Comparison of long-term clinical outcomes of bioabsorbable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis

被引:1
|
作者
Rehman, Abdur [1 ]
Ahmed, Ifra Eeman [2 ]
Nouman, Ahmed [1 ]
Irfan, Rabia [3 ]
Rehman, Qareeha [3 ]
Syed, Abdul Rehman Shah [4 ]
Zakir, Syeda Javeria [4 ]
Mehdi, Samar [1 ]
Khosa, Maha Mushtaq [5 ]
Kumar, Satesh [6 ]
Khatri, Mahima [4 ]
Samiullah, F. N. U. [6 ]
Mohamad, Tamam [7 ]
Varrassi, Giustino [8 ]
机构
[1] Shaikh Zayed Hosp, Dept Med, Lahore, Pakistan
[2] Fed Med & Dent Coll, Islamabad, Pakistan
[3] Fed Med & Dent Coll, Rawalpindi, Pakistan
[4] Dow Univ Hlth Sci Med, Karachi, Pakistan
[5] Quetta Inst Med Sci, Quetta, Pakistan
[6] Shaheed Mohtarma Benazir Bhutto Med Coll, Dept Med, Karachi, Pakistan
[7] Wayne State Univ, Detroit, MI USA
[8] Paolo Procacci Fdn PPF, Rome, Italy
来源
EGYPTIAN HEART JOURNAL | 2024年 / 76卷 / 01期
关键词
Bioabsorbable polymer BP; Durable polymer DP; Drug-eluting stent; CORONARY-ARTERY-DISEASE; FINAL 5-YEAR REPORT; BIODEGRADABLE-POLYMER; BARE-METAL; THROMBOSIS; TRIAL; MULTICENTER; SAFETY;
D O I
10.1186/s43044-024-00522-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundOne million individuals in the USA die from acute myocardial infarction (MI), which currently affects 3 million people globally. The available data about the early and late outcomes of both biodegradable polymer drug-eluting stents (BP-DES) and durable polymer drug-eluting stents exhibit inconsistency. We performed a meta-analysis comparing the safety and efficacy of BP-DES with DP-DES. MethodsPubMed, Google Scholar, EMBASE, Cochrane, Ovid Medline, and Clinical Trials.gov databases were used to find out studies comparing BP-DES to DP-DES. All the analyses used the random-effects model. ResultsA total of 18 studies were incorporated in this meta-analysis that involved 28,874 patients, out of which 11,997 received the BP Stent, and the rest of 16,578 received the DP stent. Thorough analyses revealed that the risk of all-cause death was significantly higher in the BP-DES group (5.4% vs 2.7%) (RR 1.22, p 0.02) for two years or less than two-year follow-up. For studies with more than two years of follow-up, all-cause death was 9.07% (599/6603) in BP-DES and 9.47% (531/5602) in the DP-DES group but failed to achieve statistically significant levels (RR 0.97, p 0.58). ConclusionsThe study revealed no clinically significant (P value was > 0.05) differences in all-cause death, cardiac death, target lesion revascularization (TLR), late stent thrombosis, device-oriented composite endpoint/target lesion failure (DOCE/TLF), myocardial infarction (MI), target vessel MI, target vessel revascularization (TVR), target vessel infarction (TVI) between BP-DES and DP-DES for more than two years of follow-up. Additionally, all-cause death was only outcomes which found to have a statistically significant difference for less than two years of follow-up, while remaining were statistically non-significant.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A meta-analysis of randomized controlled trials to compare long-term clinical outcomes of bioabsorbable polymer and durable polymer drug-eluting stents
    Mridha, Naim
    Subhaharan, Deloshaan
    Niranjan, Selvanayagam
    Rashid, Mohammed K.
    Psaltis, Peter
    Singh, Kuljit
    EUROPEAN HEART JOURNAL-QUALITY OF CARE AND CLINICAL OUTCOMES, 2019, 5 (02) : 105 - 113
  • [2] Comparison of the safety and efficacy of biodegradable polymer drug-eluting stents versus durable polymer drug-eluting stents: a meta-analysis
    Lv, Jianfeng
    Wu, Yazhou
    Zhang, Xingmei
    Jing, Tao
    Zhang, Li
    Tong, Shifei
    Song, Zhiyuan
    Wang, Mingli
    Wang, Gang
    Chi, Luxiang
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2015, 20
  • [3] Comparison of the safety and efficacy of biodegradable polymer drug-eluting stents versus durable polymer drug-eluting stents: a meta-analysis
    Jianfeng Lv
    Yazhou Wu
    Xingmei Zhang
    Tao Jing
    Li Zhang
    Shifei Tong
    Zhiyuan Song
    Mingli Wang
    Gang Wang
    Luxiang Chi
    European Journal of Medical Research, 20
  • [4] VERY LONG-TERM CLINICAL OUTCOMES FOLLOWING IMPLANTATION OF BIODEGRADABLE POLYMER VERSUS DURABLE POLYMER DRUG-ELUTING STENT: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Suzuki, Satoshi
    Sotomi, Yohei
    Suwannsom, Pannipa
    Kobayashi, Tomoaki
    Hirayama, Atsushi
    Higuchi, Yoshiharu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1061 - 1061
  • [5] Long-term safety of ultrathin bioabsorbable-polymer sirolimus-eluting stents versus thin durable-polymer drug-eluting stents in acute coronary syndrome: A systematic review and meta-analysis
    Li, Fadong
    Wang, Shen
    Wang, Yue
    Wei, Can
    Liu, Xinyan
    Sun, Shuaifeng
    Zhao, Wenxin
    Guo, Pengrong
    Wu, Xiaofan
    CLINICAL CARDIOLOGY, 2023, 46 (12) : 1465 - 1473
  • [6] A meta-analysis of randomized controlled trials to compare long-term clinical outcomes of bioabsorbable polymer and durable polymer drug-eluting stents (vol 5, pg 105, 2019)
    Mridha, Naim
    Subhaharan, Deloshaan
    Niranjan, Selvanayagam
    Rashid, Mohammed K.
    Psaltis, Peter
    Singh, Kuljit
    EUROPEAN HEART JOURNAL-QUALITY OF CARE AND CLINICAL OUTCOMES, 2019, 5 (01) : 82 - 82
  • [7] COMPARISON OF LONG-TERM OUTCOMES WITH BIODEGRADABLE POLYMER DRUG ELUTING STENTS AND DURABLE POLYMER DRUG ELUTING STENTS: AN UPDATED META-ANALYSIS OF RANDOMIZED CONTROLLED TRIALS
    Tripathi, Byomesh
    Kost, Michael
    Ashukem, Moses
    Marchbanks, Katheryne
    Biglari, David
    Sugumaran, Rajkumar
    Centorino, Ligita
    Gramze, Nickalaus
    Mehr, Ali
    Arabia, Francisco
    Su, Wilber
    Kalya, Anantharam
    Banday, Arshad
    Abbas, Firas
    Butman, Samuel
    Patel, Nachiket
    Weiss, Peter
    Hurst, Robert
    Freiman, Samuel Unzek
    Gulati, Martha
    Gopalan, Radha
    Verma, Divya Ratan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1460 - 1460
  • [8] Long-term outcomes of biodegradable versus 2nd generation durable polymer drug-eluting stents in PCI: Protocol for a systematic review and meta-analysis
    Thuemmler, Rosa J.
    Choudhary, Trisha
    Tan, Yong Hui
    Andrei, Maria-Bianca
    Liu, Haipeng
    Kumar, Niraj S.
    PLOS ONE, 2025, 20 (03):
  • [9] Biodegradable-Polymer Drug-Eluting Stents versus Bare Metal Stents versus Durable-Polymer Drug-Eluting Stents : A Systematic Review and Bayesian Approach Network Meta-Analysis
    Kang, Si-Hyuck
    Park, Kyung Woo
    Kang, Do-Yoon
    Lim, Woo-Hyun
    Park, Kyung Taek
    Han, Jung-Kyu
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Oh, Byung-Hee
    Park, Young-Bae
    Kandzari, David
    Cohen, David
    Hwang, Seung-Sik
    Kim, Hyo-Soo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B251 - B251
  • [10] Biodegradable polymer drug-eluting stents versus first-generation durable polymer drug-eluting stents A systematic review and meta-analysis of 12 randomized controlled trials
    Bundhun, Pravesh Kumar
    Pursun, Manish
    Huang, Feng
    MEDICINE, 2017, 96 (47)