Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation

被引:0
|
作者
Scattergood, S. D. [1 ]
Berry, A. L. [1 ]
Flannery, O. [1 ]
Burdon, A. [2 ]
Mitchell, S. R. [1 ]
Fletcher, J. W. A. [1 ,3 ]
机构
[1] Bristol Royal Infirm & Gen Hosp, Dept Trauma & Orthopaed, Bristol, England
[2] Univ Bath, Dept Math Sci, Bath, England
[3] Univ Bath, Dept Hlth, Bath, England
关键词
Neck of femur fracture; Hip Fracture; Intracapsular; Cannulated screws; Avascular necrosis; INTERNAL-FIXATION; HIP-FRACTURES; RISK-FACTORS; HEMIARTHROPLASTY; COMPLICATIONS; ARTHROPLASTY; METAANALYSIS; REPLACEMENT; LONG; KNEE;
D O I
10.1007/s00590-024-03956-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Cannulated screw fixation for femoral neck fractures is often limited by concerns of avascular necrosis (AVN) occurring, historically seen in 5-40% of fixed intracapsular fractures. This study aims to assess the outcomes, particularly the AVN rate, associated with current surgical techniques within our unit.Methods We conducted a single-center cross-sectional study, manually searching operative records between July 14, 2014, and December 1, 2018, identifying patients with intracapsular fractured neck of femur fixed with cannulated screws, with a minimum of two years follow-up. Patient records and radiographs were reviewed for clinical and radiographic diagnoses of AVN, non-union, post-operative metalwork infection, and screw penetration of the head. Additionally, fracture pattern and displacement, screw configuration, reduction techniques, and adequacy of reduction were recorded, with radiographs independently analyzed by four orthopedic surgeons.Results Fifty-six patients were included; average age of 67 years (range 30-100). Forty-two patients (75%) sustained displaced fractures and 14 patients (25%) had undisplaced fractures. Two (4%) patients developed AVN, with no cases of non-union, post-operative metalwork infection or screw penetration of the head. Eight patients (14%) sustained a high-energy injury, though none of these patients developed AVN. All fractures required closed reduction; no open reductions performed. Twenty-seven (64%) of reductions were adequate.Conclusion Our observed AVN rate is notably lower than the widely reported figures, even among a significant proportion of displaced fractures that were fixed. This study underscores that with adequate fixation, cannulated screws represent an excellent option for treating intracapsular neck of femur fractures, even in cases of displaced fracture patterns with imperfect reduction.
引用
收藏
页码:2565 / 2571
页数:7
相关论文
共 50 条
  • [1] Multiple cannulated screw fixation of young femoral neck fractures
    Kim, Joo Yong
    Kong, Gyu Min
    Park, Dae Hyun
    Kim, Dae Yoo
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2015, 31 (06) : 1517 - 1520
  • [2] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975
  • [3] A predictive method for subsequent avascular necrosis of the femoral head (AVNFH) by observation of bleeding from the cannulated screw used for fixation of intracapsular femoral neck fractures
    Cho, Myung-Rae
    Lee, Sang-Wook
    Shin, Dong-Kyu
    Kim, Shin-Kun
    Kim, Shin-Yoon
    Ko, Sang-Bong
    Kwun, Koing-Woo
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) : 158 - 164
  • [4] Should a low starting point be abandoned for cannulated screw fixation of femoral neck fractures?
    Wodarek, Jeremy
    Ostrander, James
    Atkinson, Patrick
    Atkinson, Theresa
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [5] INTRACAPSULAR FRACTURES OF THE FEMORAL-NECK - RESULTS OF CANNULATED SCREW FIXATION
    ASNIS, SE
    WANEKSGAGLIONE, L
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (12): : 1793 - 1803
  • [6] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [7] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Zhang, Baokun
    Liu, Jingwen
    Zhu, Yi
    Zhang, Wei
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1949 - 1955
  • [8] Percutaneous cannulated screw fixation of femoral neck fractures: The three point principle
    Bout, CA
    Cannegieter, DM
    Juttmann, JW
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (02): : 135 - 139
  • [9] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Baokun Zhang
    Jingwen Liu
    Yi Zhu
    Wei Zhang
    International Orthopaedics, 2018, 42 : 1949 - 1955
  • [10] Intramedullary nails with cannulated screw fixation for the treatment of unstable femoral neck fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Bing
    Jin, Lin
    Lin, Zhe
    Hou, Zhiyong
    Zhang, Yingze
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) : 557 - 568