Quantitative Analysis of Uranium in Gas Sampling Filter by Laser-induced Breakdown Spectroscopy

被引:0
|
作者
Wang X. [1 ]
Wang Y. [1 ]
Gao Z. [1 ]
Cheng Y. [1 ]
Si Y. [1 ]
机构
[1] Department of Radiochemistry, China Institute of Atomic Energy, Beijing
关键词
Gas sampling filter; Laser-induced breakdown spectroscopy; Quantitative analysis; Uranium;
D O I
10.7538/yzk.2021.youxian.0038
中图分类号
学科分类号
摘要
For nuclear facility exhaust gas monitoring, it is necessary to measure and analyze the concentration of uranium in the gas sampling filter. In this paper, the reasearch of laser-induced breakdown spectroscopy (LIBS) quantitative analysis technology basing on calibration curve was carried out. By analyzing the filters containing uranium by using LIBS technology, the effective characteristic spectrum of uranium was selected after optimizing the delay time parameter, and quantitative calibration curves within a relatively lower concentration range were obtained. The verification research results show that, under the optimized experimental conditions, the bias of measurement is less than 20%, and the RSD is less than 10%. © 2022, Editorial Board of Atomic Energy Science and Technology. All right reserved.
引用
收藏
页码:9 / 14
页数:5
相关论文
共 17 条
  • [1] MOMOSHIMA N., Identification of the contamination source of plutonium in environmental samples with isotopic ratios determined by inductively coupled plasma mass spectrometry and alpha-spectrometry, Journal of Radioanalytical and Nuclear Chemistry, 221, pp. 213-217, (1997)
  • [2] VARGA Z., Improved sample preparation method for environmental plutonium analysis by ICP-SFMS and alpha-spectrometry, Journal of Radioanalytical and Nuclear Chemistry, 274, pp. 87-94, (2007)
  • [3] (2006)
  • [4] EGLE B J, HART K J, AARON W S., Stable isotope enrichment capabilities at Oakridge National Laboratory, J Radioanal Nucl Chem, 299, pp. 995-999, (2014)
  • [5] JOBBAGY V, CRESPO M T, AMMEL R V, Et al., Preparation of high-resolution <sup>238</sup>U alpha sources by electrodeposition: A com-prehensive study, J Radioanal Nucl Chem, 298, pp. 345-352, (2013)
  • [6] (2014)
  • [7] FICHET P, MAUCHIEN P, MOULIN C., Determination of impurities in uranium and plutonium dioxides by laser-induced breakdown spectroscopy, Appl Spectrosc, 53, pp. 1111-1117, (1999)
  • [8] PIETSCH W, PETIT A, BRIAND A., Isotope ratio determination of uraniumby optical emission spectroscopy on a laser-produced plasma: Basic investigations and analytical results, Spectrochim Acta B, 53, pp. 751-761, (1998)
  • [9] SMITH C A, MARTINEZ M A, VEIRS D K, Et al., Pu-239/Pu-240 isotope ratios determined using high resolution emission spectroscopy in a laser-induced plasma, Spectrochim Acta B, 57, pp. 929-937, (2002)
  • [10] SHEN X K, LU Y F., Detection of uranium in solids by using laser-induced breakdown spectroscopy combined with laser-induced fluorescence, Appl Opt, 47, pp. 1810-1815, (2008)