Quantitative assessment of intertarget position variations based on 4D-CT and 4D-CBCT simulations in single-isocenter multitarget lung stereotactic body radiation therapy

被引:0
|
作者
Zhang, Siyu [1 ]
Guo, Chang [1 ]
Xu, Jun [1 ]
Qian, Pudong [1 ]
Guo, Jiali [2 ]
Liu, Tingting [1 ]
Wu, Yifan [1 ]
Hong, Jun [3 ]
Wang, Qi [1 ]
He, Xia [1 ]
Sun, Li [1 ]
机构
[1] Nanjing Med Univ, Affiliated Canc Hosp, Dept Radiotherapy, Jiangsu Canc Hosp, Nanjing 210009, Peoples R China
[2] Dantu Peoples Hosp, Dept Radiat Oncol, Maanshan 243100, Anhui, Peoples R China
[3] Nanjing Med Univ, Dept Radiat Oncol, Affiliated Huaian Peoples Hosp 1, Huaian 223300, Jiangsu, Peoples R China
关键词
Intertarget position variation; Multiple targets; Lung SBRT; 4D-CBCT; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; MOTION; VARIABILITY; CANCER; RADIOTHERAPY; MARGINS; CT;
D O I
10.1007/s00432-024-05836-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundIn single-isocenter multitarget stereotactic body radiotherapy (SBRT), geometric miss risks arise from uncertainties in intertarget position. However, its assessment is inadequate, and may be interfered by the reconstructed tumor position errors (RPEs) during simulated CT and cone beam CT (CBCT) acquisition. This study aimed to quantify intertarget position variations and assess factors influencing it.MethodsWe analyzed data from 14 patients with 100 tumor pairs treated with single-isocenter SBRT. Intertarget position variation was measured using 4D-CT simulation to assess the intertarget position variations (Delta D) during routine treatment process. Additionally, a homologous 4D-CBCT simulation provided RPE-free comparison to determine the impact of RPEs, and isolating purely tumor motion induced Delta D to evaluate potential contributing factors.ResultsThe median Delta D was 4.3 mm (4D-CT) and 3.4 mm (4D-CBCT). Variations exceeding 5 mm and 10 mm were observed in 31.1% and 5.5% (4D-CT) and 20.4% and 3.4% (4D-CBCT) of fractions, respectively. RPEs necessitated an additional 1-2 mm safety margin. Intertarget distance and breathing amplitude variability showed weak correlations with variation (Rs = 0.33 and 0.31). The Delta D differed significantly by locations (upper vs. lower lobe and right vs. Left lung). Notably, left lung tumor pairs exhibited the highest risk.ConclusionsThis study provide a reliable way to assess intertarget position variation by using both 4D-CT and 4D-CBCT simulation. Consequently, single-isocenter SBRT for multiple lung tumors carries high risk of geometric miss. Tumor motion and RPE constitute a substantial portion of intertarget position variation, requiring correspondent strategies to minimize the intertarget uncertainties.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Evaluation of Accuracy of 4D-CT Scan in Lung Stereotactic Body Radiation Therapy
    Badkul, R. K.
    Pokhrel, D.
    Jiang, H.
    Wang, F.
    Kumar, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S67 - S67
  • [2] The assessment of consecutive 4D-CT scans during simulation for lung stereotactic body radiation therapy patients
    Savanovic, Milovan
    Strbac, Bojan
    Jaros, Drazan
    Foulquier, Jean-Noel
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (04): : 193 - 199
  • [3] Effect of respiratory motion on lung target volume during 4D-CT and 4D-CBCT imaging
    Liu, S.
    Liao, X.
    Li, J.
    Orlandini, L. C.
    Lang, J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S865 - S866
  • [4] Tumor motion at planning 4D-CT and treatment 4D-CBCT for a large cohort of lung SBRT targets
    Nielsen, T. B.
    Brink, C.
    Jeppesen, S. S.
    Schytte, T.
    Hansen, O.
    Nielsen, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S159 - S160
  • [5] Evaluation of the compatibility and accuracy of lung tumor ITV between 4D-CT and 4D-CBCT MIP images
    Tseng, Y.
    Zhang, M.
    Song, Y.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S951 - S951
  • [6] Low-cost versatile 4D lung phantom for QA of 4D-CT, 4D-CBCT, planning and dosimetry
    Franken, E.
    Lefeber, E.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S923 - S924
  • [7] Assessing the Validity of 4D-CT Based Target Volumes and Free Breathing CBCT Localization in Lung Stereotactic Ablative Radiation Therapy (SABR)
    Badkul, R.
    Pokhrel, D.
    Jiang, H.
    Park, J.
    Wang, F.
    Kumar, P.
    MEDICAL PHYSICS, 2014, 41 (06) : 204 - 205
  • [8] Four-dimensional CT (4D-CT) image guidance for stereotactic body radiation therapy (SBRT)
    Fuss, M.
    Srisuthep, A.
    Kalpathy-Cramer, J.
    D'Souza, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S440 - S440
  • [9] Implementation of 4D Cone beam CT (4D-CBCT) verification for the delivery of lung stereotactic ablative body radiotherapy in a UK radiotherapy centre
    Stamp, Alexander
    Pilling, Karen
    Hannan, Pierre
    Trainer, Michael
    Turnbull, Helen
    LUNG CANCER, 2025, 200
  • [10] 4D-CT Prediction of Inter- and Intrafraction Lung Tumor Motion During Fractionated Stereotactic Body Radiation Therapy
    Rashid, A.
    Niu, Y.
    Pang, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E947 - E947