Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device

被引:21
|
作者
Lodge, Clare [1 ,3 ]
Tobin, Diarmuid [1 ]
O'Rourke, Brian [1 ]
Thorborg, Kristian [2 ]
机构
[1] Inst Technol Carlow, Dept Sci & Hlth, Carlow, Ireland
[2] Univ Copenhagen, Fac Hlth Sci, Hvidovre, Denmark
[3] Inst Technol Carlow, Dept Sci & Hlth, Kilkenny Rd, Carlow, Ireland
关键词
Clinical decision-making; Hamstring muscles; Rehabilitation; SOCCER PLAYERS; EXERCISE; INJURIES;
D O I
10.1016/j.arrct.2019.100034
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device.Design: A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device.Setting: Institute of Technology Carlow, third level educational institution.Participants: Male intercollegiate field-sport players completed the trial (N=19). Participants were 21 +/- 2 years, weighed 78.6 +/- 4.6 kg, and were 179.6 +/- 6.4 cm in height. Interventions: N/A.Main Outcome Measures: Peak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device.Results: High test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)= .910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC% = 14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively.Conclusion(s): The new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management.(c) 2019 The Authors. Published by Elsevier Inc. on behalf of the American Congress of Rehabil-itation Medicine. This is an open access article under the CC BY-NC-ND license (http:// creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Reliability And Validity Of A Novel Field Testing Device To Assess Eccentric Hamstring Strength
    Opar, David
    Williams, Morgan
    Piatkowski, Timothy
    Shield, Anthony
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 431 - 431
  • [2] Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility
    Muyor, Jose M.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2017, 38 (09) : 691 - 695
  • [3] The Validity of the Nordic Hamstring Lower for a Field-Based Assessment of Eccentric Hamstring Strength
    Sconce, Emma
    Jones, Paul
    Turner, Ellena
    Comfort, Paul
    Graham-Smith, Philip
    JOURNAL OF SPORT REHABILITATION, 2015, 24 (01) : 13 - 20
  • [4] Reliability, Validity, and Sensitivity of a Novel Smartphone-Based Eccentric Hamstring Strength Test in Professional Football Players
    Lee, Justin W. Y.
    Cai, Ming-Jing
    Yung, Patrick S. H.
    Chan, Kai-Ming
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2018, 13 (05) : 620 - 624
  • [5] Validity and reliability of a new ankle dorsiflexion measurement device
    Gatt, Alfred
    Chockalingam, Nachiappan
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2013, 37 (04) : 289 - 297
  • [6] Reliability of the Hip Extension Lower Exercise as a Measure of Eccentric Hamstring Strength
    O'Brien, Joey
    Browne, Declan
    Earls, Des
    Lodge, Clare
    BIOMECHANICS, 2022, 2 (01): : 1 - 6
  • [7] Validity and reliability of a new in vivo ankle stiffness measurement device
    Zinder, Steven M.
    Granata, Kevin P.
    Padua, Darin A.
    Gansneder, Bruce M.
    JOURNAL OF BIOMECHANICS, 2007, 40 (02) : 463 - 467
  • [8] Measurement of hip extension strength with a portable device: Description, reliability and validity of a procedure
    Bohannon, Richard W.
    Chu, Johnson
    Portz, Megan
    ISOKINETICS AND EXERCISE SCIENCE, 2015, 23 (04) : 271 - 274
  • [9] A Novel Device Using the Nordic Hamstring Exercise to Assess Eccentric Knee Flexor Strength: A Reliability and Retrospective Injury Study
    Opar, David A.
    Piatkowski, Timothy
    Williams, Morgan D.
    Shield, Anthony J.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2013, 43 (09): : 636 - 640
  • [10] Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord)
    Akarcesme, Cengiz
    Cengizel, Elif
    Alvurdu, Sumer
    Bagci, Emre
    Altundag, Emre
    Cengizel, Cagdas Ozgur
    Senel, Omer
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2024,