniel R.
    Yan, Yan
    Liu, Jiaming
    Vahle, Thomas
    Krishnamurthy, Uday
    Kamilov, Ulugbek S.
    An, Hongyu
    INVESTIGATIVE RADIOLOGY, 2021, 56 (12) : 809 - 819
  • [8] Layer-specific circumferential strain using fast strain-encoded cardiac magnetic resonance imaging in acute myocardial injury - a prospective study of diagnostic and prognostic accuracy
    Weberling, L. D.
    Albert, D.
    Ochs, A.
    Ochs, M.
    Siry, D.
    Salatzki, J.
    Giannitsis, E.
    Frey, N.
    Riffel, J.
    Andre, F.
    EUROPEAN HEART JOURNAL, 2023, 44