摘要
In order to cope with the potential failure risk of energy supply equipment in an integrated energy system, an equipment failure probability model based on operating conditions and an equipment failure severity model based on load ratios are established, characterizing the relationship between different operating conditions of equipment and system safety risks. An IES multi-objective optimization operation model is established by taking the operating cost and risk as the optimization objectives, considering comprehensively different constraints of a power network, natural gas pipeline networks, thermal pipeline networks, unit output, etc. Then, the model is processed into a mixed-integer second-order cone programming model using the second-order cone relaxation, piecewise linearization and tolerant hierarchical sequence method, and the tolerance is used to characterize the system's acceptance of risk. The analysis of a calculated example shows that the operating strategy derived from the model can take into account the safety and economy of the system. This verifies the rationality and effectiveness of the model and method. © 2022 Power System Protection and Control Press. All rights reserved.
引用
收藏
页码:34 / 44
页数:10
相关论文
共 30 条
  • [1] HU Hao, WANG Yingrui, ZENG Bo, Et al., CVaR-based economic optimal dispatch of integrated energy system, Electric Power Automation Equipment, 37, 6, pp. 209-219, (2017)
  • [2] SHEN Chen, JIA Mengshuo, CHEN Ying, Et al., Digital twin of the energy internet and its application, Journal of Global Energy Interconnection, 3, 1, pp. 1-13, (2020)
  • [3] QU Xiaoyun, WU Ming, LI Qi, Et al., Review on comprehensive evaluation of multi-energy complementary integrated energy systems, Electric Power, 54, 11, pp. 153-163, (2021)
  • [4] YANG Fang, HE Xiaoping, Power shortage in Taiwan—base on the analysis of their power supply and demand, Taiwan Research Journal, 3, pp. 40-51, (2019)
  • [5] GAO Qiang, LIU Chang, JIN Daojie, Et al., Optimal configuration of park-level integrated energy system considering integrated demand response, High Voltage Apparatus, 57, 8, pp. 159-168, (2021)
  • [6] HUANG Jingguang, WANG Tan, LIN Xiangning, Et al., Robust optimal dispatch of regional integrated energy system for wind power consumption, Electrical Measurement & Instrumentation, 58, 12, pp. 110-117, (2021)
  • [7] MEI Jianchun, WEI Zhinong, ZHANG Yong, Et al., Hybrid control of integrated power and gas energy systems based on significant contingency screening, Power System Technology, 43, 1, pp. 23-33, (2019)
  • [8] PAN Yi, MEI Fei, ZHENG Jianyong, Et al., Operation optimization model for multi-integrated energy systems considering static security and optimal energy flow, Power System Technology, 43, 1, pp. 50-59, (2019)
  • [9] FU Xu, Static security preventive control considering uncertainty factor for power system, Electric Power Automation Equipment, 34, 2, pp. 120-124, (2014)
  • [10] JIANG Donglin, XU Xiangdong, LIU Tianqi, Et al., Security-constrained optimal power flow of power grid connected with wind farms considering corrective control, Power System Technology, 37, 1, pp. 172-177, (2013)