Efficacy and Safety of Continuous Glucose Monitoring and Intermittently Scanned Continuous Glucose Monitoring in Patients With Type 2 Diabetes: A Systematic Review and Meta-analysis of Interventional Evidence

被引:21
|
作者
Seidu, Samuel [1 ,2 ]
Kunutsor, Setor K. [1 ,2 ]
Ajjan, Ramzi A. [3 ]
Choudhary, Pratik [1 ,2 ]
机构
[1] Univ Leicester, Natl Inst Hlth Res, Diabet Res Ctr, Appl Res Collaborat East Midlands, Leicester, England
[2] Univ Leicester, Leicester Gen Hosp, Natl Inst Hlth Res, Diabet Res Ctr,Biomed Res Ctr, Leicester, England
[3] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Clin Populat & Sci Dept, Leeds, England
关键词
D O I
10.2337/dc23-1520
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Traditional diabetes self-monitoring of blood glucose (SMBG) involves inconvenient finger pricks. Continuous glucose monitoring (CGM) and intermittently scanned CGM (isCGM) systems offer CGM, enhancing type 2 diabetes (T2D) management with convenient, comprehensive data. PURPOSE To assess the benefits and potential harms of CGM and isCGM compared with usual care or SMBG in individuals with T2D. DATA SOURCES We conducted a comprehensive search of MEDLINE, Embase, the Cochrane Library, Web of Science, and bibliographies up to August 2023. STUDY SELECTION We analyzed studies meeting these criteria: randomized controlled trials (RCT) with comparison of at least two interventions for >= 8 weeks in T2D patients, including CGM in real-time/retrospective mode, short-/long-term CGM, isCGM, and SMBG, reporting glycemic and relevant data. DATA EXTRACTION We used a standardized data collection form, extracting details including author, year, study design, baseline characteristics, intervention, and outcomes. DATA SYNTHESIS We included 26 RCTs (17 CGM and 9 isCGM) involving 2,783 patients with T2D (CGM 632 vs. usual care/SMBG 514 and isCGM 871 vs. usual care/SMBG 766). CGM reduced HbA1c (mean difference -0.19% [95% CI -0.34, -0.04]) and glycemic medication effect score (-0.67 [-1.20 to -0.13]), reduced user satisfaction (-0.54 [-0.98, -0.11]), and increased the risk of adverse events (relative risk [RR] 1.22 [95% CI 1.01, 1.47]). isCGM reduced HbA1c by -0.31% (-0.46, -0.17), increased user satisfaction (0.44 [0.29, 0.59]), improved CGM metrics, and increased the risk of adverse events (RR 1.30 [0.05, 1.62]). Neither CGM nor isCGM had a significant impact on body composition, blood pressure, or lipid levels. LIMITATIONS Limitations include small samples, single-study outcomes, population variations, and uncertainty for younger adults. Additionally, inclusion of <10 studies for most end points restricted comprehensive analysis, and technological advancements over time need to be considered. CONCLUSIONS Both CGM and isCGM demonstrated a reduction in HbA1c levels in individuals with T2D, and unlike CGM, isCGM use was associated with improved user satisfaction. The impact of these devices on body composition, blood pressure, and lipid levels remains unclear, while both CGM and isCGM use were associated with increased risk of adverse events.
引用
收藏
页码:169 / 179
页数:12
相关论文
共 50 条
  • [2] Response to Comment on Seidu et al. Efficacy and Safety of Continuous Glucose Monitoring and Intermittently Scanned Continuous Glucose Monitoring in Patients With Type 2 Diabetes: A Systematic Review and Meta-analysis of Interventional Evidence. Diabetes Care 2024;47:169-179
    Seidu, Samuel
    Kunutsor, Setor K.
    DIABETES CARE, 2024, 47 (07) : e52 - e53
  • [3] Adherence to glucose monitoring with intermittently scanned continuous glucose monitoring in patients with type 1 diabetes
    Carolina Sousa
    João Sérgio Neves
    Cláudia Camila Dias
    Rute Sampaio
    Endocrine, 2023, 79 : 477 - 483
  • [4] Adherence to glucose monitoring with intermittently scanned continuous glucose monitoring in patients with type 1 diabetes
    Sousa, Carolina
    Neves, Joao Sergio
    Dias, Claudia Camila
    Sampaio, Rute
    ENDOCRINE, 2023, 79 (03) : 477 - 483
  • [5] Intermittently Scanned Continuous Glucose Monitoring for Type 1 Diabetes
    Leelarathna, Lalantha
    Evans, Mark L. L.
    Neupane, Sankalpa
    Rayman, Gerry
    Lumley, Sarah
    Cranston, Iain
    Narendran, Parth
    Barnard-Kelly, Katharine
    Sutton, Christopher J. J.
    Elliott, Rachel A. A.
    Taxiarchi, Vicky P. P.
    Gkountouras, Georgios
    Burns, Matthew
    Mubita, Womba
    Kanumilli, Naresh
    Camm, Maisie
    Thabit, Hood
    Wilmot, Emma G. G.
    NEW ENGLAND JOURNAL OF MEDICINE, 2022, 387 (16): : 1477 - 1487
  • [6] Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
    Milena Jancev
    Tessa A. C. M. Vissers
    Frank L. J. Visseren
    Arianne C. van Bon
    Erik H. Serné
    J. Hans DeVries
    Harold W. de Valk
    Thomas T. van Sloten
    Diabetologia, 2024, 67 : 798 - 810
  • [7] Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
    Jancev, Milena
    Vissers, Tessa A. C. M.
    Visseren, Frank L. J.
    van Bon, Arianne C.
    Serne, Erik H.
    DeVries, J. Hans
    de Valk, Harold W.
    van Sloten, Thomas T.
    DIABETOLOGIA, 2024, 67 (05) : 798 - 810
  • [8] The Effectiveness of Continuous Glucose Monitoring in Patients with Type 2 Diabetes: A Systematic Review of Literature and Meta-analysis
    Park, Cindy
    Le, Quang A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (09) : 613 - 621
  • [9] Use of intermittently scanned continuous glucose monitoring in gestational diabetes
    Alington, K.
    Cranston, I. C.
    Cummings, M. H.
    DIABETIC MEDICINE, 2023, 40
  • [10] Efficacy and safety of continuous glucose monitoring systems vs self-monitoring blood glucose in patients with type 1 diabetes mellitus: a systematic review and meta-analysis
    Rys, P.
    Mucha, A.
    Koprowski, M.
    Nowicki, M.
    Malecki, M. T.
    DIABETOLOGIA, 2011, 54 : S116 - S116