Power harmonic analysis based on high-rate oversampling and windowed interpolation FFT

被引:0
|
作者
Zhang H. [1 ]
Xiong J. [1 ]
Cai X. [2 ]
机构
[1] College of Electrical Engineering, North China University of Water Resources and Electric Power, Zhengzhou
[2] School of Mechanical Engineering, Henan University of Engineering, Zhengzhou
关键词
correction; harmonic analysis; interpolation FFT; oversampling; quantization error; window function;
D O I
10.19783/j.cnki.pspc.230832
中图分类号
学科分类号
摘要
To improve the accuracy of harmonic analysis, the signal-to-noise ratio loss caused by signal windowing and the quantization error caused by AD conversion is analyzed, and the principle of improving signal-to-noise ratio by oversampling technology is expounded. A harmonic analysis method based on high-rate oversampling and windowed interpolation FFT is proposed. This method makes full use of the potential of an AD converter to take samples quickly, and at the same time, it avoids the surge of sampling data caused by high oversampling through mean filtering. The influence of the proposed method on the amplitude and phase of harmonic components in the signal is studied in detail, and a concise and practical correction method of harmonic amplitude and phase is given. Simulation results show that the proposed method can improve the anti-noise ability of windowed interpolation FFT and the accuracy of harmonic analysis without increasing system cost. © 2024 Power System Protection and Control Press. All rights reserved.
引用
收藏
页码:105 / 115
页数:10
相关论文
共 25 条
  • [1] WANG Y, TANG J, SI J, Et al., Power quality enhancement in islanded microgrids via closed-loop adaptive virtual impedance control, Protection and Control of Modern Power Systems, 8, 1, pp. 163-179, (2023)
  • [2] LI Qian, LEI Chengcheng, LIU Xia, Analysis of harmonic detection methods in power system research status, Telecom Power Technology, 34, 5, pp. 85-86, (2017)
  • [3] ZHOU Qun, GUAN Zichao, MA Xiaoyang, Et al., High precision harmonic detection in non-synchronous sampling based on an embedded system, Power System Protection and Control, 51, 9, pp. 138-146, (2023)
  • [4] QING Baiyuan, TENG Zhaosheng, GAO Yunpeng, Et al., An approach for electrical harmonic analysis based on Nuttall window double-spectrum-line interpolation FFT, Proceedings of the CSEE, 28, 25, pp. 153-158, (2008)
  • [5] NIU Shengsuo, LIANG Zhirui, ZHANG Jianhua, Et al., An algorithm for electrical harmonic analysis based on triple-spectrum-line interpolation FFT, Proceedings of the CSEE, 32, 16, pp. 130-136, (2012)
  • [6] LI Demin, HE Yigang, Harmonic analysis of power system based on Nuttall window four-spectrum-line interpolation FFT, Power System Protection and Control, 44, 3, pp. 64-71, (2016)
  • [7] HUA Min, CHEN Jianyun, A high precision approach for harmonic and interharmonic analysis based on six-spectral-line interpolation FFT, Power System Protection and Control, 47, 11, pp. 9-15, (2019)
  • [8] HUANG Xingyu, LUO Pingping, GONG Jinxia, Et al., Subsynchronous harmonic phasor detection in a renewable energy grid-connected system, Power System Protection and Control, 48, 13, pp. 38-44, (2020)
  • [9] WEN He, TENG Zhaosheng, QING Baiyuan, Hanning self-convolution windows and its application to harmonic analysis, Transactions of China Electrotechnical Society, 24, 2, pp. 164-169, (2009)
  • [10] LIU Dongmei, YANG Zhongliang, ZHANG Yan, Et al., Harmonic analysis of power system based on Nuttall self-convolution window four-spectral-line interpolation FFT, Journal of Hefei University of Technology (Natural Science), 41, 1, pp. 12-17, (2018)